Power Supply Unit
65
5.4 Output Characteristics
Properties
1: OVP built-in
2: Adjustable
3: Remote sensing
4: 3rd-wire Load Sharing
5: Droop Current Sharing
6: Installed with Or-ing diode
7: Magnetic Amplifier
8: Installed with Post-regulator
9: Common Choke
Remarks
Peak load sustainable for less than 60sec. with duty cycle
<10%. Max. load is the continuous operating load of each
rail. Max. load of each rail cannot be drawn from all outputs
at the same time.
X
Over Load Protection: Fully protected against output over-
load or short circuit. Typical 120% max. load.
X
Over Current Protection: Installed at each rail
X
Output Wattage: Typ. 250W continuous.
X
Output Connector: Positronic 47-pin PCIH47M400A1.
X
Line Regulation: Typ. 0.1%.
X
Load Regulation: Typ. ±1–2%.
Output Voltage
(see below for properties)
Output Current (A)
MIN.
MAX.
TYP.
PEAK.
5V
MAIN +VO1
(1, 2, 3, 4, 6)
2.0
33.0
25.0 –
3.3V
AUX. +VO2
(1, 2, 3, 4, 6, 7)
0
33.0
18.0
–
12V
AUX. +VO3
(1, 2, 3, 4, 6, 7)
0
5.5
5.5
6.0
-12V
AUX. –VO4
(1, 5, 6, 8, 9)
0
1
0.5
1.5