Troubleshooting
61287722G1-5B
35
Troubleshooting
When
troubleshooting
a
SBU
ONT
unit,
consider
the
following
two
principles:
• Because
voice
and
data
signals
originate
at
the
OLT
equipment,
a
failure
of
all
services
normally
indicates
the
problem
is
before
the
SBU
ONT.
A
failure
at
the
OLT
equipment
normally
results
in
a
loss
of
service
to
multiple
customers.
• The
OLT
has
diagnostic
testing
procedures
that
can
monitor
the
status
of
every
SBU
ONT
in
the
system,
which
very
often
can
direct
you
to
the
root
cause
of
the
trouble.
NOTE
The
home
telephone
wires
are
connected
using
pivot
connectors,
and
the
RJ
‐
11
jack
serves
as
a
test
access
point.
In
this
configuration,
inserting
a
telephone
cable
into
the
RJ
‐
11
jack
will
disconnect
the
SBU
ONT
from
home
wiring
and
connect
the
SBU
ONT
to
the
inserted
cable
instead.
This
allows
the
home
owner
or
service
provider
to
diagnose
SBU
ONT
or
home
wiring
related
problems.
Inserting
an
RJ
‐
11
jack
(such
as
a
telephone
cable
or
telephone
test
set)
into
the
connector,
will
connect
the
telephone
set
and
also
disconnect
the
subscriber
service
from
the
SBU
ONT.
Hence
fault
may
be
isolated
to
the
SBU
ONT
or
premises
wiring.
This
section
describes
how
to
troubleshoot
and
correct
the
following:
•
•
•
•
Faults Indicated with LEDs
Begin
troubleshooting
at
the
SBU
ONT
by
checking
to
see
if
all
LEDs
are
in
their
normal
state,
shown
in
There
are
separate
LEDs
for
each
Ethernet
RJ
‐
45
jack
that
appear
on
the
SBU
circuit
board.
If
the
LEDs
are
in
their
normal
state,
refer
to
below.
If
the
LEDs
are
in
a
fault
state,
refer
to
LEDs in Normal State
If
the
LEDs
are
in
the
normal
state
but
you
are
still
having
problems,
complete
the
following
troubleshooting
steps:
1. If
the
trouble
is
of
a
random
or
intermittent
nature,
check
for
loose
or
broken
connections
at
the
common
mounting
platform.
2. If
the
trouble
is
solid,
remove
the
Customer
Provided
Equipment
(CPE)
wiring
and
perform
the
following
tests:
• POTS
tests
described
in
• Ethernet
tests
described
in
Verify
the
OLT
can
run
and
pass
the
loop
‐
back
tests
for
the
Ethernet
port.
If
the
above
tests
are
successful,
the
indication
of
the
trouble
is
directed
back
toward
the
CPE
wiring/equipment.