Advanced RF Technologies, Inc.
23
Figure 3-4 NMS AAI
NMS has 5 external alarms out interface pins on the front panel.
Table 3-2
NMS AAI Specifications
AAI Alarm Status
Output
Normal
High Impedance (Open)
Alarm
Low Impedance (Short)
3.1.1.3
Ethernet Port
The Ethernet port can be used to communicate directly with the ADXV-HPR using a RJ-45 crossover cable or can
also be used to connect the ADXV-HPR to an external modem box.
Figure 3-5 Ethernet Port
3.1.1.4
Host/Remote Switch
The Host/Remote Switch allows the user to switch the default Repeater IP, Subnet Mask, and Gateway of the
repeater to an alternative setup. These settings can be adjusted by logging into the ADXV-HPR in HOST mode and
configuring the settings under the Modem Box Setting section under the Install Page of NMS.
Once the settings are set, flipping the switch to the REMOTE position will reboot NMS module with the new
alternate settings.
Please note that when the NMS is set to the REMOTE position, DHCP is disabled and the NMS will
not automatically assign an IP address to any device that connects directly to the NMS.
01
02
03
04
05
P(+)
N(-)
LAN1
LAN0
Summary of Contents for ADXV-HPR
Page 8: ...Advanced RF Technologies Inc viii Figure 9 2 ADXV HPR Drawing 60 ...
Page 39: ...Advanced RF Technologies Inc 39 Figure 6 1 HE Installation Procedure ...
Page 41: ...Advanced RF Technologies Inc 41 Figure 6 2 ADXV HPR Installation Procedure ...
Page 51: ...Advanced RF Technologies Inc 51 Figure 7 12 New Account ...
Page 59: ...Advanced RF Technologies Inc 59 9 MECHANICAL DRAWING 9 1 HE Figure 9 1 HE Drawing ...
Page 60: ...Advanced RF Technologies Inc 60 9 2 ADXV HPR Figure 9 2 ADXV HPR Drawing ...