background image

ADJ Products, LLC  -  www.adj.com  - Focus Spot One User Manual Page 9

  

Focus Spot One

                                                                                      

CAD Drawing

Summary of Contents for FOC598

Page 1: ...User Manual FOCUS SPOT ONE...

Page 2: ...r indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installatio...

Page 3: ...ving head mini LED wash The Focus Spot One can operate as a stand alone fixture or in a Primary Secondary set up The Focus Spot One has three operating modes a sound active show mode DMX controlled Th...

Page 4: ...pot One carries a 2 year 730 days limited warranty Please fill out the enclosed warranty card to validate your purchase and warranty You may also register your product online at www adj com All return...

Page 5: ...nt this unit in an area that will allow proper ventilation Allow about 6 15cm between this device and a wall Do not attempt to operate this unit if has been damaged This unit is intended for indoor us...

Page 6: ...URE AT DISTANCES SHORTER THAN 11 feet 3 3m DO NOT OPERATE FIXTURE WITH DAMAGED OR MISSING EXTERNAL COVER PROTECTIVE LENS DO NOT LOOK DIRECTLY INTO THE UV LIGHT AND OR VIEW UV LIGHT DIRECTLY WITH OPTIC...

Page 7: ...ad limits instal lation material being used and periodic safety inspection of all installation material and unit If you lack these qualifications do not attempt the installation yourself The installat...

Page 8: ...fall outside of this range This will allow the fixture to run at its best and help prolong the fixture life Screw one clamp via an M12 screw and nut to the included bracket Attach the bracket using t...

Page 9: ...ADJ Products LLC www adj com Focus Spot One User Manual Page 9 Focus Spot One CAD Drawing...

Page 10: ...und activation 3 Button MENU To select the programming functions UP To go backward in the selected functions DOWN To go forward in the selected functions ENTER To confirm the selected functions 4 Disp...

Page 11: ...ures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be...

Page 12: ...t to avoid erratic behavior A terminator is a 110 120 ohm 1 4 watt resistor which is connected between pins 2 and 3 of a male XLR connects DATA and DATA This unit is inserted in the female XLR connect...

Page 13: ...ADJ Products LLC www adj com Focus Spot One User Manual Page 13 Focus Spot One 15 Channel Mode...

Page 14: ...ADJ Products LLC www adj com Focus Spot One User Manual Page 14 Focus Spot One 15 Channel Mode...

Page 15: ...ADJ Products LLC www adj com Focus Spot One User Manual Page 15 Focus Spot One 15 Channel Mode...

Page 16: ...ADJ Products LLC www adj com Focus Spot One User Manual Page 16 Focus Spot One 17 Channel Mode...

Page 17: ...ADJ Products LLC www adj com Focus Spot One User Manual Page 17 Focus Spot One 17 Channel Mode...

Page 18: ...ADJ Products LLC www adj com Focus Spot One User Manual Page 18 Focus Spot One 17 Channel Mode...

Page 19: ...ADJ Products LLC www adj com Focus Spot One User Manual Page 19 Focus Spot One System Menu...

Page 20: ...ADJ Products LLC www adj com Focus Spot One User Manual Page 20 Focus Spot One System Menu Software Version 1 3...

Page 21: ...splayed DMX channel mode Press the UP or DOWN buttons to find your desired Channel mode 3 Press ENTER to confirm PRI SEC Mode This will let you set unit as a primary or secondary in a primary secondar...

Page 22: ...Sound Sense is displayed press ENTER 2 Press the UP or DOWN buttons to adjust the sensitivity level The sensitivity level can be adjusted between 0 the lowest and 100 most sensitive 3 Press ENTER to...

Page 23: ...s function you can make the backlight automatically turn off after one minute 1 Press the MENU button until Back Light is displayed press ENTER 2 Either On or Off will now be displayed Press the UP or...

Page 24: ...il PRO defaults is displayed press ENTER Either Yes or No will be displayed 2 To restore factory settings press the UP or DOWN buttons until Yes is displayed press ENTER to confim If you do not wish r...

Page 25: ...R 2 Use the UP and DOWN buttons to make your adjustments and then press ENTER to confirm Press the MENU button for one second to exit Gobo Offset Setting adjustment for the gobo wheel 1 Press the ENTE...

Page 26: ...your own programs 5 Follow the instructions in the System Menu section to select your desired DMX channel mode and to set the DMX address 6 For longer cable runs more than a 100 feet use a terminator...

Page 27: ...r cable runs it is highly adviseable to use a terminator on the last fixture 2 On the Primary unit press the MENU button until PRI SEC Mode is displayed and press EN TER Use the UP and DOWN buttons to...

Page 28: ...blackout the fixture FULL ON Hold this button down to fully light up the unit When you let the button go the unit will return to its previous state FADE GOBO Press this button once to access gobo whe...

Page 29: ...you are able to swing the head back See step 2 in the Re moving the Head Casing section of this manual You will now be able to access the gobo wheel Turn the wheel with your hand until you come across...

Page 30: ...Focus Spot One Removing the Head Casing ADJ Products LLC www adj com Focus Spot One User Manual Page 30...

Page 31: ...Focus Spot One Target Mode TARGET MODE MAX PAN DEGREES TILT DEGREES 0 0 540 1 100 240 2 190 330 3 280 420 4 370 510 ADJ Products LLC www adj com Focus Spot One User Manual Page 31...

Page 32: ...Focus Spot One Photometric Chart Focus Spot One Dimmer Curve Chart ADJ Products LLC www adj com Focus Spot One User Manual Page 32...

Page 33: ...cleaner and a soft cloth to wipe down the outside casing Use a brush to wipe down the cooling vents and fan grill Clean the external optics with glass cleaner and a soft cloth every 20 days Clean the...

Page 34: ...on of defects in material or workman ship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the so...

Page 35: ...DMX 2 DMX Channel Modes 15 Channel Mode 17 Channel Mode Sound Active Yes Working Position Any Safe Secure Position Warranty 2 Year 730 days Please Note Specifications and improvements in the design o...

Page 36: ......

Reviews: