C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY
HANDLING PRECAUTIONS REQUIRED
Warranty
: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can be
found online at
www.adtran.com/warranty
.
Trademarks:
Brand names and product names included in this document are trademarks,
registered trademarks, or trade names of their respective holders.
©2015 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61287405F1-22B*
When the ONT first powers up, it performs self-tests. Once the power
up self-tests are complete, the status LEDs will reflect the true state of
the hardware.
ONT LED S
TATUS
The ONT LEDs are located beneath the plastic housing and are only
visible after power has been applied. The following table provides the
LED status during normal operations.
Step 7: Attach UPS Wall Mount Cover
To install the Wall Mount Housing Cover, refer to
and
complete the following steps:
1. Align the hole in the Wall Mount Housing Cover with the hole
in the Wall Mount Housing and snap the Cover in place.
2. Secure the Cover to the Wall Mount Housing using the screw
provided.
Figure 10. Attach UPS Wall Mount Cover
Label
Status
Indication
POWER
Off
Green
ONT power is Off
ONT power On
FIBER
2
Off
Green
Green Flashing Fast
ONT is not active (not Ranged)
ONT is active (Ranged)
ONT is activating (Ranging in
progress)
LAN
2
Off
Green
Green Flashing Fast
LAN Port not connected
LAN Port connected, but data is
not being transmitted
LAN Port connected, and data is
being transmitted
VOICE
2
Off
Green
Green Flashing Slow
Unequipped or on-hook and not
ringing
Off-hook
On-hook with line in ringing
state
M
AINTENANCE
The Wall Mount Housing does not require routine hardware mainte-
nance for normal operation. ADTRAN does not recommend that
repairs be attempted in the field. Repair services may be obtained by
returning the defective unit to ADTRAN. Refer to the warranty for
further information.
S
PECIFICATIONS
Electrical specifications for the UPS are as follows:
■
Input Voltage Range: 100VAC - 240VAC
■
Input Frequency Range: 50/60 Hz
■
Output Voltage: 12VDC (Nominal) rating
■
Continuous Output Power Capacity: 1.5A (18 Watts)
■
Recharge Time: less than 10 hours
Physical dimensions for Wall Mount Housing are as follows:
■
Height: 9.75 inches (24.8 centimeters)
■
Width: 10.0 inches (25.5 centimeters)
■
Depth: 2.6 inches (6.6 centimeters)
■
Weight: 2.5 pounds (1.1 kilograms, UPS and ONT)
■
Environmental
♦
Operational Temperature Range: –40°C to +30°C
♦
Storage Temperature Range: –40°C to +85°C
♦
Relative Humidity: up to 95%, noncondensing
S
AFETY
AND
R
EGULATORY
C
OMPLIANCE
CAUTION
!
To ensure proper operation of this system, do not block any of the
vents in the housing, or locate the housing in an environment that
would exceed the conditions specified above.