ADJ 818651024692 User Manual Download Page 19

19

SYSTEM MENU

Addr: DMX-512 Address Setting.

Select “Addr,” then press the ENTER button. When the display begins to blink, use the DOWN and 

UP buttons to change the DMX-512 address (001-512). Once the address has been selected, press 

the ENTER button to confirm, or press the MENU button to exit without making any change. The 

system will return to the main menu after 8 seconds of inactivity. 

ChNd: Channel Mode.

Select “ChNd,” then press the ENTER button. Use the DOWN and UP buttons to select the channel 

mode from the following options: 

•  1-Channel Mode

•  2-Channel Mode

•  2A-Channel Mode

•  3-Channel Mode

•  4-Channel Mode

•  6-Channel Mode

Once you have made your selection, press the ENTER button to confirm, or exit to the main menu 

without making any changes by pressing the MENU button. The system will return to the main menu 

after 8 seconds of inactivity.

dINd: Dimmer Curve.

Select “dINd,” then press the ENTER button. Use the DOWN and UP buttons to select from the fol-

lowing dimmer curves: 

•  Standard

•  Stage

•  TV

•  Architec

•  Theatre

•  Stage2 

Once you have made you selection, press the ENTER button to confirm, or press the MENU but-

ton to exit without making any changes. The system will return to the main menu after 8 seconds of 

inactivity.

Und: Tungsten Filament Effect.

Select “Und,” then press the ENTER button. Use the DOWN and UP buttons to select “on” or “off.” 

Once you have made your selection, press the ENTER button to confirm, or press MENU to exit 

without making any changes.

dNSt: DMX State.

Select “dNSt,” then press the ENTER button. Use the DOWN and UP buttons to select from the fol-

lowing options:

•  “bLNd”: Blackout

•  “HoLd”: Hold last state

•  “NAnd”: Manual mode

Once you have made your selection, press the ENTER button to confirm, or press MENU to exit 

without making any changes.

Summary of Contents for 818651024692

Page 1: ...User Manual ENCORE BURST 200...

Page 2: ...r unsafe insufficient and negligent assembly installation rigging and opera tion of this product ADJ USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 2650 323 532 2941 fax www adj com support ameri...

Page 3: ...imited Warranty USA Only 5 Safety Guidelines 6 Maintenance Guidelines 8 Fixture Overview 9 Installation Instructions 10 System Menu 18 Dimming Curve 21 DMX Channel Functions and Values 22 Specificatio...

Page 4: ...shipping carton in the trash Please recycle whenever possible CUSTOMER SUPPORT Contact ADJ Service for any product related service and support needs Also visit forums adj com with questions comments...

Page 5: ...cts in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discreti...

Page 6: ...ge and or personal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF AS DOING SO WILL VOID YOUR MANUF...

Page 7: ...wall for proper cooling When installing fixture in a suspended environment always use mounting hardware that is at least M10 x 25 mm and always install fixture with an appropriately rated safety cable...

Page 8: ...ice technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed electrical check by...

Page 9: ...FIXTURE OVERVIEW 9 INCLUDED ITEMS Omega Bracket Yoke Bracket Kit Power Cable...

Page 10: ...ture is NOT suitable for permanent outdoor and or marine environment installations Installing this fixture in permanent outdoor and or marine envi ronment installation may cause corrosion and or exces...

Page 11: ...afely hold the combined weight of the fixture s clamps cables and accessories Maximum ambient operating temperature is 104 F 40 C Fixture s should be installed in areas outside walking paths seating a...

Page 12: ...talla tion steps below INSTALLATION INSTRUCTIONS OMEGA BRACKET MUST BE USED WHEN CONNECTING FIXTURES TOGETHER 1 Attach the Omega Bracket to the fixture using 2 of the 4 included interlocking pins 2 To...

Page 13: ...ON INSTRUCTIONS YOKE BRACKET FOR SINGLE FIXTURE INSTALLATION ONLY DO NOT USE WHEN CONNECTING MULTIPLE FIXTURES TOGETHER 1 Attach the Yoke Bracket to the fixture using the included hardware 2 Adjust th...

Page 14: ...he first fixture as described on the previous page 2 Push out the spring loaded bracket on the top and bottom edges of each fixture then slide fix tures together and align the holes on both spring loa...

Page 15: ...port 10x the total weight of the entire assembly 10 x combined weight of 10 fixtures and any associated hardware and accesso ries The first fixture in the chain must be attached to the structure using...

Page 16: ...ed safety cable that can hold 10 times the weight of the fixture WHEN INSTALLING THE FIXTURE IN A SUSPENDED ENVIRONMENT ALWAYS ATTACH AN INDEPENDENT SAFETY CABLE BETWEEN THE TRUSS STRUC TURE AND THE F...

Page 17: ...efault 0 degree position to 7 5 or 15 degrees UP and 7 5 and 15 0 degrees DOWN Simply push the LED lens array either UP or DOWN by hand until the desired angle is achieved The LED lens array movement...

Page 18: ...ck of the fixture see image below To access the system menu press and hold the MENU button for 3 seconds The LCD Menu Control Display will shut OFF auto matically about 1 minute from the last button p...

Page 19: ...he system will return to the main menu after 8 seconds of inactivity dINd Dimmer Curve Select dINd then press the ENTER button Use the DOWN and UP buttons to select from the fol lowing dimmer curves S...

Page 20: ...note that strobe is only available when the device is set to 4 Channel Mode or 6 Channel Mode Press ENTER to confirm your selection then use the DOWN and UP buttons to adjust the value between 000 255...

Page 21: ...21 DIMMING CURVE The fixture includes 6 different dimming curve modes which can selected from either the system menu or via DMX The graph below provides details on each dimming curve mode...

Page 22: ...Intensity 0 100 5 000 255 Master Dimmer Intensity Fine 3 3 Shutter Strobe 000 031 LED Off 032 063 LED On 064 095 Strobe Effect slow to fast 096 127 LED On 128 159 Strobe Pulse Effect in Sequences slo...

Page 23: ...ter ference received including interference that may cause undesired operation FCC RADIO FREQUENCY INTERFERENCE WARNINGS INSTRUCTIONS This product has been tested and found to comply with the limits a...

Page 24: ...24 DIMENSIONAL DRAWINGS...

Page 25: ...25 DIMENSIONAL DRAWINGS...

Page 26: ......

Reviews: