ADJ FOCUS SPOT 7Z User Manual Download Page 1

FOCUS SPOT 7Z

User Guide

Summary of Contents for FOCUS SPOT 7Z

Page 1: ...FOCUS SPOT 7Z User Guide ...

Page 2: ...or property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product ADJ USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 2650 323 532 2...

Page 3: ...r Flags Color Wheel Animation Wheel 11 Installation Guidelines 12 DMX Setup 16 DMX Addressing 17 System Menu 18 Fan Control Noise Operation 23 Dimming Curve 24 DMX Traits Channels Functions Values 25 DMX Traits Color Temperature 32 Remote Device Management RDM 33 Error Codes 34 Maintenance Guidelines 35 Specifications 36 Dimension Drawings 37 CONTEN T S ...

Page 4: ...ase recycle whenever possible SOFTWARE UPDATES For latest software and updating procedure please contact ADJ Customer Support CUSTOMER SUPPORT Contact ADJ Service for any product related service and support needs Also visit forums adj com with questions comments or suggestions ADJ SERVICE USA Monday Friday 8 00am to 4 30pm PST Voice 800 322 6337 Fax 323 582 2941 support adj com ADJ SERVICE EUROPE ...

Page 5: ...air labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of ADJ Products LLC All products covered by this warranty were manufactured after August 15 2012 and bear identifying marks to that effect E ADJ Products LLC reserves the...

Page 6: ... TEMPERATURE 185 F 85 C MAXIMUM AMBIENT TEMPERATURE 104 F 40 C DO NOT TOUCH the fixture housing during operation Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before serving DO NOT shake fixture avoid brute force when installing and or operating fixture DO NOT operate fixture if the power cord is frayed crimped damaged and or if any of the power cord connectors...

Page 7: ...refully during transportation If the fixture contains color flags before transport ensure that color flags inside the unit are placed in an OPEN position For superior impact protection some fixtures are shipped in a custom fitted high density Foam Inlay FIL This FIL must be used inside the road cases for transportation DO NOT TIP THE CASE OVER AND AVOID ALL SHOCKS AND ROUGH HANDLING ESPECIALLY TIP...

Page 8: ...8 OVERVIEW POWER IN AC100 240V 50 60Hz POWER OUT MAX 100 240V 5A DMX OUT DMX IN NET OUT NET IN FUSE T8A 250V LCD Display Carrying Handle Omega Bracket Mounting Points Safety Cable Anchor Point ...

Page 9: ...d remove them With the panel set aside locate the Pattern Bracket Assembly and remove the 4x screws that secure it to the internal housing frame On the Gobo Holders remove the retaining spring and carefully separate the GOBO from the GOBO Holder Lastly remove the flat washer attached to the removed GOBO and attach it to the desired replacement GOBO Install the replacemet Rotating GOBO CAUTION TAKE...

Page 10: ...mm Gobo 7 is 2 8mm thick with Ø Ø19mm I D and Ø Ø23mm O D and fits in the Gobo Holder shown below Gobo Wheel 2 Factory Default Position Assignments Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 Ø 9 Ø22 0mm Gobo Wheel 1 Factory Default Position Assignments Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 Ø0 1in Ø2 0mm 1 9in 47 6mm 0 2in 6 1mm 0 8in 20 0mm 0 9in 23 0mm 0 2in 6 1mm 1 0in 24 5mm 0 ...

Page 11: ...11 COLOR FLAGS COLOR WHEEL ANIMATION WHEEL COLOR FLAGS CYAN MAGENTA YELLOW C T O COLOR WHEEL ANIMATION WHEEL ...

Page 12: ...perly certified to safely hold the combined weight of the fixture s clamps cables and accessories Ambient operating temperature range is 14 F 10 C to 113 F 45 C Fixture s should be installed in areas outside walking paths seating areas or away from areas where unauthorized personnel might reach the fixture by hand NEVER stand directly below the fixture s when rigging removing or servicing Overhead...

Page 13: ...acket before attaching the bracket to the fixture Tighten the quick lock fasteners fully clockwise Pull the safety cable through the opening located on the bottom of the unit and over the trussing system or a safe fixation spot Insert the end in the carabiner and tighten the safety screw SAFETY CABLE ALWAYS ATTACH A SAFETY CABLEWHENEVERINSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE T...

Page 14: ...ty inspection of all installation material and unit If you lack these qualifications do not attempt the installation yourself These installations should be checked by a skilled person once a year SAFETY CABLE ALWAYS ATTACH A SAFETY CABLEWHENEVERINSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT DROP IF THE CLAMP FAILS The Focus Spot 7Z is fully operational in three d...

Page 15: ...filters iris shutters motors belts wiring discharge lamps and LEDs This issue is not specific only to ADJ lighting fixtures it is a common issue with lighting fixtures from all manufacturers Although there is no true way to fully prevent this issue from happening the guidelines below can prevent any potential damage from occurring if followed Contact ADJ Service for more details DO NOT EXPOSE THE ...

Page 16: ...address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation The Focus Spot 5Z can be controlled via DMX 512 protocol The DMX address is set on the front panel of the Focus Spot 5Z Your unit and your DMX controller require a 5 pin XLR connector for data input and data output ...

Page 17: ...e DMX controller The assignment of this starting DMX address is achieved by setting the correct DMX address on the digital control display on the fixture You can set the same starting address for all fixtures or a group of fixtures or set different addresses for each individual fixture Setting all fixtures to the same DMX address will cause all fixtures to react in the same way in other words chan...

Page 18: ... press LCD CONTROL PANEL LOCKOUT When the Key Lock function is activated the control panel will automatically lock after the time set under the Display submenu Screen Saver Delay When the Key Lock function is set to ON the control panel will lock Press and hold the MODE button for 3 seconds to unlock When the Key Lock function is set to ON1 the control panel will lock and will not unlock without a...

Page 19: ...0 Pan Invert ON OFF Tilt Invert ON OFF P T Feedback ON OFF P T Speed Speed 1 Speed 2 Speed 3 Hibernation OFF 01M 99M 15M Zoom Speed Standard Fast Dim Modes Standard Stage TV Architectural Theatre Stage 2 Dim Speed 0 1S 10S LED Refresh Rates 900 1500 1200Hz 2500 4000 5000 6000 10KHz 15KHz 20KHz 25KHz Dim Curve Square Linear Inv Squa S Curve Reset Motors Reset All Motors YES NO Pan Tilt Reset YES NO...

Page 20: ...djustments Program 6 Speed 000 255 Fade 000 255 Program 6 with Adjustments Program 7 Speed 000 255 Fade 000 255 Program 7 with Adjustments Information Fixture Life Time Power On Time xxxxxx Hours P On Time R xxxxxx Hours P On Time Reset Total LED Time LED On Time xxxxxx Hours LED On Time R xxxxxx Hours LED Hourse Reset Fixture Temps LEDs Current T xxx F xxx C Max Resettable T xxx F xxx C Base Temp...

Page 21: ...as either Primary or Secondary unit in a primary secondary set up STATUS SETTINGS In this submenu you are able to access and adjust change Pan Degree Pan Invert Tilt Invert P T Feedback P T Speed and Hibernation FAN SETTINGS In this submenu you are able to select your desired fan speed setting ZOOM SPEED In this submenu you can select between Standard or Fast DIM MODES In this submenu you are able...

Page 22: ...me represents the current LED ON time since the last reset LED Hours Reset With this function you can reset the CURRENT LED ON time that is displayed under LED On Time R FIXTURE TEMPS LED s Current The current LED temperature will be displayed Max Resettable The current highest temperature the LED has reached will be displayed This LED temperature may not be the same as the temperature displayed u...

Page 23: ...ays try to keep noise levels at a minimum The fixture output will only reduce when the LED engine cannot be cooled down to its safe operating range due to high ambient temperature Note Auto is the recommend mode for daily operation of the ADJ Focus Spot 7Z High This mode is only required in very high ambient temperatures when automatic fan speed adjustments are not desired High Fan Speed will cool...

Page 24: ...ec Rise Time Down Time Dimming Curve Ramp Effect 0 sec Fade Time 1 sec Fade Time Rise Time ms Down Time ms Rise Time ms Down Time ms Standard default 0 0 0 0 Stage 780 1100 1540 1660 TV 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 Stage 2 0 1100 0 1660 0 255 0 255 100 Output DMX LINEAR DMX 0 100 Output DMX SQUARE DMX 0 100 Output DMX INVERSE SQUARE DMX 0 100 Ou...

Page 25: ...Yellow 0 to 100 10 000 255 Yellow Fine 0 to 100 6 8 11 000 255 CTO 0 to 100 12 000 255 CTO Fine 0 to 100 7 9 13 White Color Temp Presets 000 023 Open 024 063 See WCT Preset Chat 065 255 6700K 8 10 14 Color Wheel 000 004 Open 005 017 Open Red 018 030 Red 031 043 Red Blue 044 056 Blue 057 069 Blue Green 070 082 Green 083 095 Green Orange 096 108 Orange 109 121 Orange Midnight Blue 122 134 Midnight B...

Page 26: ...cro22 208 215 Macro23 216 223 Macro24 224 231 Macro25 232 239 Macro26 240 247 Macro27 248 255 Random CMY 10 12 16 Gobo Wheel 1 000 009 Open 010 019 Gobo 1 020 029 Gobo 2 030 039 Gobo 3 040 049 Gobo 4 050 059 Gobo 5 060 069 Gobo 6 070 079 Gobo 7 080 094 Gobo 1 shake slow fast 095 109 Gobo 2 shake slow fast 110 124 Gobo 3 shake slow fast 125 139 Gobo 4 shake slow fast 140 154 Gobo 5 shake slow fast ...

Page 27: ...Rotation Fast Slow 192 192 No Rotation 193 255 Counter Clockwise Gobo Rotation Slow Fast 21 000 255 Gobo indexing fine 14 16 22 Shutter 000 031 Shutter closed 032 063 Shutter open 064 095 Strobe Slow to fast 096 127 Shutter open 128 159 Pulse effect Slow to fast 160 191 Shutter open 192 223 Random strobe Slow to fast 224 255 Shutter open 15 17 23 000 255 Dimmer Intensity 0 to 100 18 24 000 255 Dim...

Page 28: ...0 169 Macro16 170 179 Macro17 180 189 Macro18 190 199 Macro19 200 209 Macro20 210 219 Macro21 220 229 Macro22 230 239 Macro23 240 255 Macro24 21 24 32 000 255 Focus 0 to 100 33 000 255 Focus fine 0 to 100 22 25 34 000 255 Zoom Narrow to wide 35 000 255 Zoom fine Narrow to wide 16 bit 23 26 36 Iris 000 191 Max diameter to Min diameter 192 223 Pulse opening fast to slow 224 255 Pulse closing slow to...

Page 29: ...Dim Speed From Fast to Slow 0 1 10s 141 0 1 Sec 142 0 2 Sec 143 0 3 Sec 144 0 4 Sec 145 0 5 Sec 146 0 6 Sec 147 0 7 Sec 148 0 8 Sec 149 0 9 Sec 150 1 0 Sec 151 1 5 Sec 152 2 0 Sec 153 3 0 Sec 154 4 0 Sec 155 5 0 Sec 156 6 0 Sec 157 7 0 Sec 158 8 0 Sec 159 9 0 Sec 160 10 Sec 161 255 Default to Unit Setting 31 42 Dim Curves 000 020 Square 021 040 Linear 041 060 Inv Squa 061 080 S Curve 081 255 No fu...

Page 30: ... 160 Display Backlight OFF Hold 5s 161 164 No function 165 166 Invert Pan ON Hold 3s 167 168 Invert Pan OFF Hold 5s 169 170 Invert Tilt ON Hold 3s 171 172 Invert Tilt OFF Hold 5s 173 173 900 Hz LED Refresh Rate Hold 1s 174 174 910 Hz LED Refresh Rate Hold 1s 175 175 920 Hz LED Refresh Rate Hold 1s 176 176 930 Hz LED Refresh Rate Hold 1s 177 177 940 Hz LED Refresh Rate Hold 1s 178 178 950 Hz LED Re...

Page 31: ...18 1360 Hz LED Refresh Rate Hold 1s 219 219 1370 Hz LED Refresh Rate Hold 1s 220 220 1380 Hz LED Refresh Rate Hold 1s 221 221 1390 Hz LED Refresh Rate Hold 1s 222 222 1400 Hz LED Refresh Rate Hold 1s 223 223 1410 Hz LED Refresh Rate Hold 1s 224 224 1420 Hz LED Refresh Rate Hold 1s 225 225 1430 Hz LED Refresh Rate Hold 1s 226 226 1440 Hz LED Refresh Rate Hold 1s 227 227 1450 Hz LED Refresh Rate Hol...

Page 32: ... 4700 25 2800 45 4800 26 2900 46 4900 27 3000 47 5000 28 3100 48 5100 29 3200 49 5200 30 3300 50 5300 31 3400 51 5400 32 3500 52 5500 33 3600 53 5600 34 3700 54 5700 35 3800 55 5800 36 3900 56 5900 37 4000 57 6000 38 4100 58 6100 39 4200 59 6200 40 4300 60 6300 41 4400 61 6400 42 4500 62 6500 43 4600 63 6600 ...

Page 33: ...Parameters 0x0011 Proxied Device Count 0x0600 Pan Invert 0x0200 Sensor Definition 0x0601 Tilt Invert 0x0201 Sensor Value 0x0602 Pan Tilt Swap 0x0080 Device Model Description 0x0500 Display Invert 0x0081 Manufacturer Label 0x0501 Display Level 0x0082 Device Label 0x0603 Realtime Clock 0x00E0 DMX Personality 0x1010 Power State 0x00E1 DMX Personality Description 0x1031 Preset Playback 0x0400 Device H...

Page 34: ...Prism2 Prism2Rot Frost1 Frost2 Zoom Focus Base Temp Head Temp LED Fan1 LED Fan3 LED Fan4 Focus Fan Gobo Fan Base Fan Movement is not located in the default position after the reset This message will appear after a fixture reset if the magnetic indexing circuit malfunctions sensor failed or magnet is missing or there is a motor failure defective motor or a defective motor IC drive on the main PCB ...

Page 35: ...nts during routine inspections A detailed electrical check by an approved electrical engineer every three months to make sure the circuit contacts are in good condition and prevent overheating Be sure all screws and fasteners are securely tightened at all times Loose screws may fall out during normal operation resulting in damage or injury as larger parts could fall Check for any deformations on t...

Page 36: ...angeable Rotating Indexing Gobos 2 7 Interchangeable Rotating Indexing Gobos CONTROL CONNECTIONS 3 DMX Channel Modes 30 34 45 DMX512 ArtNet and sACN protocols Aria XT Wireless DMX RDM Remote Device Management compliant 6 Button Touch Control Panel Full Color 180 Reversible LCD Menu Display 8 16 Bit Resolution Adjustable Movement 3 5 pin XLR DMX In Out Locking In Out power connections With Wired Di...

Page 37: ...7 DIMENSIO N D RAW ING S Dimensions not to scale 9 2in 234mm 14 2in 360mm 14 7in 374mm 25 7in 653mm 17 2in 436mm 18 8in 477 5mm 19 8in 502 2mm 8 7in 222mm 11 2in 285mm 7 1in 180mm 6 8in 173mm 5 6in 143mm ...

Page 38: ...he moving head radial movement arc of the ADJ Focus Spot 7Z is approximately 11 inches 279mm To avoid damaging fixtures through convergent head movement radial interference impacts maintain a 22 4in 570mm minimum center to center distance between fixtures Ø22 0in Ø558 0mm 24 0in 608 8mm ref 2 0in 50 8mm Min ...

Page 39: ...ference to radio communications However there is no guarantee that interference will not occur in a particular installation If this device does cause harmful interference to radio or television reception which can be deter mined by turning the device off and on the user is encouraged to try to correct the interference by one or more of the following methods Reorient or relocate the device increase...

Page 40: ......

Reviews: