The DMI-1210 is a 12.1” Driver Machine Interface panel PC

designed specifically for the railway industry, equipped with Intel

Atom® x5-E3930 processor (formerly Apollo Lake), resistive

touch, and MVB interface. It can be applied as an HMI unit for

driver’s desks, control panel for passenger information systems,

surveillance system control/display unit or in railway diagnostics

and communications applications.

1.2

Features

X

Intel Atom® x5-E3930 processor, 1.8GHz

X

12.1” color display: 4:3, 1024x768 pixels, 600cd/m2,

X

5-wire resistive touch

X

Software controlled backlight

X

MVB/CAN bus support by PC/104 or Mini PCIe add-on 

modules

X

Built in GNSS and two Mini PCIe card slots for cellular 

modem with USIM

X

+24/+36/+72/+110 VDC nominal power input (EN50155 

compliant)

X

IP65 front and IP20 rear ingress ratings (IP42 rear available 

by request)

Summary of Contents for DMI-1210

Page 1: ...Leading EDGE COMPUTING Manual Rev 1 1 Revision Date February 21 2020 Part No 50 1Z284 1010 DMI 1210 Driver Machine Interface User s Manual...

Page 2: ...ii Revision History Leading EDGE COMPUTING Revision History Revision Release Date Description of Change s 1 0 2019 02 20 Initial release 1 1 2020 02 21 Correct USB 1 1 M8 Connector pinout...

Page 3: ...ges arising out of the use or inability to use the product or documentation even if advised of the possibility of such damages Environmental Responsibility ADLINK is committed to fulfill its social re...

Page 4: ...e harm For more information go to www P65Warnings ca gov TrademarksProduct names mentioned herein are used for identi fication purposes only and may be trademarks and or registered trademarks of their...

Page 5: ...3 Mechanical Layout 8 2 4 Mechanical Dimensions 11 2 5 Power Specifications 12 2 5 1 Power Consumption 12 2 5 2 System Power Features 13 3 Getting Started 15 3 1 Removing the Rear Cover 15 3 2 Install...

Page 6: ...3 Main Setup 59 6 3 1 BIOS Information 59 6 3 2 System Information 60 6 3 3 System Time System Date 60 6 3 4 Board Information 61 6 4 Advanced Menu 62 6 4 1 CPU Configuration 63 6 4 2 Graphic Configur...

Page 7: ...set Menu 75 6 5 1 North Bridge 75 6 5 2 South Bridge 75 6 5 3 Uncore Configuration 76 6 5 4 South Cluster Configuration 77 6 5 5 HD Audio Configuration 77 6 6 Security Menu 84 6 6 1 Secure Boot 86 6 7...

Page 8: ...viii Table of Contents Leading EDGE COMPUTING This page intentionally left blank...

Page 9: ...ront Layout 8 Figure 2 3 DMI 1210 Rear I O Layout 9 Figure 2 4 DMI 1210 Side I O Layout 10 Figure 2 5 DMI 1210 Bottom I O Layout 10 Figure 2 6 DMI 1210 Dimensions 11 Figure 3 1 DMI 1210 Mounting Hole...

Page 10: ...x List of Figures Leading EDGE COMPUTING This page intentionally left blank...

Page 11: ...t 46 Table 5 4 GbE1 GbE2 M12 Connector Pinout 47 Table 5 5 Audio M8 Connector Pinout 47 Table 5 6 MVB Bus Female DB9 Connector Pinout 48 Table 5 7 MVB Bus Male DB9 Connector Pinout 49 Table 5 8 CAN Bu...

Page 12: ...xii List of Tables Leading EDGE COMPUTING This page intentionally left blank...

Page 13: ...n systems surveillance system control display unit or in railway diagnostics and communications applications 1 2 Features X Intel Atom x5 E3930 processor 1 8GHz X 12 1 color display 4 3 1024x768 pixel...

Page 14: ...J45 Ethernet cable X 1x 4 pin M8 to Type A USB 1 1 cable X 1x 6 pin M8 to microphone and speaker cable X 2x 9 pin D sub male to female cables for MVB PC 104 MVB Kit P N 91 95239 200E X 1x PC 104 MVB c...

Page 15: ...P N 30 60099 0000 X 2x internal RF cables P N 30 60066 0000 Mini PCIe card Wi Fi BT Kit P N 91 95239 600E X 1x Mini PCIe GSM TD SCDMA CDMA WCDMA LTE mod ule AMPAK AP12356_I X 2x external antennas P N...

Page 16: ...4 Leading EDGE COMPUTING This page intentionally left blank...

Page 17: ...d teaming USB 1x USB 1 1 port via M8 connector with 2kV isolation 1x USB 3 0 Type A port with dust cover for maintenance Serial 2x RS232 422 485 serial ports via DB 9 Audio Mic in and Line out port vi...

Page 18: ...out 274 5 x 216 9 mm Environmental Operating Temperature 25 C to 70 C EN50155 T3 class Storage Temperature 40 C to 85 C Humidity 10 90 RH operating non condensing 5 95 RH storage EN 60068 2 30 EN 5015...

Page 19: ...SB 1 1 M8 Port x1 Mini PCIe Con x1 SIM Slot SIM Slot 32 func key box header 8x GPIO Wafer Backlight Volume key Wafer Power M12 Con 24 36V or 72 110VDC 40 input Light Sensor Cap Touch Panel Opt USB Cam...

Page 20: ...ut Front View The status LEDs are located on the right side of the bezel and the ambient brightness sensor at the top of the bezel as shown Figure 2 2 DMI 1210 Front Layout Power GbE Activity Serial P...

Page 21: ...connector A5 3G 4G Aux antenna SMA connector X1 X2 COM1 COM2 DB9 connectors X3 USB 1 1 M8 connector X4 X5 GbE1 GbE2 M12 connectors X6 Audio M8 connector X7 X8 MVB CAN bus DB9 connectors X9 DC power i...

Page 22: ...10 Leading EDGE COMPUTING Side View Figure 2 4 DMI 1210 Side I O Layout Bottom View Figure 2 5 DMI 1210 Bottom I O Layout USB2 CFast slot...

Page 23: ...ons Figure 2 6 DMI 1210 Dimensions Dimensions in mm 310 248 33 75 186 50 31 10 247 80 27 75 31 10 7 50 155 R5 4x M6 through hole 10 4x90 R2 87 30 27 90 101 10 1 224 286 310 RUBBER WIDTH 248 RUBBER WID...

Page 24: ...m temperature Input Voltage Loading Setup Voltage Current Power Cons 24VDC Stress 100 loading on CPU GPU RAM by running Intel TAT tool 24 1V 0 9A 22 0W 24VDC S3 mode 24 1V 0 28A 6 83W 24VDC S4 mode 24...

Page 25: ...will shut down and try to restart every 6 seconds until the over current con dition is corrected Input Over Temperature Protection Power will automatically shut down when the operating tempera ture o...

Page 26: ...14 Leading EDGE COMPUTING This page intentionally left blank...

Page 27: ...15 DMI 1210 3 Getting Started 3 1 Removing the Rear Cover To install the optional modules first remove the rear cover as described below 1 Remove the cover on the USB2 slot as shown USB Cover...

Page 28: ...ING 2 Remove all the screws indicated silver color NOTE NOTE Do NOT remove the black screws These are used to secure the heat spreaders inside the cover M3 Screws others are M2 5 screws Note Do NOT re...

Page 29: ...17 DMI 1210 3 Remove the rear cover It may be necessary to use a tool such as a flat head screwdriver to lift the cover away from the display frame Rear Cover...

Page 30: ...ng EDGE COMPUTING 3 2 Installing a PC 104 MVB Module optional Follow the instructions below to install a PC 104 MVB module 1 Remove the cover on the X7 and X8 D SUB port openings D SUB port cover M2 5...

Page 31: ...19 DMI 1210 2 Install the PC 104 MVB module with four M3 screws as shown MVB Module M3 Screws...

Page 32: ...two D SUB cables to the PC 104 MVB module and X7 X8 ports as shown Use the female to male cable for the X7 port and male to female cable for the X8 port Note that the 90 D SUB connectors go to the mod...

Page 33: ...21 DMI 1210 3 3 Installing Wi Fi and LTE Modules optional Follow the instructions below to install Mini PCIe Wi Fi and LTE modules 1 Remove the caps on the A2 A5 SMA connector openings Remove Caps...

Page 34: ...modules insert the SMA connectors into the openings and secure with washers and nuts as shown Route the cables as shown below CAUTION Make sure that the cables are clear of the CPU as this will affect...

Page 35: ...described in Step 2 on page 22 above for Mini PCIe LTE and Wi Fi modules 2 Connect the one end of the Y split cable to the module and the two D SUB connectors to the X7 and X8 ports using the nut scre...

Page 36: ...3 1 below M5 thread or 5 5 through hole 2 Attach I O cables to the device before installing into the panel if rear access will be limited after installation see Mechanical Layout on page 8 3 Place th...

Page 37: ...25 DMI 1210 Figure 3 2 Mounting the DMI 1210 M5xL40 Screw O Ring M5 Nut 5 5 through hole Platform DMI 1210 M5 Screw torque 10 0 Kgf cm for...

Page 38: ...E COMPUTING 3 6 CFast Card Installation To install or remove the CFast card remove the M2 5 screws securing the CFast slot cover and remove the cover Insert the CFast card and secure the cover CFast C...

Page 39: ...erminal X Slide the ring terminal onto the ground stud and secure it with the locking M4 nut as shown Connecting Peripherals Connect all the peripheral devices needed for your system to func tion CAUT...

Page 40: ...tem may only be carried out by personnel qualified for the specific task and who have the training and experience to identify risks and avoid potential hazards Z Make sure that a ground cable has been...

Page 41: ...he first boot device is the onboard eMMC To enter the BIOS setup menu to change the boot device order enter Del or Esc The DMI 1210 can be delivered with Linux Ubuntu 16 04 LTS or Windows 10 already i...

Page 42: ...hics win64_15 60 01 4877 exe 3 LAN LAN APPS SETUP SETUPBD Winx64 SetupBD exe 4 Audio Audio 0008 64bit_Win7_Win8_Win81_Win10 _R281 exe 5 PenMount Windows USB Driver PenMount Win dows USB Driver V2 4 5...

Page 43: ...31 DMI 1210 11 Wi Fi To install the Wi Fi driver do the following Open the Device Manager...

Page 44: ...32 Leading EDGE COMPUTING R click on Other Devices Network Controller and select Update Driver Software...

Page 45: ...33 DMI 1210 Select Browse my computer for driver softwaret...

Page 46: ...34 Leading EDGE COMPUTING Navigate to the path WiFi and BT module_BCM4356 WiFi x64 DHD_REL_1 558 53 33_Win10_x64 and click Next...

Page 47: ...35 DMI 1210 Select Install this driver software anyway and then click Close when the driver has finished installing...

Page 48: ...TING Navigate to the path WiFi and BT module_BCM4356 WiFi Right click on the file Install_nvram bat and click Yes in the User Account Control pop up This will copy the file 4356r2nvram txt into C Wind...

Page 49: ...37 DMI 1210 Open the Device Manager R click on Broadcom 802 11ac Wireless PCEI Full Dongle Adapter and disable it Click Yes when asked to confirm...

Page 50: ...38 Leading EDGE COMPUTING R click on Broadcom 802 11ac Wireless PCEI Full Dongle Adapter and enable it...

Page 51: ...39 DMI 1210 Wi Fi will now be functional...

Page 52: ...40 Leading EDGE COMPUTING 3 9 2 Linux Drivers To install the Linux drivers please download and follow the instructions in the DMI 1210 Linux Drivers Installation Guide...

Page 53: ...earch http www amtouch com tw downloads penmount drivers Uncompress the package and install it by doing the following Uncompress PenMount calibration tool tar jxvf pmLinux Ubuntu_12 04 18 04_32_64bit_...

Page 54: ...reen perform the following steps 1 Select Filter and search for Pen to find the PenMount Utility 2 Open the utility select the number of points you wish to calibrate and click on Calibrate to start 3...

Page 55: ...als_read c o als_read perform test application to read out Lux value als_read sample logs root adlink SP AL home adlink ALS als_read DBG seeking dev i2c 1 DBG write data 0x00 fail DBG read data failur...

Page 56: ...tness Set brightness to min echo 0 sys devices pci0000 00 0000 00 02 0 drm card0 card0 eDP 1 intel_backlight brightnes s Set brightness to max echo 96000 sys devices pci0000 00 0000 00 02 0 drm card0...

Page 57: ...locations Table 5 1 Status LED Definitions LED Function Power Status LED is on when DC Power is connected and system is powered on GbE1 2 Activity LED flashes when Ethernet port is active COM1 2 Tx R...

Page 58: ...cations COM1 X1 COM2 X2 DB9 Connectors Table 5 2 COM1 COM2 Serial Port Pinout USB 1 1 M8 Connector X3 Table 5 3 USB 1 1 M8 Connector Pinout Pin RS 232 RS 422 RS 485 Pin1 DCD TXD D Pin2 RXD TXD D Pin3...

Page 59: ...GbE1 GbE2 M12 Connector Pinout Audio M8 Connector X6 Table 5 5 Audio M8 Connector Pinout Pin Signal Name 1 MDO0P 2 MDO0N 3 MDO1P 4 MDO1N 5 MDO3P 6 MDO3N 7 MDO2N 8 MDO2P Pin Signal Name 1 MIC 2 GND 3 S...

Page 60: ...d MVB bus line with RS485 level 2 A data N Inverted MVB bus line with RS485 level 3 NC Not connected 4 B data P bidirectional Non inverted MVB bus line with RS485 level 5 B data N Inverted MVB bus lin...

Page 61: ...line with RS485 level 2 A data N Inverted MVB bus line with RS485 level 3 NC Not connected 4 B data P bidirectional Non inverted MVB bus line with RS485 level 5 B data N Inverted MVB bus line with RS...

Page 62: ...Bus Male DB9 Connector Pinout DC power input M12 connector X9 Table 5 9 DC Power Input Pinout Pin COM3 Function COM4 Function 1 NC NC 2 Port 0 CAN L Port 1 CAN L 3 NC NC 4 NC NC 5 NC NC 6 GND GND 7 Po...

Page 63: ...DMI 1210 USB2 Connector USB 3 0 Table 5 10 USB2 USB 3 0 Pinout Pin Signal Name 1 5V_USB3 2 USB2_P0_DN_CN 3 USB2_P0_DP_CN 4 GND 5 USB3_P0_RXN_CN 6 USB3_P0_RXP_CN 7 GND 8 USB3_P0_TXN_CN 9 USB3_P0_TXP_C...

Page 64: ...tion Pin Signal Name Ground S1 SATA_TX P S2 SATA_TX N S3 Ground S4 SATA_RX N S5 SATA_RX P S6 Ground S7 CFast_CDI P1 Ground P2 NC P3 NC P4 NC P5 NC P6 Ground P7 CFast_LED1 P8 CFast_LED2 P9 NC P10 NC P1...

Page 65: ...53 DMI 1210 Internal USB 2 0 Header CN16 Table 5 12 Internal USB 2 0 Header CN16 Pinout Figure 5 1 Internal USB 2 0 Header CN16 Location Pin Signal Name 1 5V 2 USB_D 3 USB_D 4 GND 5 NC 6 NC 1 CN16...

Page 66: ...54 Leading EDGE COMPUTING This page intentionally left blank...

Page 67: ...r menus Setup Menu The main BIOS setup menu is the first screen that you can navi gate Each main BIOS setup menu option is described in this user s guide The Main BIOS setup menu screen has two main f...

Page 68: ...tup utility uses a key based navigation system called hot keys Most of the BIOS setup utility hot keys can be used at any time during the setup navigation process NOTE NOTE There is a hot key legend l...

Page 69: ...reen Press the F1 key to open the General Help screen F2 The F2 key on your keyboard is the previous values key It is not displayed on the key legend by default To set the previous values settings of...

Page 70: ...ve made and exit Setup Press the F10 key to save your changes The following screen will appear Press the Enter key to save the configuration and exit You can also use the Arrow key to select Cancel an...

Page 71: ...as built MRC Version Info only w x y z Display the revision of MRC code which is implemented in BIOS GOP Version Info only x y zzzz VBIOS Version When video option ROM is set to Legacy Only this will...

Page 72: ...ting the system CPU Frequency Info only XXXX MHz Display CPU frequency Total Memory Info only XXXX MB DDRx Display total memory size used on the motherboard and memory type Memory Frequency Info only...

Page 73: ...in minutes the system is running in S0 state Current Runtime Info only The returned value specifies the time in seconds the system is running in S0 state This counter is cleared when the system is rem...

Page 74: ...features functions Graphic Configuration Submenu For setting graphic controller parameters Power Management Submenu System Management Submenu Thermal Management Submenu Watchdog Timer Submenu Super IO...

Page 75: ...ed C status Disable Enable Enables disables C1E where when enabled CPU will switch to minimum speed when all cores enter CStates Max Package C Status PC2 PC1 C0 Sets the Max Package C State supported...

Page 76: ...ual LVDS bus Set single dual LVDS bus mode DE Polarity Active High Active Low Configure DE Polarity Vsync Polarity Active High Active Low Configure Vsync Polarity Hsync Polarity Active High Active Low...

Page 77: ...es or disables lock of legacy resource mPCIe Slot Wake Disabled Enabled Enables disables PCI Express slot wake capability FM Board Wake Disabled Enabled Enables disables FM Board wake capability RTC W...

Page 78: ...re was built SEMA Bootloader Read only Show SEMA bootloader s version Build Date Read only Show when SEMA bootloader was built SEMA Features Submenu Flags Submenu BIOS Item Options Description SEMA Su...

Page 79: ...If this item is shown it means SEMA supports System Fan 1 DTS register Info only If this item is shown it means SEMA supports DTS register DTS offset registers Info only If this item is shown it means...

Page 80: ...ensor Startup Read only Show the board temperature at system power up Min Read only Show the minimum board temperature after system boot Max Read only Show the maximum board temperature after system b...

Page 81: ...mount of time after power up Pressing F12 key during startup will disable the power up watchdog timer RunTime Watchdog Enabled Disabled Enables disables RunTime watchdog which when enabled resets the...

Page 82: ...0 11 12 IO 2F8 IRQ 3 4 5 7 9 10 11 12 IO 3E8 IRQ 3 4 5 7 9 10 11 12 IO 2E8 IRQ 3 4 5 7 9 10 11 12 Select an optimal setting for Super IO device Serial Port x Control RS232 RS422 RS485 Select serial po...

Page 83: ...be matched on the other side Long or noisy lines may require lower speed Data Bits 7 8 Configure the number of data bits in each transmitted or received serial character for both serial ports Parity...

Page 84: ...XON XOFF VT UTF8 Combo Key Support Disabled Enabled Enable VT UTF8 combination key support for ANSI VT100 terminals Recorder Mode Disabled Enabled With this mode enabled only text will be sent This is...

Page 85: ...Enabled Enables disables BIOS support for security device When enabled OS will not show the security device and TCG EFI protocol and INT1A interface will not be available BIOS Item Options Descriptio...

Page 86: ...the delay is taken from the Hub descriptor BIOS Item Options Description NIC Configuration Submenu For configuring link speed and wake function Blink LEDs Value Range Identifies the physical network p...

Page 87: ...ons Description Memory Information Info only Total Memory Info only Display Total Memory Size Memory Voltage Info only Display Memory Voltage Memory Slot0 Info only Display Installed Memory Slot0 Info...

Page 88: ...ce IGD when selected as the Primary Video Adaptor Disable Always disable IGD Primary Display IGD PCIe HG Select which of IGD PCI Graphics device should be Primary Display Aperture Size 128MB 256MB 512...

Page 89: ...A Drives Submenu SCC Configuration Submenu USB Configuration Submenu Miscellaneous Configuration Submenu BIOS Item Options Description HD Audio Support Disabled Enabled Enables disables HDA Audio Audi...

Page 90: ...y for the most optimum power savings Enable Enable PCIe root port Disable Disable PCIe root port BIOS Item Options Description PCI Express Root Port X Disable Enable Auto Control the PCI Express Root...

Page 91: ...Express System Error on Correctable Error Enable Disable PME SCI Disable Enable PCI Express PME SCI Enable Disable Hot Plug Disable Enable PCI Express Hot Plug Enable Disable PCIe Speed Auto Gen1 Gen2...

Page 92: ...ult Maintain default BIOS flow PCIE LTR Lock Disable Enable PCIE LTR Configuration Lock PCIe Selection De emphasis Disable Enable When the Link is operating at 5 0 GT s speed this bit selects the leve...

Page 93: ...If enabled for any of ports Staggered Spin Up will be performed and only the drives which have this option enabled will spin up at boot Otherwise all drives spin up at boot SATA Device Type Hard Disk...

Page 94: ...nabled will spin up at boot Otherwise all drives spin up at boot SATA Device Type Hard Disk Drive Solid State Drive Identify the SATA port is connected to Solid State Drive or Hard Disk Drive SATA Por...

Page 95: ...DCI Support Disabled Enabled Enables disables XDCI support XHCI Disable Compliance Mode Disabled Enabled Selects XHCI Disable Compliance Mode USB HW Mode AFE Comparators Disabled Enabled Enables disab...

Page 96: ...password is installed the HDD master password is can not be changed BIOS Item Options Description Administrator Password Enter to set password Configure Clear Administrator Password When pressing ent...

Page 97: ...fied only when successfully unlocked with Master Password in POST HDD PASSWORD CONFIGURATION Security Supported Yes Security Enabled Yes Security Locked No Security Frozen No Select Screen HDD User Pw...

Page 98: ...re Boot BIOS Item Options Description System Mode Info only Secure Boot Info only Secure Boot Control Disabled Enabled Secure Boot can be enabled if 1 System running in User mode with enrolled Platfor...

Page 99: ...ect the keyboard NumLock state after system boot Quiet Boot Disabled Enabled Enabled will show splash screen during POST Disabled will show boot message during POST Fast Boot Disabled Enabled Enable o...

Page 100: ...et system do reset to boot system Discard Changes and Reset Enter Discard all changed settings and let system do reset to boot system Save Changes Enter Save all changed settings Discard Changes Enter...

Page 101: ...urn off power and unplug any power cords cables X To avoid electrical shock and or damage to equipment Z Keep equipment away from water or liquid sources Z Keep equipment away from high heat or high h...

Page 102: ...ed by authorized technicians when Z The power cord or plug is damaged Z Liquid has penetrated the equipment Z It has been exposed to high humidity moisture Z It is not functioning or does not function...

Page 103: ...08 360 0200 Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China...

Reviews: