ADJ Products, LLC - www.adj.com - Flash Kling Panel 64 Instruction Manual Page 6
ADJ Products, LLC - www.adj.com - Flash Kling Panel 64 Instruction Manual Page 5
Flash Kling Panel 64 Connections
Flash Kling Panel 64 Operation
Control Using Kling-net or Art-Net:
1. Install one of the recommended operating softwares onto your
computer. Recommended softwares; Arkaos Media Master
Express, Media Master Pro, or LED Master (Sold Separately).
2. Connect the panels via CAT 5 Straight Network cable. When
creating your own custom cable, use RJ45 Straight Network
cable.
3. Map the fixtures using KlingNetMapper or Art-Net Mapper.
4. Control the fixtures using ArKaos or Art-Net software. Please refer
to the media playback software user manual for further instruc-
tions.
Note: ArKaos Kling-Net requires a gigabit (1000 mbps) Ethernet card
and network router for a smoother operation.
Connecting to Power and Data:
When connecting to power, the LED indicator on the bottom of the
unit should glow a solid red if the unit is receiving power.
When the unit is receiving a data signal, the LED indicator will flash
yellow.
Note: The LED indicator may only flash when pressing the mouse and
moving the indicator arrow around in the grid.
Installation method 1:
Note: Do not daisy-chain more than 50pcs LED panels from the computer,and use an Ethernet Switch if more
than 50pcs LED lights are being controlled.
Installation method 2:
Note:1.The Ethernet Switch must be Gigabit Switch.
2. Do not daisy-chain more than 50pcs LED panels from a single network port of the Ethernet Switch.
3. Maximum 2 output network ports of the Ethernet Switch can be used.So the system can control 100pcs
panels maximum.
When connecting you must use a CAT 5 Straight Network cable.
When connecting you must use a CAT 5 Straight Network cable.
Flash Kling Panel 64 Cleaning
Due to fog residue, smoke, and dust cleaning the internal and exter-
nal optical lenses must be carried out periodically to optimize light
output.
1. Use normal glass cleaner and a soft cloth to wipe down the
outside casing.
2. Clean the external optics with glass cleaner and a soft cloth
every 20 days.
3. Always be sure to dry all parts completely before plugging
the unit back in.
Cleaning frequency depends on the environment in which the fixture
operates (i.e. smoke, fog residue, dust, dew).
Flash Kling Panel 64 Trouble Shooting
Listed below are a few common problems the user may encounter,
with solutions.
No light output from the unit;
1.
Be sure the LED indicator on the back of the unit is on and in a
solid state.
Unit is not receiving data;
1. Check the LED indictator (same LED as the Power indicator). If the
LED is flashing, you’re a receiving data. When moving your mouse
arrow around in the grid, the LED will flash if you are receiving
data.
2. Be sure you are using a CAT 5 Straight Network cable.
If problems are not resolved; Contact ADJ for service.
1-800-322-6337
Flash Kling Panel 64 Daisy-Chaining Units
Do not daisy-chain more than 50 Panels when connecting directly to
a computer. To daisy-chain more than 50 Panels you must use a Eth-
ernet Switch. When using a Ethernet Switch, do not daisy-chain more
than 50 Panels from a single network port of the Ethernet Switch. A
maximum 2 output network ports of the Ethernet Switch can be used.
So the system can control 100 Panels maximum, no more. See the