Adler ADCHARGER 5.3 Instruction Manual Download Page 4

 

the true input voltage to the battery and adjust the output voltage of the unit accordingly. 
This will maximize the charging efficiency. 

 
Reverse-polarity Protection 

This unit offers reverse-polarity protection, the RED “REVERSE” LED will illuminate and the 
charging process will not start. If this happens, unplug immediately from the mains, connect 
the red crocodile clip to positive (+) battery post, and black crocodile clip to negative (-) post, 
then plug into the mains power and the charging process will start. 

 
Short-circuit Protection 

Should you accidentally touch the crocodile clips together whilst the mains power is on, the 
unit will not perform charging. Unplug from the mains, disconnect and start the process again 
being careful not to touch the clips together. 
 

Cable Connector 

The charger has two options for connecting the 
unit to the battery. Via the intelligent cable 
connector, you can select witch connection you 
want to use: 

 

Crocodile clamps for easy and flexible use. 

 

O-ring connectors for permanent fixation on your battery.  

 
Other Features 

Anti Spark Protection 
Battery and Charger Overheating Protection 
Waterproof ABS Housing. Ingress Protection Rating IP65. 
 
 

OPERATION 

PLEASE READ CAREFULLY BEFORE USING 

 
Suitable for 6 & 12V Normal Lead Acid, Sealed, Leisure or Gel Batteries between           
10-70Ah. 
 
1. Preparing the Battery 

Firstly remove the caps from each cell and check that the level of the liquid is sufficient in 
each cell. If it is below the recommended level, top up with de-ionized or distilled water. 

 

Note: 

Under no circumstances should tap water be used. 

The cell caps should not be replaced until charging is complete. This allows any gases formed 
during charging to escape. It is inevitable that some minor escape of acid will occur during 
charging. 

For permanently sealed battery, it is not necessary to carry out the above checks. 

 

2. Connection 

Connect the positive charging lead (red) to the positive terminal post of the battery (marked  
P or +). Connect the negative charging lead (black) to the negative terminal post of the 
battery (marked N or -). It is important to ensure that both DC clamps are making good 
contact with their respective terminal posts. 
Connect the charger’s AC power cable to an AC power outlet. Once you have connected the 
DFC530N battery charger to AC power, it will sound a tone for 0,5 seconds and the Simple 
Touch power panel LEDs light for two seconds. 
 

3. Reverse Polarity 

If the DC battery clamps are connected improperly to the battery terminals, the reverse 
polarity LED will light up. The battery charger’s warning buzzer will also sound. If this occurs 
simply disconnect the battery charger from the AC power. Connect the DC clamps correctly to 
the battery terminals. Reconnect the charger to the AC power. 