2 . GENERAL INFORMATION  

 

2.1 INTRODUCTION   

- This welding machine is a power source for MMA welding and scratch strike TIG welding, made specifically for direct 

current (DC). 

The specific characteristics of this regulation system (INVERTER), i.e. high speed and precise regulation, mean the 

welding machine gives excellent results when welding with coated electrodes (rutile, acid, basic). 
Regulation with the “inverter” system at the input of the power supply line (primary) means there is a drastic reduction 

in the volume of both the transformer and the levelling reactance. This allows the construction of a welding machine 

with extremely reduced weight and volume, enhancing its advantages of easy handling and transportation.  

 

2.2 OPTIONAL ACCESSORIES: 

- MMA welding Kit.  

 

3. TECHNICAL DATA 

 

DATA PLATE  

 The most important data regarding use and performance of the welding machine are summarized on the rating plate 

and have the following meaning:  

  1 

– Protection class 

  2 

– Symbol of the power supply line 

  3 

– Type of the welding process  

  4 

– Construction diagram  

  5 

– Safety norm  

  6 

– Serial number 

  7 

– Parameters of the welding circuit 

  8 

– Power supply line specifications  

  9 - Size of delayed action fuses to be used to protect the power line 

10 

– Symbols referring to safety regulations 

   

 

The data plate shown below is an example to give the meaning of the symbols and numbers; the exact values of 

technical data for the welding machine in your possession must be checked directly on 

the data plate of the welding machine itself. 

 

 

 

 

 

 

 

10 

Summary of Contents for MMA-200

Page 1: ......

Page 2: ...ower Consumption 8 3 kW 9 5 kW Welding Current Range 20 200A 20 200A Diameter of Electrodes 2 4 2 5 Automatic Circuit Breaker 16A 20A No load Current Voltage 62 V 62 V Efficiency 80 80 Isolation Class F F Protection Class IP21 IP21 Weight 7 kg 7 kg Dimensions 390x125x240mm 390x125x250mm ...

Page 3: ...lsory Wearing of Protective Gloves is Compulsory Users of vital electrical and electronic apparatus must never use the machine Non Ionizing Radiation separation of electrical and electronic appliances for refuse collection The user is not allowed to dispose of these appliances as solid mixed urban refuse and must do it through authorized refuse collection centers ...

Page 4: ...tection outlet Do not use the welding machine in damp or wet places and do not weld in the rain Do not use cables with worn insulation or loose connections Always wear dry protection gloves and clothes Never touch electric parts with bare hands Make sure your position when welding is safe and comfortable Make sure you are properly isolated from the floor and from the working place Poisonous fumes ...

Page 5: ...DING OPERATIONS in environments with increased risk of electric shock in confined spaces in the presence of flammable or explosive materials MUST BE evaluated in advance by an expert supervisor and must always be carried out in the presence of other people trained to intervene in emergencies The operator MUST NOT BE ALLOWED to weld in raised positions unless safety platforms are used VOLTAGE BETWE...

Page 6: ...hancing its advantages of easy handling and transportation 2 2 OPTIONAL ACCESSORIES MMA welding Kit 3 TECHNICAL DATA DATA PLATE The most important data regarding use and performance of the welding machine are summarized on the rating plate and have the following meaning 1 Protection class 2 Symbol of the power supply line 3 Type of the welding process 4 Construction diagram 5 Safety norm 6 Serial ...

Page 7: ...re and simultaneously isolates the welding circuit from the mains 4 Secondary rectifier bridge with inductance this changes the alternate voltage current supplied by the secondary windings into continuous current voltage at a low wave length 5 Electronic and regulation board this instantly checks the value of the welding current against that selected by the user it modulates the commands of the IG...

Page 8: ...l 5 3 POSITION OF THE WELDING MACHINE Choose the place to install the welding machine so that the cooling air inlets and outlets are not obstructed forced circulation by fan if present at the same time make sure that conductive dusts corrosive vapors humidity etc will not be sucked into the machine Leave at least 250mm free space around the welding machine WARNING Position the welding machine on a...

Page 9: ...return cable of the welding current this could jeopardize safety and result in poor welding 5 5 2 TIG WELDING WITH SCRATCH STRIKE Connect TIG torch to the negative socket with the quick connector Turn the welding cable connectors right down into the quick connections Connect the clamp to the positive socket Turn the welding cable connectors right down into the quick connections Argon tank connecti...

Page 10: ...essary to use the exact electrode diameter with the exact current see the table 6 2 1 Procedures Holding the mask IN FRONT OF THE FACE strike the electrode tip on the workpiece as if you were striking a match To stop welding lift the electrode over welded object 7 MAINTENANCE WARNING BEFORE CARRYING OUT MAINTENANCE OPERATIONS MAKE SURE THE WELDING MACHINE IS SWITCHED OFF AND DISCONNECTED FROM THE ...

Page 11: ...plugs outlets fuses etc Check that the yellow led i e thermal protection interruption either over or undervoltage or short circuit is not lit Check that the nominal intermittence ratio is correct In case there is a thermal protection interruption wait for the machine to cool down check if the fan is working properly Check the mains voltage if the value is too high or too low the welding machine wi...

Reviews: