SPECIFICATIONS
8.1
System Specifications
Table 8-1
System Specifications
Parameters
Specifications
Remarks
DL
UL
Frequency Range
(MHz)
700
758-768 (FCC & IC)
769-775 (FCC only)
788-798 (FCC & IC)
799 -805 (FCC only)
800
854-861 (FCC only)
809-816 (FCC only)
Composite Output Power
27 dBm
24 dBm
In case of 700/800
simultaneous output, the
3dB rule is adapted
* Tolerance : +/-1 dB
System Gain (dB)
55-85
55-85
* Tolerance : +/-1 dB
Gain Control Range/Step(dB)
30/0.5
30/0.5
ALC range(dB)
30
30
Support of Filter BW
2 non-contiguous Sub-band of
3/5/6/10/17/18(MHz)
Filter Roll-off
60dBc@Filter Bandwidth Edge +1MHz
Squelch (UL)
-95~-80dBm in 5dB steps
Spurious
FCC meet
Passband Ripple
±2 dB
Noise Figure @ Max gain
≤7dB
System Group Delay
≤7us
Power
110 -240 VAC, 60 Hz (Free Voltage)
Power Consumption
<130W
No damage Max Input Power
+10dBm
Impedance
50 Ohm
VSWR
<
1.5:1
Operating at Ambient Temperature
-22°F to +122°F (-30°C to +50°C)
Dimensions W x D x H
10.13x7.56x19.7 in (257x192x500 mm)
w/o mount bracket
Weight
35.7 lbs (16.2kg)
w/o mount bracket
RF Connector
4.3-10 (Female, 2EA) : Donor Ant, Server Ant
SMA (Female, 2EA) : -30dB Output Monitor
1/2“ Liquid Tight Conduit Connector
Hole
AC Line, Battery Line, External Alarm Line(AAI)
Hole size : 7/8”
Enclosure
IP66