Chapter 3. Test Modes
3-2
DSU 56/64 User Manual
61200062L1-1
If an
E
PROM
C
HECKSUM
failure is detected during self test,
CS
,
ALM
,
PTRN
, and
E
RROR
indicators all flash at the end of the self
test.
NEAR END TESTS
The local DSU 56/64 can perform the following near end tests:
•
DTE Only
•
DTE with Test Pattern
•
DTE and LOOP (LL)
•
Loop Only (RT)
DTE ONLY TEST
The
DTE O
NLY
test can test both the DTE interface of the local DSU
56/64 plus its loop transmitter and receiver. For this test, the loop
transmit data is connected to the loop receive data at a point close
to the physical network interface.
The loopback point and the signal paths for this test are shown in
Figure 3-1.
Figure 3-1. DTE Only Test Diagram
56/64 DSU
DTE
Receive
Interface
DTE
Transmit
Interface
Loop
Transmit
Interface
Loop
Receive
Interface
DTE
Only
TD
DTE or Test
Equipment
Interface
Network
Interface
RD
Loop TX
Loop RX
Summary of Contents for DSU 56/64
Page 1: ...DSU 56 64 Data Service Unit User Manual Part Number 1200062L1 61200062L1 1E May 2001...
Page 16: ...List of Figures xvi DSU 56 64 User Manual 61200062L1 1...
Page 18: ...List of Tables xviii DSU 56 64 User Manual 61200062L1 1...
Page 28: ...Chapter 2 Installation 2 6 DSU 56 64 User Manual 61200062L1 1...
Page 38: ...Chapter 3 Test Modes 3 10 DSU 56 64 User Manual 61200062L1 1...