![ADTEK CM1-CT Manual Download Page 7](http://html1.mh-extra.com/html/adtek/cm1-ct/cm1-ct_manual_2854176007.webp)
■
Communication Table
User Level
Name
Address
Range
Explain
Initial Write/Read Note
conut pv
0000h
0001h
-199999~999999 Present Value
R
Name
Address
Range
Explain
Initial
R/W
Note
count pv
0000h
0001h
-199999~999999 Present Value
R/W
Input Group
Name
Address
Range
Explain
Initial
R/W
Note
intyp
0002h
0~4
Input Type
0:UP 1:DOWN 2:AB.P-2 3:IDV 4:CMD
R/W
0
R/W
0
R/W
1
R/W
0
pVtyp
0003h
0~1
PV Display Type
0:CNT 1:METER
ppr
0004h
0005h
1~999999
Output Pulse per Rotation
eunit
0006h
0~3
Unit of Length
0:M 1:CM 2:YARD 3:FOOT
R/W
1
diamt
0007h
0008h
0.0001~9.99999
R/W
1
cntsf
0009h
000Ah
0.0001~9.99999
R/W
0
ttldp
000Bh
0~3
Decimal Point of Display
0:0 1:0.1 2:0.00 3:0.000
R/W
0
oflmd
000Ch
0~1
Process after Over
fl
ow
0:OVFL 1:RCYCL
R/W
1
ecikey
000Dh
0~1
ECI Function Key Enable
0:YES 1:NO
R/W
1000
Pcode
000Eh
0000~9999
Pass Code
RS485 Group
Name
Address
Range
Explain
Initial
R/W
Note
adres
000Fh
1~247
Station address
R/W
1
R/W
3
R/W
1
baud
0010h
0~5
Baud rate
0:1200 1:2400 2:4800 3:9600
4:19200 5:38400
prity
0011h
0~3
Parity check
0:N-8-1 1:N-8-2 2:O-8-1 3:E-8-1
INIT Group
Name
Address
Range
Explain
Initial
R/W
Note
init
0012h
0000~9999
Meter Initialization
R/W
0
7170
6
Axis Diameter setting
Counting Constant setting