TR ISDN

CLEI:DDRPLRC1AA

DEPLOYMENT GUIDELINES

TOTAL REACH SC PAM SIDE

Maximum Loop Loss .......................46 dB @ 20 kHz using a 135 ohm termination

52 dB @ 28 kHz using a 135 ohm termination

Maximum Noise................................34 dBrn using a 135 ohm termination with a 50 kB filter

Maximum DC Resistance.................2000 ohms

Maximum Single Bridged Tap...........2 kft

Maximum Total Bridged Tap..............6 kft

Maximum # of Bridged Taps..............3

Nominal Voltage.................................-130 VDC from TIP (GND) to RING (-130 v)

Note: Bridged Tap length must be included as part of the total loop length.

U-INTERFACE SIDE

Maximum Loop Loss .......................42 dB @ 40 kHz using a 135 ohm termination

Maximum Noise................................33 dBrn using a 135 ohm termination with a 50 kB filter

Maximum DC Resistance.................1300 ohms

Maximum Single Bridged Tap...........3 kft

Maximum Total Bridged Tap..............6 kft

Maximum # of Bridged Taps..............3

Voltage.................................-48 VDC from TIP (GND) to RING (-48 v)

T400 EDGE CONNECTOR PIN ASSIGNMENTS

55

TIP, U-Interface

49

RING, U-Interface

47

RING, Total Reach Interface

41

TIP, Total Reach Interface

27

Frame GND

11

Frame GND

Note: ISDN connections are not polarity sensitive 

STATUS LEDs

NT1 I/F

ON

Indicates a loss of signal from or synchronization 

with the 2B1Q BRI interface towards customer’s 

NT1.

FLASHING Once per second indicates receipt of a Near End

Block Error from the 2B1Q BRI interface.

TRI I/F

ON

Indicates a loss of signal or synchronization with 

the TRI-C (Total Reach ISDN CO) unit

FLASHING Once per second indicates receipt of a Near End

Block Error from the TRI-C unit

LOOPBACK

ON

Indicates the TRI-R unit is in a 2B+D loopback 

FLASHING Oncer per second for B1 loopback, twice per second

for B2 loopback

ACT

ON

Indicates the terminal equipment has exchanged 

ACT bits with the ISDN switch

FLASHING Once per second indicates that the ACT bit is being

sent from only the terminal equipment (CPE)

OPTIONS

S1-1 SX
ON

Default and normal condition. Provides between 4 to 10 mA of sealing
current toward the customer’s NT1/TA.

OFF

Disables sealing current to the customer’s NT1/TA.

S1-2 TEST
ON

Used for factory test only.

OFF

Default and operational mode.