2
61442470FX-22A
S
AFETY
AND
R
EGULATORY
C
OMPLIANCE
WARNING
!
Read all warnings and cautions before installing or servicing this
equipment.
CAUTION
C
This product uses a Class 1 Laser module that complies with 21
CFR 1040.10 and 1040.11 and IEC 60825-1 and -2. For continued
compliance with the above standards, only approved Class 1 laser
modules from an ADTRAN approved vendor list (located on the
ADTRAN website) should be installed in this product. ADTRAN
cannot certify system integrity with other laser modules.
CAUTION
!
■
Electrostatic Discharge (ESD) can damage electronic modules.
When handling modules, wear an antistatic discharge wrist
strap to prevent damage to electronic components. Place
modules in antistatic packing material when transporting or
storing. When working on modules, always place them on an
approved antistatic mat that is electrically grounded.
■
Per GR-1089-CORE, this system is designed and intended for
installation as part of either a Common Bonding Network
(CBN) or Isolated Bonding Network (IBN).
■
Per GR-1089-CORE Section 9, this product does not have an
internal DC connection between battery return and frame
ground. This product can be installed in a DC-I (isolated) or
DC-C (common) configuration. For installations where other
cards or the host system have internal connections between
battery return and frame ground, the system would be
intended for deployment only in a DC-C configuration.
■
The chassis frame ground terminal must be connected to an
earth ground to ensure that the metal enclosure of the SFP is
properly grounded via the backplane connector.
NOTE
■
The SFP port is optical and therefore are not classified as any
type of port as defined in Appendix B of GR-1089-CORE.
■
This product is designed to be deployed in GR-3108-CORE
environmental class 1, 2, and 3 as defined in GR-3108-CORE.
The SFP+ is NRTL Listed to the applicable UL standards. The
SFP+ meets or exceeds all the applicable requirements of NEBS,
Telcordia GR-63-CORE, and GR-1089-CORE. The SFP+ is
intended for deployment in Central Office type facilities, EEEs,
EECs, and locations where the NEC applies (for example,
Customer Premises). Install the SFP+ in an ADTRAN product
located in a restricted access location.
Configuration Code
Input
Output
Power Code (PC)
F
C
Telecommunication Code (TC)
–
–
Installation Code (IC)
A
–
I
NSTALLATION
Before installing the equipment, inspect the SFP+. If damage has
occured during shipping, file a claim with the carrier, and then
contact ADTRAN Customer Support. For more information, refer
to “Warranty”.
To install the SFP+ into an appropriate module, complete the
following steps:
1. Insert the SFP+ into the SFP cage on the circuit board of the
host module with the latch handle facing outward. Slide the
SFP+ all the way into the cage until there is an audible click.
2. Do not remove the connector plug until the optical fiber
connection is ready to be made.
NOTE
The latch on the SFP+ is for removal only.
3. Continue the installation and turn-up of the host module
using the instructions in the Job Aid provided with that
module, or using the documentation, available online at
www.adtran.com.
NOTICE
When removing an SFP+, remove the fibers first.
M
AINTENANCE
The
SFP+
does
not
require
routine
hardware
maintenance
for
normal
operation.
ADTRAN
does
not
recommend
that
repairs
be
attempted
in
the
field.
Repair
services
may
be
obtained
by
returning
the
defective
unit
to
ADTRAN.
Refer
to
the
warranty
for
further
information.