C A U T I O N
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
CAUTION
!
The
SFP
is
intended
for
deployment
in
Central
office
type
facilities,
EEEs,
EECs,
and
locations
where
NEC
applies
(for
example,
Customer
Premises).
The
SFP
must
be
installed
by
trained
service
personnel
in
ADTRAN
products
that
are
located
in
Restricted
Access
Locations.
This
device
complies
with
Part
15
of
the
FCC
rules.
Operation
is
subject
to
the
following
two
conditions:
1. This
device
may
not
cause
harmful
interference.
2. This
device
must
accept
any
interference
received,
including
interference
that
may
cause
undesired
operation.
Changes
or
modifications
not
expressly
approved
by
ADTRAN
could
void
the
user
ʹ
s
authority
to
operate
this
equipment.
CAUTION
!
♦
Per
GR
‐
1089
‐
CORE
the
ADTRAN
system
that
the
SFP
is
being
deployed
in
is
designed
and
intended
for
installation
as
part
of
a
Common
Bonding
Network
(CBN).
The
ADTRAN
system
that
the
SFP
is
being
deployed
in
is
not
designed
nor
intended
for
installation
as
part
of
an
Isolated
Bonding
Network
(IBN).
♦
Per
GR
‐
1089
‐
CORE
Section
9,
the
SFP
does
not
have
an
internal
DC
connection
between
battery
return
and
frame
ground.
The
SFP
can
be
installed
in
a
DC
‐
I
(isolated)
or
DC
‐
C
(common)
configuration.
For
installations
where
other
cards
or
the
host
system
have
internal
connections
between
battery
return
and
frame
ground,
the
system
would
be
intended
for
deployment
only
in
a
DC
‐
C
configuration.
♦
The
ADTRAN
system
chassis
frame
ground
terminal
must
be
connected
to
a
reliable
earth
ground
to
ensure
that
the
metal
enclosure
of
the
SFP
is
properly
grounded
via
the
backplane
connector.
NOTE
♦
The
GPON
is
optical
and
therefore
is
not
classified
as
any
type
of
port
as
defined
in
Appendix
B
of
GR
‐
1089
‐
CORE
Issue
5.
♦
The
SFP
is
designed
for
deployment
in
GR
‐
3108
‐
CORE
environmental
class
1
and
2,
as
defined
in
GR
‐
3108,
Issue
2.
The
SFP
is
designed
to
meet
the
following
environmental
classes:
♦
ETSI
EN
300
019
‐
1
‐
1
“Classification
of
environmental
conditions;
Storage,”
Class
1.2
♦
ETSI
EN
300
019
‐
1
‐
2
“Classification
of
environmental
conditions;
Transportation,”
Class
2.3
♦
ETSI
EN
300
019
‐
1
‐
3
“Classification
of
environmental
conditions;
Stationary
use
at
weather
‐
protected
locations,”
Class
3.3
The
equipment
is
designed
to
function
without
degradation
during
exposure
to
all
test
severities
per
Class
3.3.
Warranty
:
ADTRAN will replace or repair this product within the warranty period if it does not meet its
published specifications or fails while in service. Warranty information can be found online at
www.adtran.com/warranty
.
©2010 ADTRAN, Inc. All Rights Reserved.
*61442530G1-22A*
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
NOTE
♦
This
SFP
is
compliant
with
SFF
‐
8472
“Digital
Diagnostics
Monitoring
Interface
for
Optical
Transceiver,”
Revision
9.3
♦
This
SFP
is
compliant
with
Small
Form
‐
Factor
Pluggable
(SFP)
Multi
‐
Source
Agreement
(MSA).
♦
The
SFP
complies
with
G984.2
Class
B+
optics
requirements
with
the
following
exceptions:
1.
Enhanced
Receiver
Sensitivity
of
–30
dBm
2.
Minimum
Receiver
Overload
of
–10
dBm