background image

22

Board Interfaces

4.4

Connector Pin Assignments

See “Board Layout - Front” on page 19 for connector locations.

Front Panel Connectors

Gigabit Ethernet Connectors (CN13/CN14, RJ-45)

Pin #

GbE Signal

1

2

LAN_TX0-

3

4

5

LAN_TX2-

6

LAN_TX1-

7

8

Status

Speed LED

(Green/Amber)

Activity LED

(Amber)

Network link is not established 

or system powered off

OFF

OFF

10 Mbps 

Link

OFF

ON

Active

OFF

Blinking

100 Mbps 

Link

Green

ON

Active

Green

Blinking

1000 Mbps 

Link

Amber

ON

Active

Amber

Blinking

8

1

Speed

Activity

Summary of Contents for cPCI-6525

Page 1: ...Advance Technologies Automate the World Manual Rev 0 10 preliminary Revision Date April 17 2015 Part No 50 15101 1010 cPCI 6525 6U CompactPCI 3rd Generation Intel Core i7 Processor Blade User s Manual...

Page 2: ...Revision History Revision Release Date Description of Change s 0 10 2015 04 17 Preliminary release...

Page 3: ...en if advised of the possibility of such damages Environmental Responsibility ADLINK is committed to fulfill its social responsibility to global environmental preservation through compliance with the...

Page 4: ...OTE NOTE Additional information aids and tips that help users perform tasks CAUTION Information to prevent minor physical injury component dam age data loss and or program corruption when trying to co...

Page 5: ...5 Package Contents 6 2 Specifications 7 2 1 cPCI 6525 Blade Specifications 7 2 2 I O Connectivity 9 2 3 Power Requirements 10 3 Functional Description 13 3 1 Processors 13 3 2 Chipset 15 3 3 Intel Tu...

Page 6: ...l 21 4 4 Connector Pin Assignments 22 4 5 Buttons Switches and Jumpers 33 5 Checkpoints Beep Codes 37 5 1 Checkpoint Ranges 37 5 2 Standard Checkpoints 37 5 3 OEM Reserved Checkpoint Ranges 46 Importa...

Page 7: ...Figures vii cPCI 6525 List of Figures Figure 1 1 cPCI 6525 Functional Block Diagram 4 Figure 4 1 cPCI 6525 Board Layout Front 19 Figure 4 2 cPCI 6525 Board Layout Back 20 Figure 4 3 cPCI 6525 Front P...

Page 8: ...viii List of Figures This page intentionally left blank...

Page 9: ...List of Tables ix cPCI 6525 List of Tables Table 2 1 cPCI 6525 Blade Specifications 7 Table 2 2 cPCI 6525 I O Connectivity 9 Table 4 1 DVI I Connector Pin Definition 24...

Page 10: ...x List of Tables This page intentionally left blank...

Page 11: ...Gen2 convertible to two PCIe x8 Gen2 and one PCIe x4 to rear IO Additional IO functionality of the cPCI 6525 includes three USB 3 0 ports and one RS 232 422 485 serial port via RJ 45 connector on the...

Page 12: ...he Intelligent Platform Management Interface IPMI as well as hardware monitoring of physical char acteristics such as CPU and system temperature DC voltages and power status The cPCI 6525 is ideal for...

Page 13: ...n peripheral slots X Three USB 3 0 ports from PCH X SATA 6 Gb s direct connector for onboard 2 5 drive X CFast slot via adapter board X 8x general purpose user programmable LEDs on front panel default...

Page 14: ...COM6 COM1 SPI DDR3 1333 1600 FDI DVI GbE1 GbE2 DVI I USB1 USB2 USB3 COM1 Soldered ECC max 8GB ECC SO CDIMM max 8GB PCIe x1 BIOS Intel 82574IT PCI 64b 66M USB 3 0 SATA0 GbE3 GbE4 Intel 82574IT Intel 8...

Page 15: ...X cPCI R66S0 6U 8HP width RTM with DVI D 1x COM 3x USB 4x GbE 4x eSAS SATA 4x iSAS SATA PS 2 KB MS and Line in out X cPCI R66N0 6U 8HP width RTM with DVI I DVI D 1x COM and 1x USB 2x GbE RJ 45 onboar...

Page 16: ...n the board X RJ 45 to DB 9 cable for RJ 45 COM port X 2 5 SATA drive mounting kit including bracket and screws for 2 5 SATA drive and DB LSATA adapter card X CFast socket kit including DB CFAST adapt...

Page 17: ...el BD82QM77 Platform Controller Hub PCH Memory Dual channel DDR3 1066 1333 1600 SDRAM with ECC total up to 16GB One channel in SODIMM sockets up to 8GB One channel soldered onboard up to 8GB dependent...

Page 18: ...rd drive removable 1 One SATA 6 Gb s CFast slot by adapter board Three SATA 3Gb s to rear IO Faceplate I O 2x 10 100 1000BASE T Ethernet ports 1x DVI I RGB switchable to rear 3x USB 3 0 ports 1x RJ 45...

Page 19: ...rced air flow is required see 2 4 Thermal Requirements Tempera ture limit of optional mass storage devices may affect the ther mal specification 2 2 I O Connectivity Table 2 2 cPCI 6525 I O Connectivi...

Page 20: ...le to provide at least three times as much power as the entire system requires of each voltage The tolerance of the voltage lines described in the CompactPCI specification PICMG 2 0 R3 0 is 5 3 for 5...

Page 21: ...ge was measured by run ning Intel Thermal Analysis Tool 4 3 Quad Core Intel Core i7 3615QE 2 3GHz TDP 45W Quad Core Intel Core i7 3612QE 2 1GHz TDP 35W OS Mode 5V Current A 3 3V Current A 12V Current...

Page 22: ...12 Specifications This page intentionally left blank...

Page 23: ...erformance lower cost easier valida tion and improved x y footprint The processor includes an inte grated display engine processor graphics integrated memory controller and integrated I O on a single...

Page 24: ...WiFi Technology X Enhanced Intel SpeedStep Technology X Thermal Monitoring Technologies X Intel Fast Memory Access X Execute Disable Bit X Intel VT x with Extended Page Tables EPT Interfaces X Dual c...

Page 25: ...o ports X Supports USB 2 0 USB 3 0 X USB host interface with two EHCI high speed USB 2 0 Host controllers and two rate matching hubs provide support for up to fourteen USB 2 0 ports X Integrated 10 10...

Page 26: ...power load the number of active cores user configurable settings operating environment and system design If the power current or thermal limit is reached the processor will automatically reduce the fr...

Page 27: ...ty If the voltage fluctuates dramatically this function can block the data transfer and lock the chip X Low High frequency sensor to detect the IC clock fre quency If the frequency fluctuates dramatic...

Page 28: ...18 Functional Description This page intentionally left blank...

Page 29: ...85 SW10 System reset CN6 10 15 USB 3 0 ports SW12 Serial port mode select CN9 SATA drive connector SW_COMDEG1 Reserved for debug CN13 CN14 GbE ports SW_IPMCDEG1 Reserved for debug CN21 DVI connector S...

Page 30: ...20 Board Interfaces 4 2 Board Layout Back Figure 4 2 cPCI 6525 Board Layout Back SW8 RGB to front rear switch SW11 GbE to front rear switch SW_11 SW_8...

Page 31: ...D Color Condition Indication Power Green OFF System is off ON System is on Blink Fail to power on payload power failure HotSwap Blue OFF Handles closed System is on Fast Blink Preparing to shut down s...

Page 32: ...N14 RJ 45 Pin GbE Signal 1 LAN_TX0 2 LAN_TX0 3 LAN_TX1 4 LAN_TX2 5 LAN_TX2 6 LAN_TX1 7 LAN_TX3 8 LAN_TX3 Status Speed LED Green Amber Activity LED Amber Network link is not established or system power...

Page 33: ...RJ 45 COM1 RJ 45 to DB 9 Cable Pin RS 232 RS 422 RS 485 1 DCD TX Data 2 RTS 3 DSR 4 TXD RX 5 RXD TX Data 6 GND 7 CTS 8 DTR L RX Pin RS 232 RS 422 RS 485 1 DCD TX Data 2 RXD TX Data 3 TXD RX 4 DTR L R...

Page 34: ...TX_P Pin Signal Pin Signal 1 TMDS Data2 16 Hot Plug Detect 2 TMDS Data2 17 TMDS Data0 3 GND 18 TMDSData0 4 NC 19 GND 5 NC 20 NC 6 DDC Clock SCL 21 NC 7 DDC Data SDA 22 GND 8 Analog vertical sync 23 TM...

Page 35: ...5 Onboard Connectors SATA Connector on DB LSATA Pin Signal S1 GND S2 TX S3 TX S4 GND S5 RX S6 RX S7 GND P1 NC P2 NC P3 NC P4 GND P5 GND P6 GND P7 5V P8 5V P9 5V P10 GND P11 Reserved P12 GND P13 P15 12...

Page 36: ...ame Ground S1 SATA_TX P S2 SATA_TX N S3 Ground S4 SATA_RX N S5 SATA_RX P S6 Ground S7 CFast_CDI P1 Ground P2 NC P3 NC P4 NC P5 NC P6 Ground P7 CFast_LED1 P8 CFast_LED2 P9 NC P10 NC P11 NC P12 P3V3 P13...

Page 37: ...14 GND GND 15 16 GND GND 17 18 GND GND 19 20 GND GND 21 22 GND GND 23 24 GND GND 25 26 GND GND 27 28 GND GND 29 30 GND P3V3 31 32 P5V P3V3 33 34 P5V P3V3 35 36 P5V P3V3 37 38 P5V NC 39 40 P12V CFAST_...

Page 38: ...GND 16 GND CPCI_DEVSEL L GND VIO CPCI_STOP L CPCI_LOCK L GND 15 GND P3V3 CPCI_FRAME L CPCI_IRDY L NC CPCI_TRDY L GND 12 14 GND Key Area Key 11 GND CPCI_AD18 CPCI_AD17 CPCI_AD16 GND CPCI_CBE L2 GND 10...

Page 39: ...NC GND FAL REQ5 GNT5 GND 14 GND AD35 AD34 AD33 GND AD32 GND 13 GND AD38 GND V I O AD37 AD36 GND 12 GND AD42 AD41 AD40 GND AD39 GND 11 GND AD45 GND V I O AD44 AD43 GND 10 GND AD49 AD48 AD47 GND AD46 GN...

Page 40: ...USB9 N GND 12 GND USB6 P USB6 N GND USB7 P USB7 N GND 11 GND USB4P USB4 N GND USB5 P USB5 N GND 10 GND USB OC45 RGB DDCCLK RGB DDCDAT RGB HSYNC RGB VSYNC GND 9 GND COM2 CTS COM2 RI RGB BLUE RGB RED R...

Page 41: ...8 GND PCIE_R XN8 GND PCIE_RXP11 GND 16 GND PCIE_TXN8 PCIE_TXP9 GND PCIE_RXP9 PCIE_RXN11 GND 15 GND GND PCIE_TXN9 GND PCIE_CPU _RXN9 GND GND 12 14 GND Key Area Key 11 GND SMB_CLK_PCH PCIE_CPU _TXP7 GND...

Page 42: ...TMDSD_DATA TMDSD_DATA0 GND SATA TX2 SATA TX2 GND 13 GND LAN3_LED_100L LAN4_LED_100 L NC LAN4_LED__1G L LAN3_LED_1G L GND 12 GND DVI_DATA DVI_CLK DVI_HTPLG BLUELED_CN WDTLED L GND 11 GND TMDSB_DATA2 TM...

Page 43: ...ations System Reset Button The cPCI 6525 has a system reset button on the front panel See cPCI 6525 Front Panel on page 21 for the button location Load BIOS Default Button SW1 Press switch SW1 to load...

Page 44: ...RS 422 ON ON RS 485 OFF ON Pin Status Description 1 OFF Reserved 2 OFF When the system does not include a Chassis Management Module CMM set this pin to OFF to allow IPMI to run in without CMM mode def...

Page 45: ...SW8 GbE to Front Rear Switch SW11 Pin Status Description 1 OFF RGB to front default ON RGB to rear 2 OFF Normal default ON Debug Pin Status Description 1 OFF GbE1 to rear ON GbE1 to front default 2 O...

Page 46: ...heir settings should not be altered unless instructed by ADLINK The default settings are as follows SW_COMDEG1 1 2 ON 3 4 OFF SW_IPMCDEG1 All OFF SW_COMPW1 ON short 2 3 BIOS Write Protection Jumper CN...

Page 47: ...up to BDS 0x90 0xCF BDS execution 0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Status Code Description 0x00 Not use...

Page 48: ...Codes 0x10 PEI Core is started 0x11 Pre memory CPU initialization is started 0x12 Pre memory CPU initialization CPU module specific 0x13 Pre memory CPU initialization CPU module specific 0x14 Pre memo...

Page 49: ...emory initialization other 0x30 Reserved for ASL see ASL Status Codes section below 0x31 Memory Installed 0x32 CPU post memory initialization is started 0x33 CPU post memory initialization Cache initi...

Page 50: ...nitialization error SPD reading has failed 0x52 Memory initialization error Invalid memory size or memory modules do not match 0x53 Memory initialization error No usable memory detected 0x54 Unspecifi...

Page 51: ...ecovery Progress Codes 0xF0 Recovery condition triggered by firmware Auto recovery 0xF1 Recovery condition triggered by user Forced recovery 0xF2 Recovery process started 0xF3 Recovery firmware image...

Page 52: ...e Services 0x63 CPU DXE initialization is started 0x64 CPU DXE initialization CPU module specific 0x65 CPU DXE initialization CPU module specific 0x66 CPU DXE initialization CPU module specific 0x67 C...

Page 53: ...0x77 South Bridge DXE Initialization South Bridge module specific 0x78 ACPI module initialization 0x79 CSM initialization 0x7A 0x7F Reserved for future AMI DXE codes 0x80 0x8F OEM DXE initialization...

Page 54: ...ction below 0xAD Ready To Boot event 0xAE Legacy Boot event 0xAF Exit Boot Services event 0xB0 Runtime Set Virtual Address MAP Begin 0xB1 Runtime Set Virtual Address MAP End 0xB2 Legacy Option ROM Ini...

Page 55: ...d password 0xD9 Error loading Boot Option LoadImage returned error 0xDA Boot Option is failed StartImage returned error 0xDB Flash update is failed 0xDC Reset protocol is not available of Beeps Descri...

Page 56: ...he S2 sleep state 0x30 System is waking up from the S3 sleep state 0x40 System is waking up from the S4 sleep state 0xAC System has transitioned into ACPI mode Interrupt controller is in PIC mode 0xAA...

Page 57: ...urn off power and unplug any power cords cables X To avoid electrical shock and or damage to equipment Z Keep equipment away from water or liquid sources Z Keep equipment away from high heat or high h...

Page 58: ...iced by authorized technicians when Z The power cord or plug is damaged Z Liquid has penetrated the equipment Z It has been exposed to high humidity moisture Z It is not functioning or does not functi...

Page 59: ...300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China Tel 86 21 5132 8988 Fax 86 21 5132 3588 Email market adlinktech com ADLINK Technology Beijing Address 1 E 801 100085 Rm 8...

Page 60: ...5 Fax 82 2 2057 0563 Email korea adlinktech com ADLINK Technology Singapore Pte Ltd Address 84 Genting Lane 07 02A Cityneon Design Centre Singapore 349584 Tel 65 6844 2261 Fax 65 6844 2263 Email singa...

Reviews: