background image

Leading

EDGE COMPUTING

VPX3001 Series

Performance Rugged Conduction Cooled

3U VPX 3rd Gen Intel® Core™ i7

Processor Blade

Manual Rev.: 

1.0

Revision Date: 

June 3, 2019

Part No: 

50-15102-2000

Summary of Contents for VPX3001 Series

Page 1: ...Leading EDGE COMPUTING VPX3001 Series Performance Rugged Conduction Cooled 3U VPX 3rd Gen Intel Core i7 Processor Blade Manual Rev 1 0 Revision Date June 3 2019 Part No 50 15102 2000...

Page 2: ...ii Revision History Leading EDGE COMPUTING Revision History Revision Release Date Description of Change s 1 0 2019 06 03 Initial release...

Page 3: ...of the use or inability to use the product or documentation even if advised of the possibility of such damages Environmental Responsibility ADLINK is committed to fulfill its social responsi bility to...

Page 4: ...e harm For more information go to www P65Warnings ca gov Trademarks Product names mentioned herein are used for identification pur poses only and may be trademarks and or registered trademarks of thei...

Page 5: ...ge Contents 6 2 Specifications 7 2 1 VPX3001 Blade Specifications 7 2 2 VPX R3001 RTM Specifications 9 2 3 Power Consumption 10 3 Functional Description 11 3 1 Processors 11 3 2 Chipset 13 3 3 Intel T...

Page 6: ...Installation 38 7 Utilities 39 7 1 Watchdog Timer 39 8 BIOS Setup 45 8 1 Starting the BIOS 45 8 2 Main Setup 50 8 3 Advanced BIOS Setup 51 8 4 Chipset Setup 69 8 5 Boot Settings 73 8 6 Security Setup...

Page 7: ...ure 1 1 VPX3001 Functional Block Diagram 3 Figure 1 2 VPX R3001 RTM Functional Block Diagram 4 Figure 4 1 VPX3001 Board Layout 17 Figure 4 2 VPX3001 Mechanical Dimensions 18 Figure 4 3 VPX3001 Front V...

Page 8: ...viii List of Figures Leading EDGE COMPUTING This page intentionally left blank...

Page 9: ...List of Tables ix VPX3001 List of Tables Table 2 1 VPX3001 Blade Specifications 7 Table 2 2 VPX R3001 RTM Specifications 9...

Page 10: ...x List of Tables Leading EDGE COMPUTING This page intentionally left blank...

Page 11: ...32GB SLC SATA solid state drive Rear I O via P1 and P2 includes 2x 1000BASE T or 2x 1000BASE BX BOM option 1x SATA 6 Gb s 1x SATA 3 Gb s 2x USB 2 0 6x GPIO VGA 1x RS 232 and 1x RS 232 422 A VPX R3001...

Page 12: ...1 X Onboard PCI Express x8 XMC site with VITA 46 9 rear I O X Onboard 32GB SLC SATA Solid State Drive X Data Plane VITA 46 4 PCIe 2 0 x8 or 2x PCIe 2 0 x4 to P1 supports NTB function X Control Plane...

Page 13: ...x8 PCIe Switch PEX8619 PCIe 2 0 x8 LPC F81216D UART UART RS 232 UART 32GB Flash 1x SATA 3Gb s BIOS PCIe 2 0 x4 GbE Intel 82580EB 1000BASE T 1000BASE T 1000BASE BX 1000BASE BX 2x USB 2 0 1x SATA 6Gb s...

Page 14: ...VS3 DC5V 16A Slot DC3V_AUX 1A Slot DC12V_AUX 1A Slot DC 12V_AUX 1A Slot VBAT NVMRO SYSRESET 1000BASE BX x2 ports SERDES optional 1000BASE BX 1000BASE T 1000BASE T x2 ports SATA x1 port SATA VGA x1 por...

Page 15: ...ze Code Z M8 Onboard 8GB DDR3 1333 1600 memory Z M16 Onboard 16GB DDR3 1333 1600 memory C SATA NAND Flash Size Code Z S32 Onboard 32GB D Ruggedized Level Code Z R1 Conduction Cooled version with confo...

Page 16: ...d memory specifications will differ depending on options selected Z Thermal module is assembled on the board Rear Transition Module X VPX R3001 RTM Test Backplane X tBP VPX3000 test backplane NOTE NOT...

Page 17: ...x 160mm P0 P1 P2 connectors alignment key 1 2 equipped Processor Intel Core i7 3612QE Processor 2 1 GHz 6MB LLC cache FCBGA1023 TDP 35W Intel Core i7 3555LE Processor 2 5 GHz 4MB LLC cache FCBGA1023 T...

Page 18: ...Interface 1x SATA ports 2x USB 2 0 1x RS 232 6x GPIO PCIe x8 2x 1000BASE T Gigabit Ethernet Ports or 2x 1000BASE BX SerDes Port P2 Interface VGA RS 232 422 XMC X24s X8d X12d Environmental Operating T...

Page 19: ...PX Mechanical 100mm x 80mm Faceplate I O VGA port 2x 1000BASE BX connectors Onboard Interfaces 2x 1000BASE T vertical connectors 1x SATA 6Gb s ports 2x 5 pin header for RS 232 x2 2x 5 pin header for U...

Page 20: ...re Intel Core i7 3612QE 2 1 GHz 6MB cache 35W Windows 7 Typical power consumption running BurnInTest at 100 loading Windows 7 Max loading power consumption running Intel TAT test at 100 loading Item B...

Page 21: ...latform enables higher performance lower cost easier valida tion and improved x y footprint The processor includes an inte grated display engine processor graphics integrated memory controller and int...

Page 22: ...Bit X Intel VT x with Extended Page Tables EPT Interfaces X Dual channel DDR3 memory with one channel of unbuffered SODIMM and one channel of soldered SDRAM X Memory DDR3 data transfer rates of 1333 M...

Page 23: ...rollers with independent DMA operation on up to six ports and SATA 6 0 Gb s up to two ports X Supports USB 2 0 USB 3 0 X USB host interface with two EHCI high speed USB 2 0 Host controllers and two ra...

Page 24: ...veness for short bursty usage conditions Turbo Mode availability is independent of the number of active cores however the Turbo Mode frequency is dynamic and depen dent on the instantaneous applicatio...

Page 25: ...X8d X12d 3 6 Real Time Clock The Intel QM77 PCH contains a Motorola MC146818B compati ble real time clock RTC with 256 bytes of RAM The real time clock performs two key functions keeping track of the...

Page 26: ...16 Functional Description Leading EDGE COMPUTING This page intentionally left blank...

Page 27: ...igure 4 1 VPX3001 Board Layout CPU Intel Core Processor SSD 32GB SATA NAND flash PCH Intel QM77 PCH XMC XMC connectors PCIe Switch Pericom PEX8619 Bridge Memory DDR3 memory chips LAN Intel 82580EB Eth...

Page 28: ...4 2 VPX3001 Mechanical Drawing Figure 4 2 VPX3001 Mechanical Dimensions Figure 4 3 VPX3001 Front View Power LED LED Color Condition Indication Power Green OFF System is off ON System is on 99 85 160 1...

Page 29: ...VPX3001 Board Interfaces 19 VPX3001 System Reset Resets the system RTC Reset Resets BIOS settings to factory default settings...

Page 30: ...5 RXP4 RXN4 3 3V RXP5 RXN5 VPWR 6 GND GND TMS GND GND 12V 7 RXP6 RXN6 3 3V RXP7 RXN7 VPWR 8 GND GND TDI GND GND 12V_AUX 9 NC NC NC NC NC NC 10 GND GND TDO GND GND GA0 11 TXP0 TXN0 MBIST TXP1 TXN1 VPWR...

Page 31: ...P2 C12 P2 B12 NC 8 GND GND P2 E1 GND GND P2 B1 9 P2 E13 P2 D13 P2 D1 P2 B13 P2 A13 P2 A1 10 GND GND P2 F2 GND GND P2 C2 11 P2 E9 P2 D9 P2 E2 P2 B9 P2 A9 P2 B2 12 GND GND P2 E3 GND GND P2 B3 13 P2 F10...

Page 32: ...P1_VBAT GND L2 TX L2 TX GND L2 RX L2 RX 4 GND L3 TX L3 TX GND L3 RX L3 RX GND 5 SYSCON GND L4 TX L4 TX GND L4 RX L4 RX 6 GND L5 TX L5 TX GND L5 RX L5 RX GND 7 NC GND L6 TX L6 TX GND L6 RX L6 RX 8 GND...

Page 33: ...J16 C18 J16 C19 AGND J16 F18 J16 F19 AGND 7 VGA0_VSYNC GND J16 A1 J16 B1 GND J16 D1 J16 E1 8 GND J16 A3 J16 B3 GND J16 D3 J16 E3 GND 9 VGA0_HSYNC GND J16 A11 J16 B11 GND J16 D11 J16 E11 10 GND J16 A13...

Page 34: ...24 VPX3001 Board Interfaces Leading EDGE COMPUTING This page intentionally left blank...

Page 35: ...on board Two RJ 45 LAN ports two ports SERDES optional One SATA 6Gb s ports One RS 232 port on board One VPX JTAG port One VGA ports GPIO 16 pin header Dimension 187x199 7mm Buttons One reset button E...

Page 36: ...or 7 pin VGA VGA connector DB 15 1000BASE BX 1000BASE BX Connector JTAG VPX JTAG Connector USB 2 0 USB 2 0 pin header GPIO GPIO connector RS 232 RS 232 pin header 1000BASE T 1000BASE T connectors RJ 4...

Page 37: ...ments Rear I O Connectors VGA Connector BX Connectors Signal Name Pin Pin Signal Name Red 1 2 Green Blue 3 4 N C GND 5 6 GND GND 7 8 GND 5V 9 10 GND N C 11 12 CRTDATA HSYNC 13 14 VSYNC CRTCLK 15 Pin G...

Page 38: ...UTING Onboard Connectors Gigabit Ethernet Connectors RJ 45 CN9 10 RS 232 Header CN20 Pin Signal 1 MX0 2 MX0 3 MX1 4 MX2 5 MX2 6 MX1 7 MX3 8 MX3 Pin Signal 1 N C 2 P1_SOUT 3 P1_SIN 4 N C 5 GND 6 N C 7...

Page 39: ...Header CN22 USB 2 0 Connector CN30 Pin Signal 1 P0_TCK 2 GND 3 P0_TDO 4 NC 5 P0_TMS 6 P3V3_PSU 7 P3V3_PSU 8 P0_TRST 9 P0_TDI 10 GND Pin Signal 1 P5V_USB 2 P5V_USB 3 USB_N6_L 4 USB_N0_L 5 USB_P6_L 6 U...

Page 40: ...PX R3001 RTM Leading EDGE COMPUTING SATA Connector CN32 36 VPX SMBus 2 3 CN95 Pin Signal 1 GND 2 TXP 3 TXN 4 GND 5 RXN 6 RXP 7 GND Pin Signal 1 IPMB_DAT 2 GND 3 IPMB_CLK 4 P5V_PSU 5 P5V_PSU 5 1 7 6 4...

Page 41: ...IO LEDs Pin Signal 1 SMBUS_GPIO0 2 GND 3 SMBUS_GPIO1 4 GND 5 SMBUS_GPIO2 6 GND 7 SMBUS_GPIO3 8 GND 9 SMBUS_GPIO4 10 GND 11 SMBUS_GPIO5 12 GND 13 GND 14 GND 15 GND 16 GND LED Signal LED1 GPIO0 LED2 GPI...

Page 42: ...C8 GND GND JN6 F8 9 JN6 A9 JN6 B9 JN6 C9 JN6 D9 JN6 E9 JN6 F9 10 GND GND JN6 C10 GND GND JN6 F10 11 JN6 A11 JN6 B11 JN6 C11 JN6 D11 JN6 E11 JN6 F11 12 GND GND JN6 C12 GND GND JN6 F12 13 JN6 A13 JN6 B1...

Page 43: ...4 I2C_CLK I2C_DAT GND NC GND NC NC 5 NC NC GND NC GND IPMB_CLK IPMB_DAT 6 NC NC GND NC GND NC NC 7 TCK GND TDO TDI GND TMS TRST 8 GND NC NC GND NC NC GND 9 NC GND NC NC GND NC NC 10 GND NC NC GND NC N...

Page 44: ...I1_C GND 7 MASK_RESET L GND MDI2_B BX1_T MDI2_B BX1_T GND MDI2_A BX1_R MDI2_A BX1_R 8 GND MDI2_D BX0_T MDI2_D BX0_T GND MDI2_C BX0_R MDI2_C BX0_R GND 9 VGA_R GND JN6 C8 JN6 C9 GND JN6 F8 JN6 F9 10 GND...

Page 45: ...N6 A13 JN6 B13 GND JN6 D13 JN6 E13 GND 3 COM2_RX GND JN6 A5 JN6 B5 GND JN6 D5 JN6 E5 4 GND JN6 A7 JN6 B7 GND JN6 D7 JN6 E7 GND 5 DDC_CLK GND JN6 A9 JN6 B9 GND JN6 D9 JN6 E9 6 GND JN6 A15 JN6 B15 GND J...

Page 46: ...36 VPX R3001 RTM Leading EDGE COMPUTING This page intentionally left blank...

Page 47: ...ight resistance may be felt when inserting the module If the resistance it too strong check if there are wedge lock screwed or if the board s connector pins are not properly aligned with connectors on...

Page 48: ...zip 4 Install the graphics driver and utilities by extracting and running the program in Intel_HD_Graphics_Family_ WIN7_64_ 15 28 12 64 2932 zip 5 Install the audio drivers and utilities by extractin...

Page 49: ...perated by IPMI commands Watchdog Timer IPMI Commands The following section describes the IPMI commands for controlling watchdog timer WDT functions For more details about IPMI commands please refer t...

Page 50: ...cription Request 0 18h NetFn LUN 1 24h Defined command 2 7 1b don t log 6 1b don t stop timer 5 3 reserved 2 0 timer use 000b reserved 001b BIOS FRB2 010b BIOS POST 011b OS Load 100b SMS OS 101b OEM 1...

Page 51: ...er Use Expiration flags clear 6 00h ffh LS byte 100 ms count Initial countdown value 7 00h ffh MS byte 100 ms count Initial countdown value Response 0 Complete Code 00h means OK Action Byte Value Desc...

Page 52: ...111b reserved Timer Actions 3 1h ffh 1h based Pre timeout interval in seconds 4 7 reserved 6 reserved 5 OEM 4 SMS OS 3 OS Load 2 BIOS POST 1 BIOS FRB2 0 reserved 0b leave alone 1b clear timer use expi...

Page 53: ...OS Configure WDT Parameters 0x40 Don t stop timer 0x01 Hard Reset 0x01 Pre timeout interval in 1 second 0x08 Timer Use Expiration flags clear by OS Load 0x50 80 count 100ms 80 8000ms 8 seconds 18 00 2...

Page 54: ...44 Utilities Leading EDGE COMPUTING This page intentionally left blank...

Page 55: ...ey on your keyboard when you see the ADLINK Logo Quiet Boot enabled or the text prompt Press DEL to run Setup Quiet Boot disabled 3 After you press the Delete key the main BIOS setup menu displays You...

Page 56: ...The Main BIOS setup menu screen has two main frames The left frame displays all the options that can be configured Grayed options cannot be configured Blue options can be The right frame displays the...

Page 57: ...e Left and Right Arrow keys allow you to select a setup screen For example Main screen Advanced screen Chipset screen and so on Up Down The Up and Down Arrow keys allow you to se lect a setup item or...

Page 58: ...o set the previous values settings of the BIOS press the F2 key on your keyboard It is located on the upper row of a stan dard 101 keyboard The previous values settings allow the motherboard to boot u...

Page 59: ...key to select Cancel and then press the Enter key to abort this function and return to the previous screen ESC The Esc key allows you to discard any changes you have made and exit the Setup Press the...

Page 60: ...setup screen reports BIOS and Board version information System Time System Date Use this option to change the system time and date Highlight Sys tem Time or System Date using the Arrow keys Enter new...

Page 61: ...up screen You can select any of the items in the left frame of the screen such as SuperIO Configuration to go to the sub menu for that item You can display an Advanced BIOS Setup option by highlightin...

Page 62: ...d keys to change the value of the selected option A description of the selected item appears on the right side of the screen The settings are described on the follow ing pages An example of the CPU Co...

Page 63: ...s When Enabled the processor will limit the maximum CPUID input value to 03h when queried even if the processor supports a higher CPUID input value When Disabled the processor will return the actual m...

Page 64: ...ATA Configuration screen is shown below SATA Controller s Enable or disable SATA device SATA Mode Selection The SATA can be configured as a legacy IDE RAID and AHCI mode Aggressive LPM Suppor Enable P...

Page 65: ...BIOS Setup 55 VPX3001 SATA Port 0 2 Display SATA device name string SATA Device Type Identify the SATA port is connected to Solid State Drive or Hard Disk Drive...

Page 66: ...56 BIOS Setup Leading EDGE COMPUTING 8 3 3 PCH FW Configuration You can use this screen to get the Intel ME FW version...

Page 67: ...n disables legacy support if no USB devices are connected Disable option will keep USB devices available only for EFI applications Set this value to Enabled Disabled Auto USB 3 0 Support To enable or...

Page 68: ...IOS Setup Leading EDGE COMPUTING EHCI Hand off This is a workaround for OSes without EHCI hand off support The EHCI ownership change should be claimed by the EHCI driver Set this value to Enabled Disa...

Page 69: ...itored hard ware devices components such as voltages and temperatures CPU Temperature Display current CPU temperature System Temperature Display current System thermal diode temperature 3 3V Display c...

Page 70: ...down Arrow keys to select an item Use the and keys to change the value of the selected option The settings are described on the following pages The screen is shown below Serial Port 1 2 3 4 Configurat...

Page 71: ...description of the selected item appears on the right side of the screen The settings are described on the fol lowing pages An example of the Serial Port Console Redirection screen is shown below Con...

Page 72: ...se for console redirection The options are 115200 57600 38400 19200 9600 Data Bits Select the data bits you want the serial port to use for console redirection Set this value to 7 8 Parity Set this op...

Page 73: ...NSI VT100 terminals Set this value to Enabled Disabled Recorder Mode When this mode is enabled only text will be sent This is to capture terminal data Set this value to Enabled Disabled Resolution 100...

Page 74: ...ed to the network or the network is not available In short EMS allows for remote management of a Windows Server OS through a serial port Out of Band Mgmt Port Microsoft Windows emergency management se...

Page 75: ...TS CTS Data Bits This is a display only function providing information about the frame width for the Out of Band Management Parity This is a display only function providing information about the parit...

Page 76: ...66 BIOS Setup Leading EDGE COMPUTING 8 3 8 Network Stack Enable or disable the UEFI network stack...

Page 77: ...SpeedStep Set this value to Enabled Dis abled Turbo Mode Set this option to enable or disable turbo mode Set this value to Enabled Disabled CPU C3 Report Enable or disable CPU C3 ACPI C2 report to OS...

Page 78: ...DP Lock Lock the Config TDP Control register Set this value to Enabled Disabled Long duration power limit Long duration power limit in watts 0 means use factory default Long duration maintained Time w...

Page 79: ...pset Setup Select the Chipset tab from the setup screen to enter the Chipset BIOS Setup screen You can select any of Chipset BIOS Setup options by highlighting it using the Arrow keys The Chipset BIOS...

Page 80: ...70 BIOS Setup Leading EDGE COMPUTING 8 4 1 PCH IO Configuration SB CRID Enable or disable SB Compatible Revision ID High Precision Timer Enable or disable the High Precision Event Timer...

Page 81: ...ology for Directed I O Set this value to Enabled Disabled Primary Display Select which graphics device should be the primary display Set this value to Auto IGFX PCI PLX_8619 PCIe Port1 3 Support Selec...

Page 82: ...ING Memory Configuration Memory Frequency Limit Set the Memory Frequency Limit in MHz Options Auto default 1067 1333 1600 1867 2133 2400 and 2667 Memory Remap Enable or disable memory remap above 4G S...

Page 83: ...oot BIOS Setup option by highlight ing it using the Arrow keys The Boot Settings screen is shown below Quiet Boot X Disabled Set this value to allow the computer system to display the POST messages X...

Page 84: ...controls if CSM will be launched Set this value to Always Never Boot option filter This option controls what devices system can boot to Set this value to UEFI and Legacy Legacy only UEFI only Launch P...

Page 85: ...trols the execution of UEFI and Legacy Video OpROM Set this value to Do not launch UEFI only Legacy only Other PCI device ROM priority For PCI devices other than Network Mass storage or Video defines...

Page 86: ...If only the administrator s password is set then this only limits access to setup and is only asked for when entering setup If only the user s password is set then this is a power on password and must...

Page 87: ...tab from the setup screen to enter the Save Exit BIOS Setup screen You can display an Exit BIOS Setup option by highlighting it using the Arrow keys The Save Exit BIOS Setup screen is shown below Sav...

Page 88: ...set Reset system setup without saving any changes Save Changes Save changes done so far to any of the setup options Discard Changes Discard changes done so far to any of the setup options Restore Chan...

Page 89: ...changes done so far as user defaults Restore User Defaults Save changes done so far to any of the setup options Launch EFI Shell from Filesystem Device Attempts to Launch EFI Shell application Shellx...

Page 90: ...80 BIOS Setup Leading EDGE COMPUTING This page intentionally left blank...

Page 91: ...column indicates if a particular command is manda tory or optional for IPMI 2 0 and VITA 46 11 Command Name IPMI v2 0 Specification Section NetFn CMD IPM Device Global Commands Reserved NA App 06h 00...

Page 92: ...erve SEL 25 4 Storage 0Ah 42h Get SEL Entry 25 5 Storage 0Ah 43h Add SEL Entry 25 6 Storage 0Ah 44h Clear SEL 25 9 Storage 0Ah 47h Get SEL Time 25 10 Storage 0Ah 48h Set SEL Time 25 11 Storage 0Ah 49h...

Page 93: ...Ah Get FRU State Policy Bits VITA section 10 1 3 8 VITA 0Bh Set FRU Activation VITA section 10 1 3 10 VITA 0Ch Get Device Locator Record ID VITA section 10 1 3 11 VITA 0Dh Get Fan Speed Properties VIT...

Page 94: ...sor Reading Command 0 Hot Swap N A FRU State Sensor 1 IPMB Physical N A System IPMB link sensor 2 FRU 0 Health N A FRU Health Sensor 3 FRU 0 Voltage N A FRU Voltage Sensor 4 FRU 0 Temp N A FRU Tempera...

Page 95: ...3h Event Reading 6Fh sensor specific Timeout action 000b no action 001b Hard Reset 000b Power Down 011b Power Cycle 100b 111b reserved 24 CPU Core Temp TBD TBD 25 Chassis Hot Swap N A TBD 26 RTM Hot S...

Page 96: ...MITOOL 06 19 2018 01 07 39 System Boot Initiated Initiated by warm reset IPMI SPEC v2 0 Table 42 1 Event Reading Type Code Ranges Sensor Type Code Sensor Class Description Sensor specific 0x1D Discret...

Page 97: ...tion Board Info Mfg Date Time xx xx xxxx Manufacturer ADLINK Product Name VPX 3XXX Serial Number PPSxxxxxxx Part Number xxxxxxxxxxxx Product Info Manufacturer ADLINK Product Name VPX 3XXX Part Model N...

Page 98: ...Second Generation v2 0 Rev 1 0 2004 2 12 X IPMI Platform Management FRU Information Storage Defi nition V1 0 Rev1 1 1999 9 27 X Microsemi PPS BMR A2F ATCA Software Architecture Technical Specification...

Page 99: ...rn off power and unplug any power cords cables X To avoid electrical shock and or damage to equipment Z Keep equipment away from water or liquid sources Z Keep equipment away from high heat or high hu...

Page 100: ...must be serviced by authorized technicians when Z The power cord or plug is damaged Z Liquid has penetrated the equipment Z It has been exposed to high humidity moisture Z It is not functioning or doe...

Page 101: ...8 360 0200 Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China...

Reviews: