Chapter 7. Test Menu
61200410L1-1B
ESU LT User Manual
61
QRSS ACT TS0s
The ESU LT has an internal QRSS pattern generator and
detector. The pattern only appears in the TS0s assigned to the
Nx56K/64K port. The QRSS test pattern can be used in
conjunction with network loopbacks to perform end-to-end
tests.
511 Active TS0s
The 511 pattern is generated and checked by the Nx56K/64K
serial interface. It only appears in the TS0s assigned to the
Nx56K/64K port.
When used in conjunction with the payload loopback at the
far end, an end-to-end integrity check can be made on the
DTE ports.
All Zeros
Generates an all zero's pattern in every channel.
All Ones
Generates an all one’s pattern in every channel.
CLR ERRORS
C
LR
E
RRORS
has two functions.
1. To clear out the 511 error total when you press
Enter
.
2. To display a total of the 511 errors. If 511 errors are being
received, the display is updated accordingly. See Figure
7-5.
Figure 7-5. Clear Errors Screen
Summary of Contents for 1200410L1
Page 1: ...ESU LT User Manual Part Number 1200410L1 61200410L1 1B February 2003 ...
Page 12: ...Table of Contents 12 ESU LT User Manual 61200410L1 1B ...
Page 14: ...List of Figures 14 ESU LT User Manual 61200410L1 1B ...
Page 16: ...List of Tables 16 ESU LT User Manual 61200410L1 1B ...
Page 20: ...Chapter 1 Introduction 20 ESU LT User Manual 61200410L1 1B ...
Page 28: ...Chapter 2 Installation 28 ESU LT User Manual 61200410L1 1B ...
Page 34: ...Chapter 3 Operation 34 ESU LT User Manual 61200410L1 1B ...
Page 40: ...Chapter 4 Status Menu 40 ESU LT User Manual 61200410L1 1B ...
Page 64: ...Chapter 7 Test Menu 64 ESU LT User Manual 61200410L1 1B ...
Page 79: ...Index 61200410L1 1B ESU LT User Manual 79 W wiring 69 ...