Technical Specification
(1). Overall Dimension
180 x 80 x 40 mm
(2). Power Supply
4 x 1.5V Size AA batteries with power consumption 16mA
(3). Display
Special 4 x 16 character big screen LCD lattice (valid visual field 61.6 x 25.2 mm)
(4). Type of Test Cable
STP/UTP twin twisted cable, coaxial cable, telephone line
(5). Working Ambient Temperature
-10C= +60C
(6). Tester Port
Tester RJ45 master port (M), tester LOOPBACK RJ45 port (L), far-end recognizer
RJ45 port (R). The extra BNC and RJ11 converters are used to measure and
check the continuity of coaxial cable and telephone line.
(7). Length Measurement of Twin Twisted Cable
Scope: 1 350 M (31,200ft)
Calibration accuracy: 3% (+/- 0.5M or +/- 1.5 ft) (calibrating cable > 5 M)
Shipment accuracy: 5% (+/- 0.5 M or +/- 1.5 ft). (AMP, AT&T Class 5 cable)
Display: M or ft.
(8). Length Calibration:
User can set calibration factor by himself with a given length cable. The length of
calibrating cable is more than 5 M.
(9). Wire Sequence and Locating Cable Error:
Check errors such as open circuit, short circuit, reverse connection, cross- over
or cross-talk interference.
(10). Locating Cable
8 far-
(11). Automatic Time-delay Shut Off Time:
The tester does not operate for 30 minutes.