background image

Appendix A.  Dial Plan Interface Configuration

A-2

Octal and Quad FXO Modules User Manual

61200310L1-1

Octal and Quad FXO Modules: Network Termination

To interface directly with the network (PSTN) or to interface to the station 
side of a PBX, configure the 

D

IAL

 P

LAN

 as follows. Select 

N

ETWORK

 T

ERM

, and 

define 

S

LT

 as 

FXO+

. The following 

I

FCE

 C

ONFIG

 options are then available.

P

ORTS

 A

VAILABLE

Read security: 5
Shows port allocation for the endpoint. The characters used to define the 
allocation have the following meanings:

N

UMBER

 

OF

 

P

ORTS

Write security: 2; Read security: 5
Defines the number of ports that could be used to answer calls to the num-
bers defined in the Accept Call list. The ports are contiguous beginning with 
the port number selected and the number of ports.

S

IGNALING

 

M

ETHOD

Defines to the ATLAS 550 the type of signaling to be used across this trunk. 
The signaling selected needs to match the signaling being provided by the 
Network (PSTN). The available options include

 L

OOP

 S

TART

 and 

G

ROUND

 

S

TART

.

L

OOP

 S

TART

Defines to the ATLAS 550 the most common 2W supervision.

G

ROUND

 S

TART

Defines to the ATLAS 550 the 2W supervision used by some PBXs. 

D

IGIT

 

S

UPPRESSION

Write security: 3; Read security: 5
When enabled, no digits will be sent toward the Network/PBX after going 
off-hook on an outgoing call.

D

IRECT

 I

NWARD

 

D

IALING

Write security: 3; Read security: 5
Defines whether the FXO port should accept digits from the network after 
answering an incoming call. Setting this field to 

E

NABLED

 activates the fol-

lowing menus: 

DID D

IGITS

 T

RANSFERRED

DID N

UMBER

 P

REFIX

S

TRIP

 MSD

and 

S

OURCE

 ID

. Setting this field to 

D

ISABLED

 activates the following 

menus: 

T

RUNK

 N

UMBER

 and 

S

OURCE

 ID

.

0-9

Describes available ports, as indicated by the displayed digit. This 
digit is the last digit of the port number.

!

The endpoint uses this port.

s

The switched dial plan uses this port elsewhere.

S

The switched dial plan uses this port elsewhere and a conflict ex-
ists with this endpoint.

n

One or more dedicated (nailed) maps use this port.

N

One or more dedicated (nailed) maps use this port and a conflict 
exists with this endpoint.

-

Indicates that this is the wrong kind of port for this endpoint.

Summary of Contents for 1200310L1

Page 1: ...Octal and Quad FXO Modules User Manual Part Number 1200310L1 Octal Part Number 1200329L1 Quad 61200310L1 1D July 2000...

Page 2: ...901 Explorer Boulevard P O Box 140000 Huntsville AL 35814 4000 256 963 8000 2000ADTRAN Inc All Rights Reserved Printed in U S A...

Page 3: ...right to file a complaint with the FCC 5 The telephone company may make changes in its facilities equipment operations or procedures that could affect the proper operation of this equipment If this ha...

Page 4: ...n which case the user will be required to correct the interference at his own expense Shielded cables must be used with this unit to ensure compliance with Class A FCC limits Canadian Emissions Requir...

Page 5: ...TRAN AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED ADTRAN SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES INCLUDING WITHOUT LIM ITATION ALL WARRANTIES OF MERCHANTABILITY AND FITNESS...

Page 6: ...vi...

Page 7: ...2 1 Shipping Contents 2 1 Installing the Octal and Quad FXO Modules 2 1 Wiring 2 2 Power Up and Initialization 2 2 Failed Self Test 2 3 Operation Alarms 2 3 Chapter 3 Operation 3 1 Overview 3 1 Termi...

Page 8: ...LO 3 6 Test LC T R OK 3 6 Test LC No Battery 3 6 Test LC T R Rolled 3 6 Test Ring GND 3 6 Rx ABCD 3 6 Tx ABCD 3 6 Test 3 7 Test 2W 3 7 Tx ABCD 3 7 1kHz Tone 3 7 Loopback 3 7 Configuration 3 8 Port 3...

Page 9: ...res Figure 1 1 Octal FXO Module 1 2 Figure 2 1 Installing the Octal and Quad FXO Modules 2 1 Figure 3 1 Modules Menu 3 2 Figure 3 2 Menu Tree for Octal and Quad FXO Modules Menu 3 3 Figure 3 3 Octal a...

Page 10: ...List of Figures x Octal and Quad FXO Modules User Manual 61200310L1 1...

Page 11: ...61200310L1 1 Octal and Quad FXO Modules User Manual xi List of Tables Table 2 1 Pinout Connection 2 2 Table 3 1 Test 2W Information 3 7...

Page 12: ...List of Tables xii Octal and Quad FXO Modules User Manual 61200310L1 1...

Page 13: ...rt operation Functional Description The Octal and Quad FXO Modules install in any available option slot in the ATLAS 550 chassis Status information is available via the terminal menus accessible throu...

Page 14: ...tal and Quad FXO Modules plug into any available option slot in the rear of the ATLAS 550 chassis Figure 1 1 shows the Octal FXO Module Figure 1 1 Octal FXO Module The labels over the modular connecto...

Page 15: ...FXO Module Octal and Quad FXO Modules User Manual Insert into the ATLAS 550 User Manual INSTALLING THE OCTAL AND QUAD FXO MODULES Figure 2 1 represents the actions required to install the module prop...

Page 16: ...ad FXO Modules Step Action 1 Remove the cover plate from the appropriate option slot in the ATLAS 550 rear panel 2 Slide the module into the option slot until the module is firmly positioned against t...

Page 17: ...3 Failed Self Test If the module fails self test a message displays on the terminal menu self test log See the ATLAS 550 User Manual for details Operation Alarms The red ALARM LED located with the Mod...

Page 18: ...Chapter 2 Installation 2 4 Octal and Quad FXO Modules User Manual 61200310L1 1...

Page 19: ...minal attached to the ATLAS 550 Base Unit s control port or a Telnet session established through the Base Unit s Ethernet port The ATLAS 550 User Manual provides detailed instructions on each of these...

Page 20: ...play as FXO 8 under TYPE MODULES MENU The ATLAS 550 system controller automatically detects the presence of the Octal and Quad FXO Modules when they are installed in the system To see the menus for th...

Page 21: ...a system before actually installing modules by simply specifying the module that you want to install in each slot If you intentionally leave a slot empty mark it as EMPTY to avoid get ting a message t...

Page 22: ...This parameter allows an installed module to be marked as offline which may be useful in system troubleshooting If you choose OFFLINE the module will not be in alarm condition but will display OFFLINE...

Page 23: ...umber serial number and assembly revision PART NUMBER Displays the part number of the module SERIAL NUMBER Displays the serial number of the module ASSEMBLY REVISION Displays the assembly revision FIR...

Page 24: ...cted TEST LC NO BATTERY FXO port in test Loop Closed test selected No Loop Battery detected TEST LC T R ROLLED FXO port in test Loop Closed test selected Reverse T R polarity detected TEST RING GND FX...

Page 25: ...ne into the following locations based on test selection NEAR sends the tone out the 2W FXO port while FAR sends the tone into the digital PCM stream of the ATLAS 550 controller These tests are useful...

Page 26: ...s FACTORY RESTORE and RUN SELFTEST FACTORY RESTORE You can restore the factory default settings for Octal and Quad FXO Mod ules by pressing F either while the cursor is over the SLT number this action...

Page 27: ...ble when using terminal mode To access these options select DIAL PLAN from the top level menu Figure A 1 Dial Plan Menus OCTAL AND QUAD FXO MODULES INTERFACE CONFIGURATION The following sections descr...

Page 28: ...START and GROUND START LOOP START Defines to the ATLAS 550 the most common 2W supervision GROUND START Defines to the ATLAS 550 the 2W supervision used by some PBXs DIGIT SUPPRESSION Write security 3...

Page 29: ...UMBER Write security 3 Read security 5 Defines the number to use to determine which user endpoint should receive the incoming call when the Network connection does not provide DID digits This field on...

Page 30: ...dpoints is 0 and all accept numbers is 0 With default values all calls are routed based only on the dialed number Multiple endpoints can have the same SOURCE ID When creating the CALL ACCEPT list spec...

Page 31: ...dware revision 3 5 I Idle Status 3 5 Ifce Config A 1 Inactive Status 3 5 Info 3 5 initialization 2 2 installing the module 2 1 Interface Configuration A 1 introducing the module 1 1 L limited product...

Page 32: ...3 4 Offline No Response 3 4 Online 3 4 Reverse Battery 3 6 Test 3 6 Test LC No Battery 3 6 Test LC T R Rolled 3 6 Test LC T R OK 3 6 Test LO 3 6 Test Ring GND 3 6 Tip Open 3 6 Status Status 3 5 Strip...

Page 33: ...repair is needed Technical Support will coordinate with the Customer and Product Service CAPS department to issue an RMA number For information regard ing equipment currently in house or possible fees...

Page 34: ......

Reviews: