Section 2, Engineering Guidelines
NetVanta 2000 Series System Manual
16
© 2002 ADTRAN, Inc.
61200361L1-1E
1.
EQUIPMENT DIMENSIONS
NetVanta 2050 and 2100
The NetVanta 2050 and 2100 units are 9.0” W, 6.375” D, and 1.625” H and come equipped for table top
and wallmount use. An optional rackmount shelf is available from ADTRAN.
NetVanta 2300 and 2400
The NetVanta 2300 units are17.25" W, 7.75" D, and 1.26" H and come equipped for rackmount use.
2.
POWER REQUIREMENTS
NetVanta 2050 and 2100
The NetVanta 2000 series has a maximum power consumption of 9W and a maximum current draw of
800mA.
NetVanta 2300 and 2400
The NetVanta 2300 has a maximum power consumption of 11W and a maximum current draw of 0.2A.
3.
REVIEWING THE FRONT PANEL DESIGN
NetVanta 2050
The NetVanta 2100 front panel monitors operation by providing status LEDs for both the LAN and WAN
interfaces, as well as VPN tunnels and traffic. The front panel is shown in
.
Figure 1. NetVanta 2050 Front Panel Layout
PWR
STAT
TD
VPN
RD
TD
RD
TD
RD
NetVanta 2050
WAN
LAN
PWR
STAT
TD
VPN
RD
TD
RD
NetVanta 2050
WAN
LAN