ADJ QUAD SCAN PRO User Instructions Download Page 12

ADJ Products, LLC  -  www.adj.com  - Quad Scan Pro Instruction Manual Page 22

  Quad Scan Pro    

 

                             Cleaning

  Quad Scan Pro    

 

                Trouble Shooting

Trouble Shooting: Listed below are a few common problems that 

you may encounter, with solutions.
No light output from the unit;
1.   Be sure the external fuse has not blown. The fuse is located on  

   the rear panel of the unit. 

2.   Be sure the fuse holder is completely and properly seated. 

 

Unit does not respond to sound;
1.     Low frequencies (bass) should cause the unit to react to sound.

    Tapping on the microphone, quiet or high pitched sounds may

   not activate the unit.  

Fixture  Cleaning:

  Due  to  fog residue,  smoke,  and  dust  cleaning 

the internal and external optical lenses and mirror should be carried 

out periodically to optimize light output. Cleaning frequency depends 

on  the  environment  in  which  the  fixture  operates  (I.e.  smoke,  fog 

residue, dust, dew). In heavy club use we recommend cleaning on a 

monthly basis. Periodic cleaning will ensure longevity, and crisp out-

put.
1.  Use normal glass cleaner and a soft cloth to wipe down the out- 

  side casing.

2.   Use a brush to wipe down the cooling vents and fan grill.

3.   Clean the external optics and mirror with glass cleaner and a soft  

  cloth every 20 days.

4.   Clean the internal optics with glass cleaner and a soft cloth every  

  30-60 days.

5.  Always be sure to dry all parts completely before plugging the unit  

  back in.

  Quad Scan Pro 

                                           Fuse Replacement

Disconnect the unit from its power source. Remove the power cord 

from  the  unit.  Once  the  cord  has  been  removed,  you  will  find  that 

the fuse holder is located inside the power socket. Insert a flat-head 

screw driver into the power socket and gently pry out the fuse holder. 

Remove the bad fuse and replace with a new one. The fuse holder also 

has a holder for a spare fuse.

ADJ Products, LLC  -  www.adj.com  - Quad Scan Pro Instruction Manual Page 23

  Quad Scan Pro 

                                          Gobo Replacement

The Quad Scan Pro comes with 4 replaceable gobos. This gobos can 

be interchanged at any time and allows you to customize your sys-

tem. 
To replace gobo;

1. Select the gobo you would like to replace and unscrew the thumb  

    screw that is holding the gobo housing in place. Note: The thumb  

    screw cannot be removed.

2. Remove the gobo housing.

3. Once the gobo housing has been removed, remove the retaining

    ring that holds the gobo in. This can easily be done using needle  

    nose pliers.

4. Remove and replace the gobo with your desired replacement.       

    Reinsert the retainer ring, and make sure the ring rests firmly    

    against the gobo.

5. Slide the gobo houseing back into place, and secure the housing  

    by tighting the thumb screw. 

With  this  feature  you  can  connect  the  fixtures  to  one  another 

using the IEC input and output sockets. The quantity that can be 

connected is 4 fixtures maximum. After 4 fixtures you will need 

to use a new power outlet. They must be the same fixtures. DO 

NOT mix fixtures.

 Quad Scan Pro   

 

     Power Cord Daisy Chain

Summary of Contents for QUAD SCAN PRO

Page 1: ...uct names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building a...

Page 2: ...e keep this manual with the unit for future reference Quad Scan Pro General Instructions Quad Scan Pro General Information Unpacking Thank you for purchasing the Quad Scan Pro by ADJ Products LLC Ever...

Page 3: ...Heat This fixture should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce heat The fixture should be serviced by qualifi...

Page 4: ...ins a automatic volt age switch which will auto sense the voltage when it is plugged into the power source With this switch there is no need to worry about the correct power voltage this unit can be p...

Page 5: ...3 pin DMX line When inserting stan dard 5 pin data cables in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The chart below details a proper...

Page 6: ...will be displayed Choose an operating mode you would like the unit to start up in when power is applied or the DMX signal is lost MASL Master Slave If the DMX signal is lost or power is applied the un...

Page 7: ...er sion select NO and press Enter TILT Tilt Inversion 1 Tap the MENU button until TILT is displayed press ENTER Either YES or NO will be displayed 2 To activate the Tilt inversion tap the UP or DOWN b...

Page 8: ...n doing this the fixtures will now have contrast movement to each other Universal DMX Control This function allows you to use a univer sal DMX 512 controller to control the chases and patterns dimmer...

Page 9: ...N TILT MOVEMENTS 0 7 NO MOVEMENT 8 22 MOVEMENT 1 23 37 MOVEMENT 2 38 52 MOVEMENT 3 53 67 MOVEMENT 4 68 82 MOVEMENT 5 83 97 MOVEMENT 6 98 112 MOVEMENT 7 113 127 MOVEMENT 8 128 142 MOVEMENT 9 143 157 MO...

Page 10: ...R 2 0 255 0 100 15 MASTER DIMMER MIRROR 2 0 255 0 100 Quad Scan Pro 5 Channel Mode DMX Traits Channel Value Function 5 STATIC COLOR SEQUENCE 0 7 COLOR SEQUENCE 1 8 15 COLOR SEQUENCE 2 16 23 COLOR SEQU...

Page 11: ...100 22 WHITE MIRROR 3 0 255 0 100 23 MASTER DIMMER MIRROR 3 0 255 0 100 24 STROBING MIRROR 3 0 8 OPEN 9 131 STROBING SLOW FAST 132 139 OPEN 140 181 FAST CLOSE SLOW OPEN 182 189 OPEN 190 231 SLOW CLOS...

Page 12: ...plugging the unit back in Quad Scan Pro Fuse Replacement Disconnect the unit from its power source Remove the power cord from the unit Once the cord has been removed you will find that the fuse holde...

Page 13: ...ll expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the...

Page 14: ...5 kgs Fuse 7 Amp Duty Cycle None DMX 1 5 32 DMX Channel Modes Sound Active Yes Working Position Any Safe Secure Position Warranty 2 Year 730 days Auto Sensing Voltage This fixture contains a automati...