HDSL T200 HTU-R, Span Powered, 60 mA Installation and Maintenance Practice
A-4
61247026L1-5A
Activation (HTU-C)
Source: Customer
1111110
(6 in 7)
Signal sent in-band. HTU-C loops back the T1 data
to the customer equipment.
Activation (HTU-C)
Source: Customer
0011 1111 0001 1110/
3F1E
Signal sent in-band. HTU-C loops back the T1 data
to the customer equipment.
Activation (HTU-R)
Source: Network
1111 1111 0000 0010/
FF02
Signal sent in-band. HTU-R loops back the T1 data
to the network equipment.
Activation (HTU-R)
Source: Network
1110000
(3 in 7)
Signal sent in-band. HTU-R loops back the T1 data
to the network equipment.
Activation (HTU-R)
Source: Customer
1111100
(5 in 7)
Signal sent in-band. HTU-R loops back the T1 data
to the customer equipment.
Activation (HTU-R)
Source: Customer
0011 1111 0000 0010/
3F02
Signal sent in-band. HTU-R loops back the T1 data
to the customer equipment.
Activation (HTU-R)
Source: Network or
Customer
1100 0111 0100 0011/
C742
Signal sent in-band. HTU-R loops back the T1 data
to the source direction. Sends 20 bit errors every 10
seconds.
Activation (HRE-1)
Source: Network or
Customer
1100 0111 0100 0001/
C741
Signal sent in-band. HRE-1 loops back the T1 data
to the source direction. Sends 10 bit errors every 20
seconds.
Activation (HRE-2)
Source: Network or
Customer
1100 0111 0101 0100/
C754
Signal sent in-band. HRE-2 loops back the T1 data
to the source direction. Sends 200 bit errors every
20 seconds.
Query (All Elements)
Source: Network
1101 0101 1101 0101/
D5D5
Signal sent in-band. Any unit that is in network
loopback injects bit errors into the data looped to
the network equipment. The element closest to the
network that is in loopback injects the errors.
• HTU-C that is in a network loopback injects
231 bit errors every 20 seconds.
• HTU-R that is in a network loopback injects
20 bit errors every 10 seconds.
• HRE-1 that is in a network loopback injects
10 bit errors every 20 seconds.
• HRE-2 that is in a network loopback injects
200 bit errors every 20 seconds.
Disable Loopback
Timeout Source:
Network
1101 0101 1101 0110/
D5D6
Signal sent in-band. Loopback Timeout is disabled
as long as any element is in loopback or armed.
Disable Span Power
Source: Network
0110 0111 0110 0111/
6767
Signal sent in-band. Span power is disabled until
this pattern is removed.
Table A-1. HDSL Loopback Control Codes (Continued)
Function
Code (Binary/Hex)
Response