background image

6

Section 61150279L1-5, Issue 1

61150279L1-5A

5. To deactivate the loopback press the TEST

pushbutton. Upon deactivation of the test the
DS0 LED will go Off.

Local Performance Monitoring

Performance monitoring of the local E1 carrier system
and the 2-wire U-interface of the ISDN data can be
performed from the front panel without interruption of
service to the customer. For this test, bearer channel
selection is not applicable and a test pattern source is
not required. To initiate local performance
monitoring, conduct the following:

1. Ensure a bantam plug is NOT inserted in the TX

jack on the E1 LIU.

2. Select the desired U-BR1TE channel unit using

the DSL switch on the LIU.

3. Select ADR1 on the LIU Address switch.

4. Press the TEST pushbutton to initiate the test.

The DS0-LB LED will turn ON.

5. The total number of CRC errors is

simultaneously displayed by the LP CRC and CR
CRC LEDs. The LEDs will Flash for more than 6
but less than 19 errors, and

 

turn ON steady for

more than 20 errors.

4.  SPECIFICATIONS

The specifications for the BR1/10 E1 LIU are listed in

Table␣ 3.

5.  MAINTENANCE

The BR1/10 E1 LIU does not require routine
maintenance for normal operation.

ADTRAN does not recommend that repairs be
performed in the field. Repair services are obtained by
returning the defective unit to ADTRAN Customer
Service. See 

Warranty and Customer Service

.

6. WARRANTY AND CUSTOMER SERVICE

ADTRAN will replace or repair this product within 10
years from the date of shipment if it does not meet its
published specifications or fails while in service (see

ADTRAN Carrier Network Equipment Warranty,
Repair, and Return Policy and Procedure, 

document

60000087-10A).

Contact Customer and Product Service (CAPS) prior
to returning equipment to ADTRAN.

For service, CAPS requests, or further information,
contact one of the following numbers:

ADTRAN  Sales

Pricing and availability
(800) 827-0807

ADTRAN Technical Support

Presales Applications / Post-sale Technical Assistance
(800) 726-8663

Standard support hours:
Monday-Friday, 7 a.m. - 7 p.m. CST

Emergency support:  7 days/week, 24 hours/day

ADTRAN Repair/CAPS

Return for repair / upgrade
(256) 963-8722

Repair and Return Address:

ADTRAN, Inc.
CAPS
901 Explorer Boulevard
Huntsville, Alabama  35806-2807

Table 3.  BR1/10 E1 LIU Specifications

l

a

t

n

e

m

n

o

r

i

v

n

E

e

r

u

t

a

r

e

p

m

e

T

g

n

i

t

a

r

e

p

O

C

°

0

7

+

o

t

C

°

0

4

-

)

F

°

8

5

1

+

o

t

F

°

0

4

-

(

e

r

u

t

a

r

e

p

m

e

T

e

g

a

r

o

t

S

C

°

5

8

+

o

t

C

°

0

4

-

)

F

°

5

8

1

+

o

t

F

°

0

4

-

(

y

t

i

d

i

m

u

H

e

v

i

t

a

l

e

R

g

n

i

s

n

e

d

n

o

c

n

o

n

%

5

9

l

a

c

i

s

y

h

P

s

n

o

i

s

n

e

m

i

D

t

h

g

i

e

W

W

"

8

/

7

x

H

"

2

/

1

2

x

L

"

8

/

3

9

z

O

2

.

3

Reviews: