Warranty:

ADTRAN will replace or repair this product within the warranty period if it does not meet 

its published specifications or fails while in service. Warranty information can be found 

online at 

www.adtran.com/warranty

.

Trademarks:

 Brand names and product names included in this document are trademarks, 

registered trademarks, or trade names of their respective holders.

©2018 ADTRAN, Inc. All Rights Reserved.

ADTRAN CUSTOMER CARE:

From within the U.S.

1.800.726.8663

From outside the U.S.

1.256.963.8716

PRICING AND AVAILABILITY 1.800.827.0807

*61442200G1-22B*

S

AFETY

 

AND

 R

EGULATORY

WARNING

!

The Ethernet port is classified as Type 2 or Type 4, as defined in 
GR-1089-CORE, Issue 5, Appendix B, and is suitable for 
connection to intrabuilding or unexposed wiring or cabling 
only. Do not metallically connect this port to any interface 
which connects to the Outside Plant (OSP) or to the OSP wiring. 
The addition of Primary Protectors is not sufficient protection 
in order to connect this interface metallically to OSP wiring.

The Ethernet port is suitable for connection only to shielded 
intra-building cabling, grounded at both ends.

!

   

CAUTION

Electrostatic Discharge (ESD) can damage electronic modules. 
When handling electronic components, wear an antistatic 
discharge wrist strap to prevent damage. Place modules in 
antistatic packing material when transporting or storing. When 
working on modules, always place them on an approved 
antistatic mat that is electrically grounded.

This product is NRTL listed to all applicable UL standards. This 
product meets or exceeds all applicable requirements of NEBS, 
Telcordia GR-63-CORE, GR-78-CORE, and GR-1089-CORE. 
This product is intended for deployment in Central Office type 
facilities, EEEs, EECs, and locations where the NEC applies 
(e.g., Customer Premises).

This product should be installed by qualified Service Personnel 
only, in an ADTRAN module intended for installation in an 
ADTRAN host system located in a restricted access location.

Per GR-1089-CORE this product is designed and intended for 
installation as part of a Common Bonding Network (CBN). This 
product is not designed nor intended for installation as part of 
an Isolated Bonding Network (IBN).

Per GR-1089-CORE, Section 9, this product does not have an 
internal DC connection between –48 VR and frame ground. 
This product can be deployed in an Isolated (DC-I) or Common 
(DC-C) configuration. For installations where other modules or 
the host system have internal connections between –48 VR and 
frame ground, the system would be intended for deployment 
only in a DC-C configuration.

The host chassis frame ground terminal must be connected to 
an earth ground to ensure that the metal enclosure of this 
product is properly grounded via the backplane connector.

NOTE

This product is designed for deployment in GR-3108-CORE 
environmental class 1 and 2, as defined in GR-3108-CORE, 
Issue 2.

This product is designed to meet the following environmental 
classes:

ETSI EN 300 019-1-1 “Classification of environmental condi-
tions; Storage,” Class 1.2

ETSI EN 300 019-1-2 “Classification of environmental condi-
tions; Transportation,” Class 2.3

ETSI EN 300 019-1-3 “Classification of environmental condi-
tions; Stationary use at weather-protected locations,” Class 
3.3

The equipment is designed to function without degradation 
during exposure to all test severities per Class 019-1-3 3.3.

This product complies with ETSI EN 300 386 “Electromagnetic 
compatibility and Radio spectrum Matters (ERM);
Telecommunication network equipment;
Electromagnetic Compatibility (EMC) requirements.”

This device complies with Part 15 of the FCC rules. Operation 
is subject to the following two conditions:

1.

This device may not cause harmful interference. 

2.

This device must accept any interference received, including 
interference that may cause undesired operation.

Changes or modifications not expressly approved by ADTRAN 
could void the user’s authority to operate this equipment.

This product meets the EU RoHS Directive 2002/95/EC and/or
applicable exemptions. For more information on RoHS/WEEE, 
refer to 

www.adtran.com

.

C A U T I O N 

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.