background image

PRICING AND AVAILABILITY  800.827.0807

TECH SUPPORT  800.726.8663

RETURN FOR REPAIR  256.963.8722

www.adtran.com

61223445L2-22A

Warranty

: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. 

 

Warranty information can be found online at 

www.adtran.com/warranty

.

FEATURES

TScan

The 239 H4R incorporates the TScan

 feature, which allows for remote retrieval of circuit diagnostics 

and performance of advanced fault location. For more information, refer to the Installation and 

Maintenance practice.

Fast Retrain

Fast Retrain is an ADTRAN-proprietary feature that minimizes downtime due to an intermittent 

impairment (bad splice, noise burst, etc.).
When such impairments occur after achieving HDSL synchronization, Fast Retrain is invoked to 

restore service within 5 to 7 seconds. This short retrain time allows for reduced downtime compared to 

the traditional 25 to 30 second retrain duration.

NOTE: For proper functionality, install Fast Retrain capable units on both ends of the circuit. Failure 

of a Fast Retrain attempt initiates the traditional (25-30 second) retrain.

Fault Bridging

The Fault Bridging feature minimizes downtime due to intermittent impairments that appear on the 

cable pair, for example, from a Ground Fault Interrupt (GFI), short, micro-interruption, bad splice, or 

noise burst. This feature allows the DSL transceivers to maintain synchronization during an 

interruption, thus avoiding a 25 to 30-second retrain. Depending on the type of impairment, 

interruptions up to 200 ms can be bridged.

Bad Splice Detection

The Runtime TScan bad splice detection feature is an ADTRAN-proprietary non-intrusive method for 

detection of anomalies (bad splices) in the copper plant. This feature non-intrusively monitors the cable 

pair during runtime for the presence of bad splices that can potentially impact service. 
Poor cable splices are often undetected by normal testing methods. Often, these splices present no 

problem for the data transmission equipment until oxidation with the splice itself causes a rapid 

impedance change, which can cause errors, signal margin fluctuation, and retrain of the DSL 

transceivers. The splice detection feature is accessed from the Troubleshooting Screen through the craft 

access port. 

HOUSINGS AND CAPACITIES

Part Number

Description

CLEI Code

Slots

Stub

H4R Capacity

Recommended Slot 

Assignments

Material

Above 

Ground

Below 

Ground

Above 

Ground

Below 

Ground

1150027L1

239/439 Housing

DDMOABA1MA

4

Air

4

4

All

All

Stainless/Polymer

1150027L2

239/439 Housing

DDMOBBA1MA

4

Gel

4

4

All

All

Stainless/Polymer

1150057L1

Universal Housing

DDMODA01RA

4

Air

4

4

All

All

Stainless Steel

1150057L1

Universal Housing

DDMODA01RA

4

Gel

4

4

All

All

Stainless Steel

1150058L1

Universal Housing

DDMOEE01RA

8

Air

8

8

All

All

Stainless Steel

1150058L2

Universal Housing

DDMOFE01RA

8

Gel

8

8

All

All

Stainless Steel

Manufacturer

Description

Manufacturer’s Part Number

Slots

H4R Capacity

Recommended Slot Assignments

Material

Above 

Ground

Below 

Ground

Above Ground

Below Ground

ADC

®

Radiator II

SPX-HRXC-30-AG-016GT

16

16

16

All

All

Stainless Steel

ADC

Radiator

SPX-HRXC-30-B1

8

8

8

All

All

Stainless Steel

Circa Telecom

®

HDSL-12A

760005

12

12

12

All

All

Stainless Steel

Circa Telecom

HDSL-12B

760006

12

12

12

All

All

Stainless Steel

Arris

®

/Lucent

®

/AT&T

®

Keptel

®

 Inter Link

 809

RF809A3-XXX or RF809B3-XXX

12

8

N/A

1, 3, 4, 6

7, 9, 10, 12

N/A

Polymer

Arris/Lucent/AT&T

Keptel Inter Link 818/819

RF819A1 or RF819A2

RF819B1 or RF819B2

25

12

16 *

Chamber 1:

1, 4, 7, 8, 11, 14

Chamber 2:

15, 17, 19, 20, 23, 25

Chamber 1:

1, 3, 5, 7, 8, 10, 12, 14

Chamber 2:

15, 16, 18, 19, 20, 22, 24, 25

Polymer

Arris

Keptel Inter Link 819 Family

AT819B1U or AT819A1U

12

8

8

2, 3, 5, 6, 8, 9, 11, 12

2, 3, 5, 6, 8, 9, 11, 12

Polymer

Arris/Lucent/AT&T

Keptel Inter Link 820 Family

RF820AX or RF820BX

2 to 8

Full

Full

All

All

Polymer

Charles Industries

G21 Series

6212050002xx

25

12

N/A

1,2,4,6,7,8,9,11,13,15,18,24

N/A

Stainless Steel

Charles Industries

G21 Series

6212040002xx

12

6

N/A

1,3,4,6,8,11

N/A

Stainless Steel

* For 16 slot use, the ambient air temperature measured 1 foot away and parallel to the housing should not exceed 115°F (46.1°C).

HDSL4 239 H4R Repeater