ADJ MEGA PAR PROFILE PLUS User Instructions Download Page 3

  Mega Par Profile Plus                           Safety Precautions

Power Supply:

 The ADJ Mega Par Profile Plus contains a automatic 

voltage switch, which will auto sense the voltage when it is plugged 

into the power source. With this switch there is no need to worry about 

the correct power voltage, this unit can be plugged in anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Mega Par Profile Plus can be controlled via DMX-512 protocol. The 

Mega Par Profile Plus has 5 DMX modes, please see pages 9-10 for 

the different modes. The DMX address is set on the back panel of the 

Mega  Par  Profile  Plus.  Your  unit  and  your  DMX 

controller require a standard 3-pin XLR connec-

tor for data input and data output (Figure 1). We 

recommend Accu-Cable DMX cables. If you are 

making your own cables, be sure to use standard 

110-120 Ohm shielded cable (This cable may be 

purchased at almost all pro lighting stores). Your 

cables should be made with a male and female 

XLR connector on either end of the cable. Also 

remember that DMX cable must be daisy chained 

and cannot be split.

ADJ Products, LLC  -  www.adj.com  - Mega Par Profile Plus User Manual Page 4

  Mega Par Profile Plus                                      DMX Set Up

ADJ Products, LLC  -  www.adj.com  - Mega Par Profile Plus User Manual Page 5

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids into or on to your unit.

•   Do not attempt to operate this unit if the power cord has been   

   frayed or broken. Do not attempt to remove or break off the ground 

   prong from the electrical cord. This prong is used to reduce the risk  

   of electrical shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Never plug this unit in to a dimmer pack

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out`  

   doors voids all warranties.

•   During long periods of non-use, disconnect the unit’s main power.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to the point they exit from the unit. 

• Cleaning -The fixture should be cleaned only as recommended by  

  t he manufacturer. See page 24 for cleaning details.

•   Heat -The appliance should be situated away from heat sources  

   such as radiators, heat registers, stoves, or other appliances (inclu-

   d ing amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. The power-supply cord or the plug has been damaged.

    B. Objects have fallen, or liquid has been spilled into the appliance.

    C. The appliance has been exposed to rain or water.

    D. The appliance does not appear to operate normally or exhibits a  

        marked change in performance.

Figure 1

Summary of Contents for MEGA PAR PROFILE PLUS

Page 1: ...brands and product names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equi...

Page 2: ...le Plus Installation Mega Par Profile Plus Introduction Unpacking Thank you for purchasing the Mega Par Profile Plus by ADJ Products LLC Every Mega Par Profile Plus has been thoroughly tested and has...

Page 3: ...o lighting stores Your cables should be made with a male and female XLR connector on either end of the cable Also remember that DMX cable must be daisy chained and cannot be split ADJ Products LLC www...

Page 4: ...n nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behavior...

Page 5: ...oducts LLC www adj com Mega Par Profile Plus User Manual Page 8 Mega Par Profile Plus Operating Instructions RGB UV Dimmer Mode 1 Plug the fixture in and press the MODE button until 2 When r XXX is di...

Page 6: ...button so that nodn is displayed Use the UP and DOWN buttons to scroll through the DMX states bLAC Blackout If the DMX signal is lost or interrupted the unit will automatically go into stand by mode L...

Page 7: ...DMX address ing DMX Channel mode DMX last state setting and dimming curves Some fixtures will come with different DMX channel modes When your desired menu submenu is found use the buttons to scroll th...

Page 8: ...ing the or buttons to scroll through the DMX Channel Modes Set the mode before you address the fixture See the bottom of this page for the DMX modes 2 After you have selected your mode set the DMX add...

Page 9: ...STROBING SLOW FAST 96 127 LED ON 128 159 STROBE PULSE SLOW FAST 160 191 LED ON 192 223 RANDOM STROBE SLOW FAST 224 255 LED ON 6 MASTER DIMMER 0 255 0 100 Mega Par Profile Plus 6 Channel Mode Mega Par...

Page 10: ...OLOR FADE 8 128 143 COLOR FADE 9 144 159 COLOR FADE 10 160 175 COLOR FADE 11 176 191 COLOR FADE 12 192 207 COLOR FADE 13 208 223 COLOR FADE 14 224 239 COLOR FADE 15 240 255 COLOR FADE 16 Mega Par Prof...

Page 11: ...VE MODE 2 32 47 SOUND ACTIVE MODE 3 48 63 SOUND ACTIVE MODE 4 64 79 SOUND ACTIVE MODE 5 80 95 SOUND ACTIVE MODE 6 96 111 SOUND ACTIVE MODE 7 112 127 SOUND ACTIVE MODE 8 128 143 SOUND ACTIVE MODE 9 144...

Page 12: ...T SENSITIVE 10 DIMMER CURVES 0 20 STANDARD 21 40 STAGE 41 60 TV 61 80 ARCHITECTURAL 81 100 THEATRE 101 255 DEFAULT TO UNIT SETTING Mega Par Profile Plus 10 Channel Mode Channel Value Function 8 COLOR...

Page 13: ...2 119 130 199 0 Color11 41 44 255 97 77 74 Color44 173 176 147 164 212 0 Color12 45 48 255 71 77 71 Color45 177 180 88 2 163 0 Color13 49 52 255 83 134 83 Color46 181 184 0 38 86 0 Color14 53 56 255 9...

Page 14: ...ADJ Products LLC in connection with this product including warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed o...

Page 15: ...ADJ Products LLC www adj com Mega Par Profile Plus User Manual Page 28 ADJ Products LLC www adj com Mega Par Profile Plus User Manual Page 29 Mega Par Profile Plus Notes Mega Par Profile Plus Notes...

Page 16: ...10 Channel Mode Warranty 2 Year 730 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice Auto Sensing Volt...

Reviews: