    5

Signal Relay Replacement

Each loop has a cut-through signal relay accessible on 
the backplane. The relay ensures data transfer in the 
event the NIU3 card fails, is removed, or loses power. 
Failure of the relay is determined by process of elimi-
nation. If a loss of signal occurs, and all other param-
eters are satisfactory, then a failed relay is indicated. A 
relay replacement kit (P/N 1212072L1) is available 
from ADTRAN.

CAUTION

Observe prong configuration on the removed
relay. Relays are polarity sensitive, and
replacement relays must be oriented correctly.

Follow this procedure to replace a failed signal relay:

1. Insert a jumper strap on the posts immediately 

adjacent to the suspect relay. This provides a signal 
path bypassing the relay.

2. Using an appropriately-sized IC extractor tool, lift 

the relay off its socket.

3. Align and insert the replacement relay, taking care 

not to bend prongs, and that relay orientation is the 
same as the removed relay.

4. Remove the jumper strap.
5. Observe normal operation.

Alarm Relay Replacement

The alarm relay is located adjacent to the alarm wire-
wrap pins on the backplane. The alarm relay output 
responds to the card malfunction status on individual 
NIU3 cards. If an alarm condition occurs, but an alarm 
signal is not present, then a failed alarm relay is 
indicated. Follow this procedure to replace a failed 
alarm relay:

1. Using an appropriately-sized IC extractor tool, lift 

the relay off its socket.

2. Align and insert the replacement relay, taking care 

not to bend prongs, and that relay orientation is the 
same as the removed relay.

8. SPECIFICATIONS

 See 

Table 2

 for shelf specifications. 

Table 2.  DS3 NIU3 3-Slot Shelf Specifications

Environmental

Operating Temperature

Storage Temperature

Relative Humidity

–40°C to 70°C
 (–40°F to 158°F)
–40°C to 85°C
 (–40°F to 185°F)
Per GR-63

Physical

Dimensions

Weight

17.5 in. W
7.0 in. D
1.75 in. H
T400 density
12 lb. w/3 NIU3 cards

Power

Volts

Max input current

–48 VDC or ±24 VDC
(nominal)
0.375 A or 0.750 A
(fully loaded)

Compliance

NEBS

UL

FCC

ANSI

Level 3
60950
Part 15, Class A
T1.404

Part Numbers

DS3 NIU3 3-Slot Shelf

NIU3

Blank slot cover

Power Supply/Rectifier

Relay Replacement Kit

(1 Alarm Relay, 2 Signal
Relays, 2 Jumper Straps)

Wallmount Brackets:

3-Slot Shelf

12-Slot Shelf

1212073L1
CLEI: NCM5K4ZD _ _
1213075L2
CLEI: NCD3EGRA _ _
1212076L1
1212080L1
1212072L1

1212073L1WM
1212078L1WM

Summary of Contents for DS3 NIU3

Page 1: ...he backplane circuitry is protected by a metal cover that has openings for BNC data jacks pass through relays power terminal connections and alarm pins Removable covers provide security for power and alarm connections and pass through and alarm relays All connections are clearly labeled Features The NIU3 3 Slot Shelf provides the following features and functions Field replaceable pass through rela...

Page 2: ...212078L1WM accommo dates a stack of two 3 Slot Chassis Six x inch bladed hex head screws and flat washers are provided with the 1212078L1WM wallmount bracket for attaching to the wall In this configuration the original flanges are removed and the wallmount flanges are installed using the countersink screws from the originals If using P N 1212073L1WM install the chassis so the circuit cards front p...

Page 3: ... local supply to PWR A 2 Connect the associated return wire to RET A 3 If redundant power is intended make similar connections to PWR B and RET B CAUTION Terminate grounds to an approved ground location Check metal to metal contact on all ground connections Verify ground circuit continuity 4 Connect the common frame ground terminal or ground lug 6 AWG max to an approved ground location CAUTION Per...

Page 4: ... standards 2 Install all protective shields and panels that were removed for wiring installation 3 Provide power to the backplane 5 TURNUP When an NIU3 is inserted into a shelf with power on the backplane the STATUS LED turns on red while the NIU3 performs a self test If the test passes the STATUS LED turns on green and the other LEDs go through an on off sequence indicating the NIU3 is online If ...

Page 5: ...cent to the alarm wire wrap pins on the backplane The alarm relay output responds to the card malfunction status on individual NIU3 cards If an alarm condition occurs but an alarm signal is not present then a failed alarm relay is indicated Follow this procedure to replace a failed alarm relay 1 Using an appropriately sized IC extractor tool lift the relay off its socket 2 Align and insert the rep...

Page 6: ...es support CAPS requests or further information ADTRAN Sales Pricing Availability 800 827 0807 ADTRAN Technical Support Pre Sales Applications Post Sales Technical Assistance 800 726 8663 Standard hours Monday Friday 7 a m 7 p m CST Emergency hours 7 days week 24 hours day ADTRAN Repair CAPS Return for Repair Upgrade 256 963 8722 Repair and Return Address Contact Customer and Product Service CAPS ...

Reviews: