ADJ Dotz Bar 1.4 User Instructions Download Page 3

Power Supply:

 The ADJ Dotz Bar 1.4 contains a automatic voltage 

switch,  which  will  auto  sense  the  voltage  when  it  is  plugged  into  a 

power source. With this switch there is no need to worry about the cor-

rect power voltage, this unit can be plugged in anywhere. Always use 

the PowerCon cord that came with the unit.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Dotz Bar 1.4 can be controlled via DMX-512 protocol. The Dotz Bar 

1.4 has 5 DMX Channel Modes. The DMX address is set on the rear 

panel of the Dotz Bar 1.4. Your unit and your DMX controller require 

a  approved  DMX-512  110  Ohm  Data  cable  for  data  input  and  data 

output  (Figure  1).  We  recommend  Accu-Cable 

DMX cables. If you are making your own cables, 

be sure to use standard 110-120 Ohm shielded 

cable  (This  cable  may  be  purchased  at  almost 

all professional sound and lighting stores). Your 

cables should be made with a male and female 

XLR connector on either end of the cable. Also 

remember that DMX cable must be daisy chained 

and cannot be split.

ADJ Products, LLC  -  www.adj.com  - Dotz Bar 1.4 User Manual Page 5

  Dotz Bar 1.4                                                             Set Up

Figure 1

  Dotz Bar 1.4                                         Safety Precautions

ADJ Products, LLC  -  www.adj.com  - Dotz Bar 1.4 User Manual Page 4

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids  into or on to your unit.

•   Be sure that the local power outlet match that of the required volt- 

   age for your unit.

•   Do not attempt to operate this unit if the power cord has been   

   frayed or broken. Do not attempt to remove or break off the ground 

   prong from the electrical cord. This prong is used to reduce the risk  

   of electrical shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Never plug this unit in to a dimmer pack

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out`  

   doors voids all warranties.

•   During long periods of non-use, disconnect the unit’s main power.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to the point they exit from the unit. 

• Cleaning -The fixture should be cleaned only as recommended by  

  t he manufacturer. See page 21 for cleaning details.

•   Heat -The appliance should be situated away from heat sources  

   such as radiators, heat registers, stoves, or other appliances (inclu-

   d ing amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. The power-supply cord or the plug has been damaged.

    B. Objects have fallen, or liquid has been spilled into the appliance.

    C. The appliance has been exposed to rain or water.

    D. The appliance does not appear to operate normally or exhibits a  

        marked change in performance.

Summary of Contents for Dotz Bar 1.4

Page 1: ...rands and product names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipm...

Page 2: ...ng shipping If the carton appears to be damaged carefully inspect your fixture for any damage and be sure all accessories necessary to operate the unit has arrived intact In the case damage has been f...

Page 3: ...emale XLR connector on either end of the cable Also remember that DMX cable must be daisy chained and cannot be split ADJ Products LLC www adj com Dotz Bar 1 4 User Manual Page 5 Dotz Bar 1 4 Set Up F...

Page 4: ...ransmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixture 1 2 3 Figure 4 5 Pin XLR DMX Connect...

Page 5: ...e displayed ON will have the unit light up right to left OFF will have the unit light up left to right Use the UP or DOWN buttons to find your desired setting and ADJ Products LLC www adj com Dotz Bar...

Page 6: ...oller to control the chases and patterns dimmer and strobe A DMX controller allows you to create unique programs tailored to your individual needs The Dotz Bar 1 4 has 5 DMX channel modes a 3 Channel...

Page 7: ...MASTER DIMMER 0 255 0 100 5 STROBING 0 255 SLOW FAST 6 DIMMER CURVES 0 41 STANDARD 42 84 STAGE 85 127 TV 128 170 ARCHITECTURAL 171 213 THEATER 214 255 DEFAULT TO UNIT CURVE SETTING Dotz Bar 1 4 6 Chan...

Page 8: ...LOW 4 200 207 COLOR FLOW 5 208 215 COLOR FLOW 6 216 223 COLOR FLOW 7 Dotz Bar 1 4 8 Channel Mode ADJ Products LLC www adj com Dotz Bar 1 4 User Manual Page 14 Channel Value Function 4 COLOR MACROS PRO...

Page 9: ...55 0 100 11 GREEN 4 0 255 0 100 12 BLUE 4 0 255 0 100 Dotz Bar 1 4 12 Channel Mode Channel Value Function 1 RED 1 0 255 0 100 2 GREEN 1 0 255 0 100 3 BLUE 1 0 255 0 100 4 RED 2 0 255 0 100 5 GREEN 2 0...

Page 10: ...LOR CHANGE 168 175 COLOR FLOW 1 176 183 COLOR FLOW 2 184 191 COLOR FLOW 3 192 199 COLOR FLOW 4 200 207 COLOR FLOW 5 208 215 COLOR FLOW 6 216 223 COLOR FLOW 7 216 223 COLOR FLOW 7 224 231 COLOR FLOW 8...

Page 11: ...Dotz Bar 1 4 Cleaning Due to fog residue smoke and dust cleaning the internal and exter nal optical lenses must be carried out periodically to optimize light output 1 Use a soft cloth to wipe down th...

Page 12: ...the right to make changes in design and or improvements upon its products without any obligation to include these changes in any products theretofore manufactured No warranty whether expressed or imp...