INSTALLATION
FLAMMABLE MATERIAL WARNING
Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or pyrotech-
nics.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or installations.
MINIMUM DISTANCE TO OBJECTS/SURFACES IS 6.6 FEET (2 METERS).
MINIMUM DISTANCE OF INFLAMMABLE MATERIALS FROM THE SURFACE IS 1.6
FEET (0.5 METER)
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
• Fixture MUST be installed following all local, national, and country commercial electrical and con-
struction codes and regulations.
• Before rigging/mounting a single fixture or multiple fixtures to any metal truss/structure or placing
the fixture(s) on any surface, a professional equipment installer MUST be consulted to determine
if the metal truss/structure or surface is properly certified to safely hold the combined weight of
the fixture(s), clamps, cables, and accessories.
• Maximum fixture ambient operating temperature is 113°F (45°C). Do not use operate the fixture
when ambient temperature exceeds this value!
• Fixture(s) should be installed in areas outside walking paths, seating areas, or areas were unau-
thorized personnel might reach the fixture by hand.
• NEVER stand directly below the fixture(s) when rigging, removing, or servicing.
• Overhead fixture installation must always be secured with a secondary safety attachment, such
as an appropriately rated safety cable.
• Allow approximately 60 minutes for the fixture to cool down before servicing.
IP RATING
This device is IP65 rated. This means that the unit is dust-tight, and protected against low-
pressure jets of water from any direction.
RIGGING
Overhead rigging requires extensive experience, including calculating working load limits,
installation material being used, and periodic safety inspection of all installation material and
the fixture, among other skills. If you lack these qualifications, do not attempt the installation
yourself. Improper installation can result in bodily injury.