background image

61287800F1-13A

3

3.  Attach one end of the cable to the 

SFP+

WAN

 

or 

XFP WAN

 port on 

the front of the ADTRAN 602.

Step 5: Connect Power

To connect power to the ADTRAN 602, complete the following steps:

1. Plug the supplied 12V AC/DC Power Converter into the 

POWER

 

connection on the front of the ADTRAN 602.

2. Connect the Power Converter to a standard 100-240V AC outlet. 

3. Verify the power is on by checking the 

POWER

 LED on the 

ADTRAN 602. The LED should be green indicating local power is 
on.

Step 6: Connect UPS (Optional)

The 

UPS

 must be UL Listed, and have a 

LPS

 with an output rated at 12

VDC minimum 3.0 Amps and suitable for the intended location.
The UPS connection on the front of the ADTRAN 602 is used to connect a 
commercial UPS Battery backup unit. To connect the USP backup power 
supply, complete the following steps:

1. Connect the power cord from the UPS Battery backup unit to the 

UPS

 connection on the front of ADTRAN 602.

2. Connect the UPS Battery backup unit to a regular 100-240 VAC 

outlet.

F

RONT 

P

ANEL 

LED

S

When the ADTRAN 602 first powers up it performs self-tests. Once the 
power up self-tests are complete, the status 

LEDs

 will reflect the true 

state of the hardware.

Resetting the ONT

w

     NOTICE

Resetting the ONT returns all settings to their factory defaults. Regis-
tration provisioning will be lost.

A reset button is available if the ADTRAN 602 needs to be rebooted. To 

reset the ADTRAN 602, press the RESET button for 5 seconds or longer. 

A

CRONYMS

AWG

 

American Wire Gauge

GE 

Gigabit Ethernet

LAN

 Local 

Area 

Network

LED 

Light Emitting Diode

LPS

Local Power Supply

Label

Status

Indication

POWER

Off
ON

Power is off
Power is on

WAN

2

Off
Yellow
Yellow Flashing 
Green
Red

No light detected from OLT
ONT detects light from OLT
Ranging in process
ONT is ranged and up
ONT discovered, but not active

LAN

2

2

Off
Green
Green Flashing
Yellow
Yellow Flashing 
Red

LAN is down
10G link is up
Data transfer in process
Data rate is out of range
Data transfer in process
Port is Administratively up, Link is 
down

NG-PON 

Next Generation Passive Optical Network

ODC 

Optical Directional Coupler

OMCI 

OpenManage

TM 

Client Instrumentation

ONT 

Optical Network Terminal

PON 

Passive Optical Network

SC/UPC 

Standard Connector/Ultra Physical Contact

SFP

Small Form-factor Pluggable

UPS

 

Uninterruptible Power Supply 

TWDM 

Time and Wavelength Division Multiplexing

 

WAN 

Wide Area Network

XFP 

10G Form-factor Pluggable

XGSPON 

Ten Gigabits Passive Optical Network

Operational Specifications

Electrical

Operating Voltage: 12 VDC

AC to DC Power Supply: 100 to 240 VAC, 50 to 60 Hz

Power Consumption: Typical 25 watts

Physical

8.0 inches wide (20.0 centimeters)

8.0 inches deep (20.0 centimeters)

 1.75 inches high (4.5 centimeters)

Weight: 2 pounds (0.9 kilograms)

Environmental

Operational Temperature: –5°C to +50°C (+23°F to 122°F)

Storage Temperature: –2°C to +85°C (+28°F to 185°F)

Relative Humidity: 90%, noncondensing

M

AINTENANCE

The ADTRAN 602 does not require routine hardware maintenance for 
normal operation. ADTRAN does not recommend that repairs be 
attempted in the field. Repair services may be obtained by returning the 
defective unit to ADTRAN. Refer to the warranty for further information. 
Field support for software is provided through upgrade facilities.

S

AFETY AND 

R

EGULATORY

f

     

WARNING!

Read all warnings and cautions before installing or servicing this 
equipment.

Refer to the national, state and local electrical codes for the 
requirements for power and grounding wiring methods.

The Gigabit Ethernet port(s) are classified as Type 4a, as defined in 
Appendix B of GR-1089-CORE, and is/are suitable for connection to 
intra-building, unexposed, wiring or cabling only. Do not metallically 
connect the Gigabit Ethernet port(s) to interfaces which connect to 
exposed or Outside Plant (OSP) wiring or cabling. The Gigabit 
Ethernet port(s) is/are designed for use as intra-building interface(s) 
only (4a ports as described in GR-1089-CORE) and requires isolation 
from exposed OSP cabling. The addition of Primary Protectors is not 
sufficient protection in order to connect the interface metallically to 
OSP wiring.

C

     

CAUTION!

     

This product contains or uses a Class 1 Laser module that complies 
with FDA 21 CFR 1040.10, 1040.11 and IEC 60825-1. For continued 
compliance with the above standards, only approved Class 1 laser 
modules from an ADTRAN approved vendor list (located on the 

Summary of Contents for 602

Page 1: ...cluding the following UL CUL 60950 1 IEC 60950 1 EN 60950 1 AS NZS 60950 1 RoHS FCC Part 15 Class B IEEE 802 3 FRONT PANEL CONNECTIONS The following table describes the connections on the front panel INSTALLATION Before installing the ADTRAN 602 inspect it for damage If damage has occurred during shipping file a claim with the carrier and then contact ADTRAN For more information refer to the warra...

Page 2: ...g the SFP XFP The latch on the SFP XFP is for removal only When removing the SFP XFP rotate the latch away from the SFP XFP cage until a physical click occurs The SFP XFP should slide easily out of the cage Always have dust caps and dust plugs installed when connectors or adapters are not mated Store dust caps in a sealable plastic bag when not in use Step 4 Install SFP or XFP To install the SFP o...

Page 3: ...al Directional Coupler OMCI OpenManageTM Client Instrumentation ONT Optical Network Terminal PON Passive Optical Network SC UPC Standard Connector Ultra Physical Contact SFP Small Form factor Pluggable UPS Uninterruptible Power Supply TWDM Time and Wavelength Division Multiplexing WAN Wide Area Network XFP 10G Form factor Pluggable XGSPON Ten Gigabits Passive Optical Network Operational Specificat...

Page 4: ...alisation de toute opération de maintenance Consultez les normes nationales régionales et locales sur les installations électriques pour connaître les exigences en matière de câblage pour l alimentation et la mise à la terre C ATTENTION Ce produit contient ou utilise un module laser de classe 1 qui est conforme à la FDA 21 CFR 1040 10 1040 11 et IEC 60825 1 Pour maintenir la conformité avec les no...

Reviews: