Chapter 7. Test Menu
61202060L2-1
TSU LT User Manual
7-5
functioning properly by verifying that no errors are being
counted.
INSERT 511 ERRORS
When running a 511 pattern test, press the
Enter
key to insert
an error into the 511 pattern.
Run Self-test
This menu selection is used to execute an internal self-test.
This is the same self-test that is performed automatically at
power up. The results of the self-tests are displayed in the
LCD. Upon invoking the command the LCD displays
INITIALIZING
and test failures are displayed in the LCD
window (see Figure 7-4). To initialize a self test, proceed
with the following steps:
Step
Action
1
RAM tests; EPROM checksum
2
On board data path; sending a known test pattern
through an on-board loop
3
Front panel LED verification
4
Phase lock loop verify
If a failure is detected, note the failure number and contact
ADTRAN Technical Support.
Executing self-test disrupts normal data flow and prevents remote
communication until the self-test is completed (approximately five
seconds)
Summary of Contents for 1202060L2-1
Page 1: ...TSU LT User Manual Part Number 1202060L2 1 Document Number 1202060L2 1 February 1999...
Page 16: ...List of Tables xvi TSU LT User Manual 61202060L2 1...
Page 28: ...Chapter 1 Introduction 1 12 TSU LT User Manual 1202060L2 1...
Page 44: ...Chapter 4 Status Menu 4 6 TSU LT User Manual 61202060L2 1...
Page 56: ...Chapter 5 Configuration Menu 5 12 TSU LT User Manual 61202060L2 1...
Page 60: ...Chapter 6 Utility Menu 6 4 TSU LT User Manual 61202060L2 1...
Page 72: ...Chapter 8 Example Operations 8 6 TSU LT User Manual 61202060L2 1...
Page 76: ...Appendix B DTE Data Rate Chart B 2 TSU LT User Manual 61202060L2 1...
Page 86: ......