  Mega 64 HEX Pak                                  Safety Precautions

ADJ Products, LLC  -  www.adj.com  - Mega 64 HEX Pak User Manual Page 4

P

ower Supply:

 The ADJ Mega 64 HEX contains a automatic voltage 

switch, which will auto sense the voltage when it is plugged into the 

power source. With this switch there is no need to worry about the cor-

rect power voltage, this unit can be plugged in anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Mega 64 HEX Pak can be controlled via DMX-512 protocol. The 

Mega 64 HEX Pak has 5 DMX channel modes. The DMX address is set 

on the back panel of the Mega 64 HEX Pak. Your unit and your DMX con-

troller require a standard 3-pin XLR connector for data input and data 

output  (Figure  1).  We  recommend  Accu-Cable 

DMX cables. If you are making your own cables, 

be sure to use standard 110-120 Ohm shielded 

cable (This cable may be purchased at almost all 

pro lighting stores). Your cables should be made 

with a male and female XLR connector on either 

end of the cable. Also remember that DMX cable 

must be daisy chained and cannot be split.

ADJ Products, LLC  -  www.adj.com  - Mega 64 HEX Pak User Manual Page 5

  Mega 64 HEX Pak                                             DMX Set Up

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids into or on to your unit.

•   Do not attempt to operate this unit if the power cord has been   

   frayed or broken. Do not attempt to remove or break off the ground 

   prong from the electrical cord. This prong is used to reduce the risk  

   of electrical shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Never plug this unit in to a dimmer pack

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out`  

   doors voids all warranties.

•   During long periods of non-use, disconnect the unit’s main power.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to the point they exit from the unit. 

• Cleaning -The fixture should be cleaned only as recommended by  

  t he manufacturer. See page 25 for cleaning details.

•   Heat -The appliance should be situated away from heat sources  

   such as radiators, heat registers, stoves, or other appliances (inclu-

   d ing amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. The power-supply cord or the plug has been damaged.

    B. Objects have fallen, or liquid has been spilled into the appliance.

    C. The appliance has been exposed to rain or water.

    D. The appliance does not appear to operate normally or exhibits a  

        marked change in performance.

Figure 1

Summary of Contents for MEGA 64 HEX PAK

Page 1: ...names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building and...

Page 2: ...anual Page 2 Unpacking Thank you for purchasing the Mega 64 HEX Pak by ADJ Products LLC Every Mega 64 HEX Pak has been thoroughly tested and has been shipped in perfect operating condition Carefully c...

Page 3: ...able may be purchased at almost all pro lighting stores Your cables should be made with a male and female XLR connector on either end of the cable Also remember that DMX cable must be daisy chained an...

Page 4: ...n making your own cables Do not use the ground lug on the XLR connector Do not con nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s o...

Page 5: ...7 When u XXX is displayed you are in UV dimming mode Press the UP and DOWN buttons to adjust intensity ADJ Products LLC www adj com Mega 64 HEX Pak User Manual Page 9 Mega 64 HEX Pak Operating Instru...

Page 6: ...like the unit to return to when power is applied 1 Plug the fixture in and press the MODE button until d XXX is dis played XXX represents the current displayed DMX address 2 Press the SET UP button so...

Page 7: ...ash you are in 6 DMX Channel mode If the Green LED s flash you are in 7 DMX Channel mode If the Blue LED s flash you are in 8 DMX Channel mode If the White LED s flash you are in 11 DMX Channel mode I...

Page 8: ...100 Mega 64 HEX Pak 7 Channel Mode Mega 64 HEX Pak ADJ LED RC4 Operation Note When setting the DMX address each time a number is pressed a LED color will flash when you have set the DMX address corre...

Page 9: ...11 Channel Mode Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 WHITE 0 255 0 100 5 AMBER 0 255 0 100 6 UV 0 255 0 100 7 MASTER DIMMER 0 255 0 100 8 STROBING 0 255 S...

Page 10: ...UND ACTIVE MODE 5 80 95 SOUND ACTIVE MODE 6 96 111 SOUND ACTIVE MODE 7 112 127 SOUND ACTIVE MODE 8 128 143 SOUND ACTIVE MODE 9 144 159 SOUND ACTIVE MODE 10 160 175 SOUND ACTIVE MODE 11 176 191 SOUND A...

Page 11: ...7 COLOR CHANGE 3 48 63 COLOR CHANGE 4 64 79 COLOR CHANGE 5 80 95 COLOR CHANGE 6 Mega 64 HEX Pak 12 Channel Mode Channel Value Function 10 COLOR CHANGE PROGRAMS 96 111 COLOR CHANGE 7 112 127 COLOR CHAN...

Page 12: ...B W A UV Mega 64 HEX Pak 12 Channel Mode When Channel 9 is between the values of 0 51 Channels 1 6 are used and Channel 8 will control strobing When Channel 9 is between the values of 52 102 Channel...

Page 13: ...ugging the unit back in Cleaning frequency depends on the environment in which the fixture operates i e smoke fog residue dust dew Disconnect the unit from its power source Remove the power cord from...

Page 14: ...uct has been repaired or serviced by anyone other than the ADJ Products LLC factory unless prior written authorization was issued to purchaser by ADJ Products LLC if the product is damaged because not...