ADJ Products, LLC • Los Angeles, Ca USA • Kerkrade, Netherlands
8
MAINTENANCE GUIDELINES
Careful and regular maintenance is necessary to optimize the potential functional lifespan of the VS3IP
LED Video Panels.
1.
Read the installation and operation instructions for correct operation of the VS3IP LED Video
Panels.
2.
Although the VS3IP LED Video Panels are designed and built to withstand some impact forces
when installed correctly, take care to avoid impact damage when handling or transporting them,
especially corners and edges which are particularly frangible during transportation.
3.
The fixture should be serviced by a qualified service technician when:
A.
Objects have fallen, or liquid has been spilled into the fixture.
B.
The fixture has been exposed to rain or water conditions in excess of IP rating parameters
(IP65 front / IP54 rear)
.
C.
The fixture does not appear to operate normally or exhibits a marked change in performance.
D.
The fixture has fallen and/or subjected to extreme handling.
4.
Check each VS3IP LED Video Panel for loose screws and other fasteners.
5.
If the VS3IP LED Video Panel installation is fixed or displayed for a lengthy time, regularly inspect
all rigging and installation equipment, and replace or repair it as necessary, and d
uring long periods
of non-use, disconnect the main power to the unit.
6.
Use necessary ESD (electrostatic discharge) precautions when handling VS3IP LED Video Panels,
especially the LED screens, as they are ESD sensitive and easily damaged from ESD exposure.
7.
The Null Line and Live Line connections from the computer and control system cannot be reversed,
and should therefore only be connected in original layout order.
8.
If the GFI (Ground Fault Interrupt) breaker-switch trips often, check the display or replace the
power-supply switch.
9.
When operating the VS3IP LED Video Panels, power the computer before powering the LED Video
Screens; conversely, when shutting down after operation, turn the LED Video Panels off before
turning off the computer. If the PC is turned off first, a high intensity brightness might appear,
causing catastrophic failure to those LEDs.
10.
If while conducting an electrical test a circuit shorts, a breaker-switch trips, wires burn, and or any
other abnormality appears, discontinue testing and troubleshoot units to find the problem before
continuing with any testing or operation.
11.
To ensure consistent operation, it might be necessary to learn operating parameters for installation,
data recovery, backup, controller settings, and basic data preset modification.
12.
Regularly check computer for any viruses, and remove any irrelevant data.
13.
Only a qualified technician should operate software system.
14.
Remove any moisture found inside or outside of any VS3IP LED Video Panels before dismantling
video installation, and returning them to their optional flight cases (sold separately). Ensure flight
cases are free of any moisture, using a fan to dry them if necessary, and avoid ESD generating
friction when returning VS3IP LED Video Panels.
15.
Although the VS3IP LED Video Panels are designed for indoor and outdoor usage within its IP
rating parameters (IP65 front / IP54 rear), limit or remove any unit exposure to moisture,
condensation, or humidity, and consider using air conditioning where available.
16.
When not in use, store VS3IP LED Video Panels in a dry, well ventilated facility.
Summary of Contents for VS3IP