ADLINK Technology cPCIS-6130R Series User Manual Download Page 5

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for cPCIS-6130R Series

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...orld Manual Rev 2 01 Revision Date December 26 2006 Part No 50 15011 100 cPCIS 6130R Series 1U Height Subsystem for 6U CompactPCI User s Manual Artisan Technology Group Quality Instrumentation Guarant...

Page 3: ...ty to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copy right All rights are reserved No part of this...

Page 4: ...2 82265717 Address 9F No 166 Jian Yi Road Chungho City Taipei 235 Taiwan Please email or FAX this completed service form for prompt and satisfactory service Company Information Company Organization Co...

Page 5: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 6: ...tPCI Card Installation 5 2 3 Rear Transition Module Installation Removal 7 2 4 Powering Up the System 8 3 Backplanes 9 3 1 Features 9 3 2 Specifications 9 3 3 Mechanical Drawing 10 3 4 Connector and J...

Page 7: ...C4 APS 115XU 26 Features 26 Specifications 27 Output Characteristics 27 Mechanical Drawing 27 Important Safety Instructions 29 Warranty Policy 31 Artisan Technology Group Quality Instrumentation Guara...

Page 8: ...3 Figure 2 1 Installing a 6U SBC module 6 Figure 2 2 Latching the cPCI module handles securely 7 Figure 2 3 cPCIS 6130R Series switches and LED 8 Figure 3 1 cBP 6105R Backplane Front View 10 Figure 3...

Page 9: ...iv Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 10: ...a removable air filter pro vides for convenient maintenance 1 1 Features General X 19 rackmount 1U height chassis provides 2 slots for 6U cPCI cards with 80mm RTMs for front and rear I O access X PIC...

Page 11: ...al plate outer covering Guarded power switch and reset button Cooling System Two intake fans with removable air filter four exhaust fans see Chapter 4 Cooling for details Power Supply 200W 1U AC ATX P...

Page 12: ...ayout Figure 1 1 cPCIS 6130R Front View Figure 1 2 cPCIS 6130R Rear View Figure 1 3 cPCIS 6130R Left View Figure 1 4 cPCIS 6130R Right View Artisan Technology Group Quality Instrumentation Guaranteed...

Page 13: ...Subsystems can be customized to meet the specific needs of your application To customize a subsystem please contact an ADLINK dealer or visit the Where to Buy page of our website for more information...

Page 14: ...es power cords replacement air filter ergonomic rackmount handles and pouch containing screws zip ties etc X This User s Manual 2 2 CompactPCI Card Installation CompactPCI connectors are rigid and the...

Page 15: ...ts otherwise the EMC and cooling performance will be compromised 2 Hold the SBC module or peripheral card horizontally Make sure that the handles are unlatched i e that they are spread outwards If nec...

Page 16: ...undo the retaining screws press the red release buttons and reverse steps 1 through 5 above 2 3 Rear Transition Module Installation Removal The installation and removal procedures for a Rear Transitio...

Page 17: ...ower switch and reset button that provide ATX power control capability Use the tool provided in the Accessory Packet or a suitably shaped object such as a pen to actuate the power switch and reset but...

Page 18: ...cations X CompactPCI Compliancy Z PICMG 2 0 CompactPCI core specification R3 0 Z PICMG 2 1 CompactPCI hot swap R2 0 X Dimension 321 5 x 39 64 mm W x H X PCI bus clock 64 bit 66MHz X System slot rear I...

Page 19: ...kplanes 3 3 Mechanical Drawing Figure 3 1 cBP 6105R Backplane Front View Figure 3 2 cBP 6105R Backplane Rear View Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisant...

Page 20: ...orted jumpers must be set in pairs Power LED J2 Speaker J3 Pin Signal 1 NC 2 12V 3 GND Pin Signal Pin Signal 1 5V 2 5V 3 V I O 4 V I O 5 3 3V 6 3 3V Pin Signal 1 5V 2 GND Pin Signal 1 5V 2 NC 3 NC 4 B...

Page 21: ...nal 1 3 3V 11 3 3V 2 3 3V 12 12V 3 GND 13 GND 4 5V 14 PS_ON_L 5 GND 15 GND 6 5V 16 GND 7 GND 17 GND 8 PWRGOOD 18 5V 9 STB5V 19 5V 10 12V 20 5V Pin Signal 1 Power On 2 GND 3 5VSb Pin Signal 1 RESET 2 G...

Page 22: ...GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY BDSEL TRDY GND 12 14 Keying Area 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 GND AD 23 GND AD...

Page 23: ...38 GND V I O AD 37 AD 36 GND 12 GND AD 42 AD 41 AD 40 GND AD 39 GND 11 GND AD 45 GND V I O AD 44 AD 43 GND 10 GND AD 49 AD 48 AD 47 GND AD 46 GND 9 GND AD 52 GND V I O AD 51 AD 50 GND 8 GND AD 56 AD...

Page 24: ...NC NC NC NC GND 12 GND NC NC NC NC NC GND 11 GND NC NC NC NC NC GND 10 GND NC NC NC NC NC GND 9 GND NC NC NC NC NC GND 8 GND NC NC NC NC NC GND 7 GND NC NC NC NC NC GND 6 GND NC NC NC NC NC GND 5 GND...

Page 25: ...GND NC NC NC NC NC GND 16 GND NC NC NC NC NC GND 15 GND NC NC NC NC NC GND 12 14 Keying Area 11 GND NC NC NC NC NC GND 10 GND NC NC NC NC NC GND 9 GND NC NC NC NC NC GND 8 GND NC NC NC NC NC GND 7 GND...

Page 26: ...C GND 14 GND NC NC NC NC NC GND 13 GND NC NC NC NC NC GND 12 GND NC NC NC NC NC GND 11 GND NC NC NC NC NC GND 10 GND NC NC NC NC NC GND 9 GND NC NC NC NC NC GND 8 GND NC NC NC NC NC GND 7 GND NC NC NC...

Page 27: ...GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY BDSEL TRDY GND 12 14 Keying Area 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 IDSEL AD 23 GND A...

Page 28: ...38 GND V I O AD 37 AD 36 GND 12 GND AD 42 AD 41 AD 40 GND AD 39 GND 11 GND AD 45 GND V I O AD 44 AD 43 GND 10 GND AD 49 AD 48 AD 47 GND AD 46 GND 9 GND AD 52 GND V I O AD 51 AD 50 GND 8 GND AD 56 AD 5...

Page 29: ...NC NC NC NC NC GND 12 GND NC NC NC NC NC GND 11 GND NC NC NC NC NC GND 10 GND NC NC NC NC NC GND 9 GND NC NC NC NC NC GND 8 GND NC NC NC NC NC GND 7 GND NC NC NC NC NC GND 6 GND NC NC NC NC NC GND 5 G...

Page 30: ...17 GND NC NC NC NC NC GND 16 GND NC NC NC NC NC GND 15 GND NC NC NC NC NC GND 12 14 Keying Area 11 GND NC NC NC NC NC GND 10 GND NC NC NC NC NC GND 9 GND NC NC NC NC NC GND 8 GND NC NC NC NC NC GND 7...

Page 31: ...NC NC GND 14 GND NC NC NC NC NC GND 13 GND NC NC NC NC NC GND 12 GND NC NC NC NC NC GND 11 GND NC NC NC NC NC GND 10 GND NC NC NC NC NC GND 9 GND NC NC NC NC NC GND 8 GND NC NC NC NC NC GND 7 GND NC N...

Page 32: ...sure proper performance of the system the air filter should be cleaned or replaced as necessary A replacement air filter is supplied and can be found in the Accessory Packet Air Filter Removal and Rep...

Page 33: ...brushless Z Rated voltage 12V Z Rated Current 0 13 A Z Rated Power 1 6 W Z Fan speed 8200RPM Z Max air flow 10 8 CFM Z Acoustical Noise 27 5 dBA each NMB 1606KL 04W B50 left side exhaust fans x3 Z Di...

Page 34: ...1950 CSA 22 2 NO 950 TUV IEC 950 X Cooling TWO 40 mm NMB ball bearing DC Fans Specifications X Output Watts 200W X Dimensions 190x100x40 mm X AC Input Voltage 90 264 VAC Full Range X MTBF 84 228 Hour...

Page 35: ...ting 0 50 X Humidity Operating 20 95 Non operating 10 95 X Remarks 85 is normal condition and 95 is with special coating process X EMI noise filter FCC CLASS A CISPR22 CLASS A X Safety UL 1950 CSA 22...

Page 36: ...V maynotexceed100watts 2 Total output power may not exceed 200 watts Mechanical Drawing Output Voltage Output Current A Regulation Load Regulation Line Output Ripple Noise Max P P MIN MAX 5V 2 18 5 1...

Page 37: ...28 Power Supply Unit Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 38: ...switch is set to the proper position for the area The voltage selector switch is set at the factory to the cor rect voltage X For pluggable equipment ensure they are installed near a socket outlet tha...

Page 39: ...replaced by an incorrect type Dispose used batteries as instructed in the instructions X The equipment should be checked by service personnel if one of the following situation arises Z The power cord...

Page 40: ...l be covered by the original manufactur ers warranty X For products containing storage devices hard drives flash cards etc please back up your data before send ing them for repair ADLINK is not respon...

Page 41: ...eries by customer user X Damage from improper repair by unauthorized ADLINK technicians X Products with altered and or damaged serial numbers are not entitled to our service X This warranty is not tra...

Page 42: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Reviews: