Chapter 3. Operation
61200060L1-1
TSU User Manual
3-11
These fields cannot be edited, only cleared as previously
discussed. Only the user copy of performance data is cleared.
Continue with standard operating procedures to exit the
display.
SES
-
Number of Severely Errored Seconds
ES
-
Number of Errored seconds
%AV
-
% of Available seconds
%EF
-
% of Error free seconds
CVs
-
Number of Code Violations
1 ) S E S 1 5 M I N / 2 4 H R
1 0 / 1 2 0
15 Minutes
Data Values
24 Hours
Since only the user’s copy of performance data is cleared by the
TSU, the data displayed here might be different from the data being
sent to the network as PRM data.