C A U T I O N
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Warranty:
ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at
©2010 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442704PG1-22A*
CAUTION
!
♦
Per
GR
‐
1089
‐
CORE
the
ADTRAN
system
that
the
SFP
is
being
deployed
in
is
designed
and
intended
for
installation
as
part
of
a
Common
Bonding
Network
(CBN).
The
ADTRAN
system
that
the
SFP
is
being
deployed
in
is
not
designed
nor
intended
for
installation
as
part
of
an
Isolated
Bonding
Network
(IBN).
♦
Per
GR
‐
1089
‐
CORE
Section
9,
the
Bidirectional
SFP
does
not
have
an
internal
DC
connection
between
battery
return
and
frame
ground.
The
Bidirectional
SFP
can
be
installed
in
a
DC
‐
I
(isolated)
or
DC
‐
C
(common)
installation.
For
installations
where
other
cards
or
the
host
system
have
internal
connections
between
battery
return
and
frame
ground,
the
system
would
be
intended
for
deployment
only
in
a
DC
‐
C
installation.
♦
The
ADTRAN
system
chassis
frame
ground
terminal
must
be
connected
to
a
reliable
earth
ground
to
ensure
that
the
metal
enclosure
of
the
Bidirectional
SFP
is
properly
grounded
via
the
backplane
connector.
CAUTION
C
The
Small
Form
‐
Factor
Pluggable
OC
‐
12
Bidirectional
1310/1550
nm
is
a
Class
1
Laser
Product
and
complies
with
the
Laser
Safety
requirements
of
FDA
21
CFR
1040.11,
EN60825
‐
1,
and
EN60825
‐
2.
The
Bidirectional
SFP
is
NRTL
Listed
and
CB
Certified
to
all
applicable
American
and
European
safety
standards.
NOTE
The
Gigabit
Ethernet
port(s)
are
optical
and
therefore
are
not
classified
as
any
type
of
port
as
defined
in
Appendix
B
of
GR
‐
1089
‐
CORE
Issue
5.
The
Bidirectional
SFP
is
designed
to
meet
the
following
environ
‐
mental
classes:
♦
ETSI
EN
300
019
‐
1
‐
1
“Classification
of
environmental
conditions;
Storage,”
Class
1.2
♦
ETSI
EN
300
019
‐
1
‐
2
“Classification
of
environmental
conditions;
Transportation,”
Class
2.3
♦
ETSI
EN
300
019
‐
1
‐
3
“Classification
of
environmental
conditions;
Stationary
use
at
weather
‐
protected
locations,”
Class
3.3
The
equipment
is
designed
to
function
without
degradation
during
exposure
to
all
test
severities
per
Class
3.3.
www.adtran.com
for
further
information
on
RoHS/WEEE.
NOTE
♦
This
Bidirectional
SFP
is
compliant
with
SFF
‐
8472
“Digital
Diagnostics
Monitoring
Interface
for
Optical
Transceivers,”
Revision
9.3.
♦
This
Bidirectional
SFP
is
compliant
with
the
Small
Form
‐
Factor
Pluggable
(SFP)
Multi
‐
Source
Agreement
(MSA).
♦
This
Bidirectional
SFP
is
designed
to
be
deployed
in
GR
‐
3108
‐
CORE
environmental
class
1
or
2
as
defined
in
GR
‐
3108
‐
CORE
Issue
2.