ADTRAN 324RG Manual Download Page 4

T

ROUBLESHOOTING

The following table can be used for troubleshooting purposes:

S

PECIFICATIONS

Refer to the following for a list of all specifications for the Indoor 
Home Gateway ONT.

Electrical

o

Voltage: 12 Volts typical

o

Minimum Voltage: 10 Volts

o

Maximum Voltage: 13.9 Volts

o

Power Consumption: Typical 13.9 watts

Physical

o

10.0 inches wide (19.5 centimeters)

o

5.9 inches deep ((18.8 centimeters)

o

 1.5 inches high (3.3 centimeters no bracket, 5.1 with bracket)

o

Weight: 2 pounds (0.9 kilograms)

Environmental

o

Operational Temperature: 32°F to +113°F (0°C to +50°C)

o

Storage Temperature: –40°F to 185°F (–20°C to +50°C)

o

Relative Humidity: 90%, noncondensing

Problem

Possible Solution

The Power LED is Off

Verify that the power adapter is 
plugged into a live AC outlet.

Check that he 

ON/OFF 

button 

is pressed in.

Check the power cable for shorts 
or breaks.

Disconnect the power input con-
nector at the ONT and use a volt-
meter to verify that the proper 
voltage level is present on the 12 
V pin (power and power return) 
from the power adapter.

The LINK LED is Off

Check that the optical fiber is 
connected correctly.
Check the optical connector for 
dirt or damage.

LINK LED is ON, but 
INTERNET LED is Off

The signal sent by the service 
provider is not being received. 
Contact the service provider for 
assistance.

The LAN LED is Off

Check that the Ethernet cable is 
connected correctly.
Check that the network adaptor 
works normally. Refer to the doc-
umentation that accompanied 
the network adapter as needed.

Optical

o

TX min power: 0.5 dBm

o

TX max power: 5.0 dBm

o

RSSI max sensitivity: -27 dBm

o

RX overload: -8 dBm

o

TX wavelength: 1310 nm typical

o

RX wavelength: 1490 nm typical

M

AINTENANCE

The Indoor 2 POTS + 4GigE does not require routine hardware 
maintenance for normal operation. ADTRAN does not 
recommend that repairs be attempted in the field. Repair services 
may be obtained by returning the defective unit to ADTRAN. 
Refer to the warranty for further information. Field support for 
software is provided through upgrade facilities.

S

AFETY

 

AND

 R

EGULATORY

 C

OMPLIANCE

Refer to the Total Access 324RG

 

Indoor 2 POTS + 4GigE

 Safety and 

Regulatory Compliance Notice

 (61287562G1-17) for detailed safety 

and regulatory information.

DRAFT

61287562G1-22A

4