![ADTRAN 1181413L2 Installation And Maintenance Manual Download Page 56](http://html1.mh-extra.com/html/adtran/1181413l2/1181413l2_installation-and-maintenance-manual_2854671056.webp)
Control Port Operation
HDSL4 for General Distribution Installation and Maintenance Practice
46
61223HDSL4L2-5C
Figure 41. Troubleshooting Guidance
General Information
Selecting the General Information option from the Troubleshooting screen accesses the
General Information Screen (
) that summarizes the deployment guidelines
necessary to provision this HDSL4 circuit.
Figure 42. General Information Screen
Circuit ID: 03/09/05 09:29:45
Press ESC to return to previous menu
DSX-1 Loss of Signal (Red Alarm)
- Patch test set REC jack into H4TUC MON TX jack to verify integrity of
signal to the H4TUC from the network (verify test set in MON mode).
- If signal to H4TUC is missing, insert test set at DSX panel IN Jack connecting
toward H4TUC (to verify wiring between DSX and H4TUC shelf). Check H4TUC to
verify DSX-1 LOS alarm is cleared. This verifies TX(out) and RX(in) pairs are
not swapped.
- If signal from DSX OK, verify cross-connect wiring at DSX panel is turned over
(OUT to IN) and (IN to OUT).
-If DSX wiring OK, connect test set REC to the DSX MON, network side equipment,
to verify signal from network (verify test set to MON). If no signal,
troubleshoot office problems.
For Total Access cards verify the following:
- Provisioning>Network Source is configured correctly for Mux or DSX operation.
- Provisioning>Service State is not configured for OOS-Unassigned.
- Mux card is mapped correctly.
- Mux card is functioning correctly.
Circuit ID: 03/09/05 09:29:45
Press ESC to return to previous menu
HDSL4 Loop Guidelines for optimum operation
-------------------------------------------
Non-loaded cable pair
Single bridge tap < 2Kft
Total bridge taps < 2.5Kft
Power influence <= 80 dBrnC
Longitudinal Balance >= 60dB (If using Wideband test at 196 Khz >= 40dB)
Foreign DC Voltage (t-r,t-g,r-g) < 3VDC
Loop Resistance <= 1000 ohms 1st segment
Loop Resistance <= 920 ohms 2nd segment
The following guidelines are provided as a recommendation and may be superseded
by internal deployment guidelines
Margin >= 6 dB
Attenuation (1st Segment) H4TUC <= 31 dB, H4TUR/H4R <= 33 dB
Attenuation (2nd or 3rd Segment) H4TUR/H4R <= 30 dB