Advanced RF Technologies, Inc.
36
6.2.2
RU Installation Procedure
The ADXD RU chassis mounts in a standard 19” (483mm) equipment rack. Allow clearance of 3” (76mm) at
the front and rear, and 2” (51mm) on both sides for air circulation. No top or bottom clearance is required.
Consideration:
-
Eight mounting holes are located on 4 corners of ADXD RU to attach it to the 19” rack. The
ADXD RU must be securely attached to a rack that can support the weight of the ADX.
Procedure
-
The following steps should be followed while mounting the ADXD RU
Verify that the RU and Mounting holes are in good condition
Set the ADXD DAS RU against the 19”rack and secure the unit with screws
Verify that ADXD RU is securely attached
Connect the GND cable
Connect the RF coaxial cable
Connect the Power
Connect the Optic cable