Menu Descriptions
61247026L1-5A
27
Alarm History Screen
The Alarm History screen, illustrated in
, lists the alarm conditions the HDSL circuit.
The T200 HTU-R, SP/60 mA reviews red, yellow, and blue alarm conditions in the circuit to
automatically predict where a fault is located. Once a fault location is suspected, the corre-
sponding portion of the circuit on the screen is highlighted and a message describing the failure
appears.
Figure 14. Alarm History Screen
Circuit ID:HNTSVLALHDSL MM/DD/YY hh:mm:ss
T1 Alarm History
LOCATION ALARM FIRST LAST CURRENT COUNT
--------------------------------------------------------------------------------
HTU-C RED(LOS) 11/13/11 05:30:03 11/13/11 05:30:03 Alarm 001
(DSX-1) YELLOW OK 000
BLUE(AIS) OK 000
HTU-R RED(LOS) 11/13/11 05:30:20 11/13/11 05:30:20 Alarm 001
(DS1) YELLOW OK 000
BLUE(AIS) OK 000
HDSL Span History
-------------------------------------------------------------------------------
SPAN 1 LP1 HLOS 11/13/11 05:30:01 11/13/11 05:30:01 OK 001
LP2 HLOS 11/13/11 05:30:01 11/13/11 05:30:01 OK 001
HTU-C LP1 MRGN 11/13/11 05:30:01 11/13/11 05:30:01 OK 001
LP2 MRGN 11/13/11 05:30:01 11/13/11 05:30:01 OK 001
HRE-1 LP1 MRGN 11/13/11 05:30:01 11/13/11 05:30:01 OK 001
LP2 MRGN 11/13/11 05:30:01 11/13/11 05:30:01 OK 001
Press: C to clear history : H to scroll span alarms : M for main menu