Page 2: ...amages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and opera tion of this product Europe Energy Saving Notice Energy Saving Matters EuP 2009 125 EC Saving electric energy is a key to help protecting...

Page 3: ... 7 Overview 8 Installation 9 Accessory Installation 13 Remote Device Management RDM 14 Control Panel 15 System Menu 16 DMX Setup 19 DMX Traits 21 Color Macros Chart 24 Dim Modes 26 Daisy Chain Power Linking Cleaning and Maintenance 27 Dimensional Drawings 28 Specifications 29 Accessory and Ordering Information 30 ...

Page 4: ... this manual with the unit for future reference Customer Support Contact ADJ Service for any product related service and support needs Also visit forums adj com with questions comments or suggestions Parts To purchase parts online visit http parts adj com US http www adjparts eu EU ADJ SERVICE USA Monday Friday 8 00am to 4 30pm PST Voice 800 322 6337 Fax 323 582 2941 support adj com ADJ SERVICE EU...

Page 5: ...arranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of ADJ Products LLC All products covered by this warranty were manufactured after August 15 2012 and bear identifying marks to that effect E ADJ Pr...

Page 6: ...fixture and the second digit Water Protection indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture such as this one has been designed and tested to protect against the ingress of dust 6 and low pressure water jets from any direction 5 WARRANTY REGISTRATION The Encore LP5IP carries a 2 year limited warranty Please fill out the enclosed warranty card to...

Page 7: ...IMUM AMBIENT TEMPERATURE IS 113 F 45 C DO NOT OPERATE THE DEVICE WHEN AMBIENT TEMPERATURE EXCEEDS THIS VALUE MINIMUM DISTANCE TO FLAMMABLE MATERIALS FROM THE SURFACE IS 1 6 FEET 0 5 METER DO NOT TOUCH the fixture housing during operation Turn OFF the power and allow approximately 60 minutes for the fixture to cool down before servicing DO NOT shake fixture and avoid brute force when installing and or...

Page 8: ...8 OVERVIEW ...

Page 9: ...amps cables and accessories Maximum fixture ambient operating temperature is 113 F 45 C Do not use operate the fixture when ambient temperature exceeds this value Fixture s should be installed in areas outside walking paths seating areas or areas were unau thorized personnel might reach the fixture by hand NEVER stand directly below the fixture s when rigging removing or servicing Overhead fixture in...

Page 10: ...lustra tion below When mounting the fixture to a truss or any other suspended or overhead installation be sure to secure an appropriately rated clamp not included to the yoke and attach a separate SAFETY CABLE of the appropriate weight rating to the safety cable loop SAFETY CABLE ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE THAT THE FIXTURE WIL...

Page 11: ...the mounting yoke Tighten the nut onto the threaded bolt to secure the mounted device in place CAUTION MAKE SURE THAT THE TRIPOD LEGS AND ALL TELESCOPING ELEMENTS OF THE TRIPOD STAND ARE LOCKED IN PLACE BEFORE INSTALL ING THE DEVICE ATOP THE STAND POSITION THE TRIPOD STAND AND MOUNTED DEVICE ONLY ON FLAT STABLE SURFACES DE PLOY TRIPOD LEGS FULLY IN ORDER TO MAXI MIZE STABILITY ...

Page 12: ...s shutters motors belts wiring discharge lamps and LEDs This issue is not unique to ADJ lighting fixtures but rather it is a common issue with lighting fixtures from all manufacturers Although there is no true way to fully prevent this issue from happening the guide lines below can reduce the risk of any potential damage if followed Contact ADJ Service for more details DO NOT EXPOSE THE FIXTURE AN...

Page 13: ... the included frost filter simply align the four 4 holes on the frost filter with the four 4 holes located around the edge of the lens on the fixture Insert a screw into each holes and tighten to secure the frost filter in place Refer to the illustration below ...

Page 14: ...ible RDM enabled con troller to send out a signal to devices on the wire as well as allowing the fixture to respond known as a GET command The controller can then use its SET command to modify settings that would typically have to be changed or viewed directly via the unit s display screen including the DMX Address DMX Channel Mode and Temperature Sensors Please be aware that not all RDM devices s...

Page 15: ...or confirm selection This device features two different settings for locking the keypad Setting Lock to ON requires the user to simply press and hold the MODE button for 10 seconds to unlock the keypad Setting Lock to ON1 provides an additional safeguard against accidental unlocking by requiring a passcode to unlock the device To unlock press the MODE button so that LOCKED is dis played on the scr...

Page 16: ... Set primary mode Secondary On Off Set secondary mode Fan Set Auto High Silent Dim Mode Standard Stage TV Archi Theatre Stage 2 Dim Speed 0 1s 10s Dim Curve Square Linear Inv Squa S Curve LED Rfrsh 900 1000 1100 1200 1300 1400 1500 2500 4000 5000 10k 15k 20k 25k Set LED refresh rate default 1200 Hz Display SaveDelay 1 10 Amount of time w o activity before screen powers off Lock ON Press MODE for 1...

Page 17: ...5 Manually adjust strobing MastrDim 000 255 Master dimmer AutoProg 000 255 Select automatic program ProgSpd 000 255 Set program speed ProgFade 000 255 Set program fade INTPROGS Prog 0 Speed 000 255 Fade 000 255 Prog 1 Speed 000 255 Fade 000 255 Prog 7 Speed 000 255 Fade 000 255 INFO Hours PwrOnHr1 xxxxxx Hrs Total hours that fixture has been powered on Non resettable PwrOnHr2 xxxxxx Hrs Hours that...

Page 18: ...18 SYSTEM MENU INFO contin ued DMX Values Red Displays current DMX values for each DMX channel Green AutoProg SoftVers x xx Displays current software version ...

Page 19: ...ixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation The Encore LP5IP can be controlled via DMX 512 protocol and features multiple DMX channel modes Your unit and your DMX control ler require a 5 pin XLR connector for data input and data outpu...

Page 20: ...me DMX address will cause all fixtures to react in the same way In this case please note that changing the settings of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start to listen to the channel num ber you have set based on the quantity of DMX channels of each fixture That means changing the settings of one channel will ...

Page 21: ...olor Temperature 2700K 7000K Linear 7 7 7 Color Temperature Macros 000 Off 001 054 2700K 055 109 3200K 110 164 4000K 165 219 5600K 220 255 6500K 5 8 8 8 Shutter Strobe 000 031 LEDs Off 032 063 LEDs On 064 095 Strobe effect slow to fast 096 127 LEDs On 128 159 Pulse effect in sequences 160 191 LEDs On 192 223 Random strobe effect slow to fast 224 255 LEDs On 6 9 9 9 000 255 Dimmer Intensity 0 100 7...

Page 22: ...041 060 Stage 061 080 TV 081 100 Architectural 101 120 Theatre 121 140 Stage 2 141 0 1s dim speed 142 0 2s dim speed 143 0 3s dim speed 144 0 4s dim speed 145 0 5s dim speed 146 10 6s dim speed 147 0 7s dim speed 148 0 8s dim speed 149 0 9s dim speed 150 1 0s dim speed 151 1 5s dim speed 152 2 0s dim speed 153 3 0s dim speed 154 4 0s dim speed 155 5 0s dim speed 156 6 0s dim speed 157 7 0s dim spe...

Page 23: ...061 080 S Curve 081 255 No function 13 16 Refresh Rate 000 015 Default to Unit Setting 016 030 900 Hz 031 045 1000 Hz 046 060 1100 Hz 061 075 1200 Hz 076 090 1300 Hz 091 105 1400 Hz 106 120 1500 Hz 121 135 2500 Hz 136 150 4000 Hz 151 165 5000 Hz 166 180 10000 Hz 181 195 15000 Hz 196 210 20000 Hz 211 225 25000 Hz 226 255 No Function ...

Page 24: ...4 83 14 053 056 255 93 182 93 15 057 060 255 96 236 96 16 061 064 238 93 255 93 17 065 068 196 87 255 87 18 069 072 150 90 255 90 19 073 076 100 77 255 77 20 077 080 77 100 255 77 21 081 084 67 148 255 67 22 085 088 77 195 255 77 23 089 092 77 234 255 77 24 093 096 158 255 144 144 25 097 100 255 251 153 153 26 101 104 255 175 147 147 27 105 108 255 138 186 138 28 109 112 255 147 251 147 29 113 116...

Page 25: ...2 163 0 46 181 184 0 38 86 0 47 185 188 0 142 208 0 48 189 192 52 148 209 0 49 193 196 1 134 201 0 50 197 200 0 145 212 0 51 201 204 0 121 192 0 52 205 208 0 129 184 0 53 209 212 0 83 115 0 54 213 216 0 97 166 0 55 217 220 1 100 167 0 56 221 224 0 40 86 0 57 225 228 209 219 182 0 58 229 232 42 165 85 0 59 233 236 0 46 35 0 60 237 240 8 107 222 0 61 241 244 255 0 0 0 62 245 248 0 255 0 0 63 249 252...

Page 26: ...26 DIM MODES ...

Page 27: ...ree months to make sure the circuit contacts are in good condition and prevent overheating Be sure all screws and fasteners are securely tightened at all times Loose screws may fall out during normal operation resulting in damage or injury as larger parts could fall Check for any deformations on the housing color lenses rigging hardware and rigging points ceiling suspension trussing Deformations i...

Page 28: ...28 DIMENSIONAL DRAWINGS Dimensions may not be drawn to scale ...

Page 29: ...e Dimming Modes Standard Stage TV Architectural Theatre Stage 2 4 selectable Dim Curves Linear Square Inv Squa S Curve Adjustable Refresh Rate 14 presets from 900 25 000Hz Flicker Free operation No flickering on camera LED pulse and strobe effect Electronic Dimming 0 100 6 DMX Modes 4 7 8 10 13 16 channel Quiet fan mode CONSTRUCTION IP65 Rated Ingress Protection against liquid snow dust and sand A...

Page 30: ... INFORMATION SKU NUMBER DESCRIPTION ENC355 ADJ Encore LP5IP ELP5L100 100 degree Frost Filter ELP5L60 60 degree Frost Filter ELP5L30X60 30x60 degree Frost Filter ELP5L1X40 1x40 degree Frost Filter ELP5L20 20 degree Frost Filter ...