The second terminal emulation mode is Manual
Update Mode which allows the user to manually
update the provisioning option screens. This mode
supports efficient print screen and log file utilities for
storage of key provisioning parameters, alarm or
performance history and current system status. “3
SPACES TO UPDATE” appears at the top of each
screen. By pressing the space bar 3 times, the screen
will be refreshed and will reflect the most current
circuit conditions and provisioning options.
The Alarm History Screen, illustrated in
Figure 20
,
provides the user with a detailed alarm history and
events log for the HDSL2 and T1 spans.
This screen includes a time, date, first/last occurrence,
and count for each type of HDSL2 or T1 alarm.
Figure 20. Alarm History Screen
CIRCUIT ID: 01/01/00 00:41:34
T1 Alarm History
LOCATION ALARM FIRST LAST CURRENT COUNT
--------------------------------------------------------------------------------
H2TU-C RED(LOS/LOF) 01/01/00 00:00:04 01/01/00 00:00:04 Alarm 001
(DSX-1) YELLOW(RAI) OK 000
BLUE(AIS) OK 000
H2TU-R RED(LOS/LOF) OK 000
(DS1) YELLOW(RAI) OK 000
BLUE(AIS) 01/01/00 00:00:31 01/01/00 00:00:31 Alarm 001
--------------------------------------------------------------------------------
1. T1 Alarm 2. HDSL2 Span C. Clear T1 Alarm
Selection: