3.3 PXI-8565 Layout, Connectors and Jumpers

Figure 3-3: PCI-8565 Mechanical Layout

Connector/Jumper/LED

Description

J1

Spread spectrum clock control

CN1

PCI Express serial link connector

D1

Serial Link Status LED

Table  3-1: PXI-8565 Connectors, Jumpers and LED

Summary of Contents for EC-8560

Page 1: ...Advance Technologies Automate the World Manual Revision 2 00 Revision Date April 08 2008 Part No 50 1V001 1000 EC 8560 PXI 8565 ExpressCard to PXI Extension Kit User s Manual...

Page 2: ...EC 8560 PXI 8565 ADLINK Technology Inc User s Manual Copyright 2008 ii Revision History Revision Release Date Description of Change s 2 00 2008 04 08 Document Created Initial Release...

Page 3: ...responsibility to global environmental preservation through compliance with the Euro pean Union s Restriction of Hazardous Substances RoHS direc tive and Waste Electrical and Electronic Equipment WEEE...

Page 4: ...ciated product s Chapter 1 Introduction Introduces the ExpressCard to PXI Extension Kit overview its features applications archi tecture block diagrams and package contents Chapter 2 Getting Started P...

Page 5: ...tasks and instructions properly NOTE NOTE Additional information aids and tips that help users per form tasks CAUTION Information to prevent minor physical injury component damage data loss and or pro...

Page 6: ...nd or the operation of the ExpressCard to PXI Extension Kit This list is prepared in alpha betical order by vendor name then by document title for clarity Vendor s Association s Title Rev PCI SIG PCI...

Page 7: ...8900 Research Drive Irvine CA 92618 USA ADLINK TECHNOLOGY CO LTD BEIJING Sales Service market adlinktech com Telephone No 86 10 5885 8666 Fax No 86 10 5885 8625 Mailing Address Rm 801 Power Creative...

Page 8: ...NK TECHNOLOGY INC SOUTH KOREA Liaison Office Sales Service korea adlinktech com Telephone No 82 2 2057 0565 Fax No 82 2 2057 0563 Mailing Address 402 Dongsung B D 60 12 Nonhyeon dong Gangnam gu Seoul...

Page 9: ...emarks iii Using this Manual iv Conventions v Reference Documentation vi Getting Service vii Table of Contents ix List of Figures xi List of Tables xiii 1 Introduction 1 1 1 Overview 1 1 1 1 Controlli...

Page 10: ...ing Laptop Computer to PXI Extension Chassis 10 2 5 Power ON OFF Sequence 12 2 6 LED Status 13 3 Hardware Information 15 3 1 Functional Block Diagram 15 3 2 EC 8560 16 3 3 PXI 8565 Layout Connectors a...

Page 11: ...Installation Diagram 9 Figure 2 4 3 M extension cable ACL EXPRESS 3 10 Figure 2 5 Cabling 3 M Extension Cable to PXI Extension Chassis 11 Figure 2 6 Laptop Computer Connected to a PXI Extension Chass...

Page 12: ...xii EC 8560 PXI 8565 ADLINK Technology Inc User s Manual Copyright 2008 This page intentionally left blank...

Page 13: ...hnology Inc EC 8560 PXI 8565 Copyright 2008 User s Manual List of Tables Table 3 1 PXI 8565 Connectors Jumpers and LED 17 Table 3 2 PXI 8565 J1 Spread Spectrum Clock Control 18 Table 3 3 Optional Exte...

Page 14: ...xiv EC 8560 PXI 8565 ADLINK Technology Inc User s Manual Copyright 2008 This page intentionally left blank...

Page 15: ...host system requiring no additional drivers or software instal lation The host system may be separated from the extension system at up to seven meters using high quality shielded twisted copper cable...

Page 16: ...I slots in the extension system The link between host laptop computer and the external chassis is a PCI Express X1 link that represents a dual simplex communica tions channel consisting of two low vol...

Page 17: ...tance of up to 7 meters X Dimensions ExpressCard 34 108mm W X 34mm H X Power requirements 3 3V 210mA max PXI 8565 on extension PXI chassis X Compliant with PCI to PCI Bridge Architecture Specifica tio...

Page 18: ...software transparency X Compliant with PCI Express Base Specification Revision 1 0a X Compliant with PCI to PCI Bridge Architecture Specifica tion Revision 1 2 X Compliant with PCI Local Bus Specific...

Page 19: ...s such as flat and cross head screwdrivers The ExpressCard to PXI Extension Kit contains several electro static sensitive components that can be easily damaged by static electricity For this reason th...

Page 20: ...e ACL EXPRESS 3 Screw the ACL EXPRESS 3 cable to the EC 8560 3 Insert the EC 8560 into an available ExpressCard slot in your laptop computer Be sure to firmly attach the EC 8560 to the ExpressCard slo...

Page 21: ...ill need a sustaining rack to adequately attach the EC 8560 The sustaining rack adds secure connectivity Refer to the following steps to install the sustaining rack onto the EC 8560 Figure 2 2 EC 8560...

Page 22: ...Getting Started EC 8560 PXI 8565 ADLINK Technology Inc User s Manual Copyright 2008 2 Secure the sustaining rack and insert the assembled EC 8560 and sustaining rack into your ExpressCard 54 normally...

Page 23: ...I chassis system slot 3 Locate your PXI 8565 and remove it from its packaging Please wear anti static gloves and use an anti static surface when handling the card 4 Install the PXI 8565 into the PXI s...

Page 24: ...the PXI extension chassis you may connect the Host Computer and PXI extension chassis with an extension cable 1 Locate your 3 M extension cable One end should already be connected to the EC 8560 Figu...

Page 25: ...nnector of the extension PXI chassis 3 Firmly attach the 3 M extension cable by tightening its retention screws 4 Connect the other end of the 3 M extension cable to the PXI 8565 serial link connector...

Page 26: ...n resource to each one during start up Thus users have to power on the PXI chassis first in order to get appro priate resources from the BIOS To power off the PCI Express to PXI Extension Kit follow t...

Page 27: ...C 8560 and PXI 8565 give power status infor mation The LEDs light up only when the following conditions are met X The extension cable between the EC 8560 Host Laptop Computer and PXI 8565 Extension Ch...

Page 28: ...14 Getting Started EC 8560 PXI 8565 ADLINK Technology Inc User s Manual Copyright 2008 This page intentionally left blank...

Page 29: ...Information 3 1 Functional Block Diagram Figure 3 1 Laptop Computer EC 8560 PXI 8565 Remote PXI Chassis ExpressCard 34 or ExpressCard 54 External Cable PCI Express to PCI Bridge Signal Equalizer PCI...

Page 30: ...ht 2008 3 2 EC 8560 The EC 8560 is an ExpressCard 34 form factor module that re drives PCI Express signals to an extension chassis via the ACL EXPRESS cable Users can plug EC 8560 into an ExpressCard...

Page 31: ...008 User s Manual 3 3 PXI 8565 Layout Connectors and Jumpers Figure 3 3 PCI 8565 Mechanical Layout Connector Jumper LED Description J1 Spread spectrum clock control CN1 PCI Express serial link connect...

Page 32: ...etting Description Enables spread spectrum control When enabling spread spectrum control the PCI clock will be modulated with a low frequency carrier the peak EMI can be greatly reduced in the system...

Page 33: ...es in length These cables are designed to transfer high speed signals and have high immunity from electromagnetic interference Figure 3 4 Standard 3 M extension cable ALC PCEEXT 3 Part Number Descript...

Page 34: ...20 Hardware Information EC 8560 PXI 8565 ADLINK Technology Inc User s Manual Copyright 2008 This page intentionally left blank...

Page 35: ...gth is 7 M ADLINK offers three different cables in length for customer s applications 1 M 3 M and 7 M Question When using ADLINK PCI Express Bus Extension Prod ucts is there any additional driver or s...

Page 36: ...each device according to its algorithm Although PCI speci fication allows up to 255 bus segments in a PC system the BIOS may not assign the correct and or proper resource to each device in some compl...

Page 37: ...ce functions of your host PC to release IO resources 2 Remove PCI devices plugged installed in your host PC 3 Connect an extension chassis which is single bus seg ment to the host PC Plug a PCI device...

Page 38: ...24 Troubleshooting FAQ EC 8560 PXI 8565 ADLINK Technology Inc User s Manual Copyright 2008 This page intentionally left blank...

Page 39: ...alling removing equipment Z Turn off power and unplug any power cords cables X To avoid electrical shock and or damage to equipment Z Keep equipment away from water or liquid sources Z Keep equipment...

Page 40: ...power X Equipment must be serviced by authorized technicians when Z The power cord or plug is damaged Z Liquid has penetrated the equipment Z It has been exposed to high humidity moisture Z It is not...

Page 41: ...s factory X Peripherals and third party products not manufactured by ADLINK will be covered by the original manufacturers war ranty X For products containing storage devices hard drives flash cards e...

Page 42: ...h humidity or volatile chemi cals X Damage caused by leakage of battery fluid during or after change of batteries by customer user X Damage from improper repair by unauthorized technicians X Products...

Reviews: