background image

ADJ Products, LLC  -  www.adj.com  - XS 200 User Manual Page 7

female XLR connector on either end of the cable. Also remember that 

DMX cable must be daisy chained and cannot be split.

 XS 200                                                              DMX Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 O T

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 O T

3-PIN XLR

Figure 4

ADJ Products, LLC  -  www.adj.com  - XS 200 User Manual Page 6

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Pin 5 - Do Not Use

Pin 4 - Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

 XS 200                                                              DMX Set Up

 XS 200                                                            CAD Drawing

284.5

86

74.4

145

65

123.6

100

Summary of Contents for XS 200

Page 1: ...s and product names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of...

Page 2: ...ease do not return this unit to your dealer without contacting customer sup port first Introduction The ADJ XS 200 is a new revolution in moving lights It features a single Axis head that has continuous 360 degree tilt rotation The XS 200 can operate as a stand alone fixture or in a Master Slave configuration The XS 200 has three operating modes sound active mode show mode and DMX control This fix...

Page 3: ...Page 4 ADJ Products LLC www adj com XS 200 User Manual Page 5 Power Supply The ADJ XS 200 contains a automatic voltage switch which will auto sense the voltage when it is plugged into the power source With this switch there is no need to worry about the correct power voltage this unit can be plugged in anywhere DMX 512 DMX is short for Digital Multiplex This is a universal pro tocol used by most l...

Page 4: ...nator on the last unit to avoid erratic behavior A terminator is a 110 120 ohm 1 4 watt resistor which is con nected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line Using a cable terminator ADJ part number Z DMX T will decrease the possibilities of erratic behavior DMX512 IN 3 PI...

Page 5: ...er slave configuration 1 Press the MENU button until STAL is displayed press ENTER Either MAST or SLAv will be displayed 2 Press the UP or DOWN buttons until your desired setting is dis played press ENTER to confim SHND Show modes 0 8 Factory programs 1 Press the MENU button until SHND is displayed press ENTER 2 Sh X will now be displayed X representing a number between 0 8 Shows 1 8 are preset sh...

Page 6: ...e the UP or DOWN buttons to choose an operating mode you would like the unit XS 200 System Menu ADJ Products LLC www adj com XS 200 User Manual Page 10 to start up in when power is applied or the DMX signal is lost HOLD If the DMX signal is lost the fixture will stay in the last DMX setting If power is applied and this mode is set the unit will automati cally go into the last DMX set up SHOU Show ...

Page 7: ...ired function you would like to test press ENTER 3 After you have pressed ENTER use the UP and DOWN but tons to adjust the values and test the function To exit press the MENU button HRS With this function you can display the running time of the unit 1 Press the MENU button until HRS is displayed press ENTER 2 The running time of the fixture will now be displayed Press MENU to exit XS 200 System Me...

Page 8: ...played and then press ENTER Use the UP or DOWN buttons to adjust the sound sensitivity 1 being the least sensitive and 100 being the most sensitive Show Mode In this mode you can choose 1 of 8 show modes to run 1 Press the MENU button until SHND is displayed and press ENTER 2 Press the UP or DOWN buttons until you find your desired show XS 200 Operation XS 200 Operation and press ENTER then press ...

Page 9: ...irst time strobe at the highest rate Press the button a second time to strobe at medium rate Press the button a third time to strobe at the slowest rate Press the button for a fourth time to exit COLOR Press this button and use buttons 1 9 to select your desired color See the color chart below for the numeral buttons and colors 1 9 When in color or show mode these buttons will allow you to select ...

Page 10: ...20 STANDARD 21 40 STAGE 41 60 TV 61 80 ARCHITECTURAL 81 100 THEATRE 101 255 DEFAULT DIMMER SETTING XS 200 18 Channel Mode Channel Value Function 1 0 255 PAN 2 0 255 PAN FINE 3 0 255 TILT 4 0 255 TILT FINE 5 TILT CONTINUOUS ROTATION 0 55 NO FUNCTION 56 127 CLOCKWISE ROTATION 128 199 COUNTER CLOCKWISE ROTATION 200 255 NO FUNCTION 6 PAN CONTINUOUS ROTATION SPEED 0 255 SLOW FAST 7 0 255 RED LED 0 100 ...

Page 11: ...RAM 2 66 90 PROGRAM 3 91 115 PROGRAM 4 116 140 PROGRAM 5 141 165 PROGRAM 6 166 190 PROGRAM 7 191 215 PROGRAM 8 216 240 RANDOM PROGRAM PLAYING 5 TIMES EACH 241 255 RANDOM PROGRAM 2 MINS EACH 15 0 255 PROGRAM SPEED SLOW FAST 16 0 255 PAN TILT SPEED FAST SLOW 17 SPECIAL FUNCTIONS 0 69 NO FUNCTION 70 79 BLACKOUT WITH PAN TILT MOVEMENT 80 89 NO FUNCTION 90 99 BLACKOUT WITH RGBW VALUE CHANGE 100 199 NO ...

Page 12: ...whatsoever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or removed if the product is modified in any manner which ADJ Products LLC concludes after inspection affects the reliability of the product if the product has been repaired or serviced by anyone other than the ADJ Products LLC factory unless prior ...

Page 13: ...ADJ Products LLC www adj com XS 200 User Manual Page 24 ADJ Products LLC www adj com XS 200 User Manual Page 25 XS 200 Notes XS 200 Notes ...

Page 14: ... Weight 4 Lbs 2 kgs Colors RGBW Color Mixing Fuse 1A Duty Cycle None DMX Modes 2 DMX Channel Modes 16 Channel Mode 18 DMX Channels Working Position Any Safe Secure Position Warranty 2 Year 730 days Auto Sensing Voltage This fixture contains a automatic volt age switch which will auto sense the voltage when it is plugged into the power source ADJ Products LLC 6122 S Eastern Ave Los Angeles CA 90040...

Reviews: