User manual arsos®  dexos® light wds · Version 1.1 JS

3

Dear client!
You are now holding the user manual of the

arsos® filius

therapeutic support

system of

ADL® GmbH

in your hands.

arsos® filius

is a mattress replacement system, divided into three segments, with

28 (20) independent removable air foam cells.
This air foam technology enables the mattress by means of air support to adjust
itself to the weight and convenience of the patient.
The functions are based upon known mechanisms. The system is equipped with
a soft foam mattress with reinforced edges. Further

arsos® filius

is a dynamic

or - when needed - static air filled mattress with an 11,5 cm safety foam layer
which prevents the patient to sink to the bed base level in case of a system
disorder.

When changing treatment of the patient, the foam mattress can be converted
into a dynamic system through connecting the mattress to different control power
units (e.g.

dexos® light wds or dexos® autoplus

).

The composition of the system can be considered a system in a system making
adaptations possible to suit a wide variety of diseases.
This module concept also combines more advantages concerning the safety aspects
as the protection of the bed side rails when large cell systems are being used.
Higher bed side rails, which head-contain again safety problems by falling heights,
do not become any longer necessarily, as the employment of the

arsos® filius

mattress, offer appropriate defaults that are kept in accordance with DIN EN
1970-2000 and DIN EN 60601-2-38.

With the writing of this user manual the product management of the

ADL® GmbH

has set itself the goal, to create a good and understandable aid and guidance for
the employment of the system. If nevertheless questions remain, please ask your
provider for direction and assistance.

Your

Foreword

GmbH

Summary of Contents for arsos 111 510-DL-wds

Page 1: ...r Manual arsos filius dexos light wds Item No 111 510 DL wds Ulcer Pressure Relief System Assembly and Operation instructions Health Security Independence Mattress arsos filius Power unit dexos light...

Page 2: ...page 5 4 Explanation of indications and functions page 5 5 Installation arsos filius page 6 6 Installation dexos light wds page 6 7 Other settings page 10 8 Auxiliary functions page 10 9 Cleaning ins...

Page 3: ...ttress can be converted into a dynamic system through connecting the mattress to different control power units e g dexos light wds or dexos autoplus The composition of the system can be considered a s...

Page 4: ...XPLOSION DANGER Warning Note The compressor is under power as soon as the power supply plug is put in Before opening the housing of the compressor the power plug is to be unplugged Repairs must be per...

Page 5: ...results in an as large as possible surface and maximum pressure relaxation The reinforcements of the foam edges are an advantage for the sense of feeling and the mobility of the patient Touching the...

Page 6: ...tely The dual stretch and breathing cover is to be fixed to the bed base with the zipper on both sides Before putting the patient on the mattress you can fill air into the system with a hand pump As t...

Page 7: ...um and maximum level The unit starts up in alternating mode with a 5 minute cycle The red alarm light 5 is flashing and the system will start to be filled with air The red alarm light is put out of ci...

Page 8: ...button 2 lower When pressure is too low hammock effect press button 2 higher Please note that status of the air cells is to be checked daily and whenever required adjustment is needed Each time when...

Page 9: ...xtended pressure in the sacral area Optimal support of the patient Knee joints lumbar and cranial lordosis are supported Principle of alternating pressure every second cells pair deflated showing grou...

Page 10: ...change from green to blue alternate In alternate mode 2 out of 3 cells are filled with air to the set pressure level One cell remains without pressure Don t forget to increase the pressure when switch...

Page 11: ...ry function The unit has a memory function This means when the power is interrupted the unit will remember the set values up to about 24 hours Thus after transfer of a patient connecting to the power...

Page 12: ...mperature of 75 C should be kept In case of an arsos filius Mattress with an alternating power unit this should be cleaned with an damp cloth and soap detergent or a mild non aldehyds cleaning deterge...

Page 13: ...operate Power supply plug plug and partition blue lamp at defect power cord socket Check the the switch is not defect safety fuse safety fuse illuminated defect Red alarm light Defect air cell Check...

Page 14: ...cording to Braden according to EPUAP Patients with Patients with 10 kg 50 body weight and 50 kg body weight Static Pressure ulcers prevention and Instable fractures soft bedding therapy support up los...

Page 15: ...shable adequate detergents dryer can be used to 50 C Warranty only valid in case of production or material failures 12 Technical data 13 air foam combinations Item No Description dexos light dexos aut...

Page 16: ...s Phone 31 0 13 5772 088 Fax 31 0 13 5772 648 E mail info adlmedical nl Internet www adlmedical nl ADL GmbH Lise Meitner Stra e 3 48161 Muenster Germany Phone 49 0 2534 6224 0 Fax 49 0 2534 64270 ADL...

Reviews: