Adidas ADIPOWER TR Instructions Manual Download Page 5

CHRONO MODE

1. Press B to enter chrono mode.

2. Press C to start chrono.

3. Press D to stop chrono.

4. Press and hold D for 2 seconds to reset chrono.

    NOTE: Maximum chrono time is 23 hours, 59 minutes, and 59 seconds. When chrono reaches maximum time, 

    it will stop running. Press and hold D to reset value to run chrono. 1/00s resolution for first 59 minutes and 

   59.99 seconds.

RESPONSE / FITNESS CONTROL / NALOA / LAHAR

NORMAL TIME DISPLAY

1. Press A for EL.

2. Press B to change modes. Mode sequence is time, my log, alarm, timer.

3. Press D to flash to TIME 2; press and hold D to toggle TIME 1 and TIME 2. 

4. Press E to toggle chime on/off. Press and hold E for chronograph mode 

    on 50 Lap Digital Models.  On 10-30 Lap Digital Models, press and 

    hold E for timer mode.

5. Press and hold A, B, D and E for 5 seconds to master reset the watch. 

     All data will be erased, and all settings will be set to default.

TIME/CALENDAR SETTING

1. In normal time display, press and hold A to enter setting mode; hour 

     will begin flashing.

2. Press E to increase setting value. Press D to decrease setting value.

3. Press B to set and advance to next setting value.

4. Setting sequence is hour, minute, second, year, month, date, 

    12/24-hour time, date format.

5. Press A to save data and exit setting mode.

ALARM MODE

1. Press B to change to alarm mode.

2. Press D to toggle between alarms 1 and 2.

3. Press E to toggle alarm on/off.

ALARM SETTING

1. In alarm mode, press and hold A to enter setting mode; hour will begin flashing.

2. Press D to decrease; press E to increase.

3. Press B to set and advance to next setting value.

4. Setting sequence is hour, minute, T1/T2.

5. Press A to save data and exit setting mode.

     NOTE: Alarm status will be ON automatically after exit the ALARM SETTING mode.

     No button operation for 30 seconds will auto-exit with changes saved, but alarm status OFF.

TIMER MODE

1. Press B to change to timer mode on 50 Lap Digital Models. On 10-30 Lap Digital

Models, press and hold E to change to timer mode.

2. Press C to start timer.

3. Press D to stop timer. Press and hold D to reset the timer when it is stopped.

4. Press E for next timer.

     NOTE: For 50 Lap Digital Models, there are 3 timers. For 10-30 Lap Digital Models, there are 5 timers.

Summary of Contents for ADIPOWER TR

Page 1: ...M SETTING 1 Press and hold C for 2 seconds to enter alarm setting 2 Press A to increase setting value Press C to decrease setting value 3 Press B to enter next setting field 4 Repeat steps 2 and 3 until desired time is selected 5 Press B to exit setting mode NOTE Alarm turns on automatically when exiting setting mode TIMER MODE TMR 1 Press C to enter timer mode 2 Press A to start stop timer 3 Pres...

Page 2: ...hronograph 2 Press C to view split time 3 Press B to toggle ELAPSED TIME AVG PACE DISTANCE 4 Press and hold B to toggle TOD PED modes 5 Press and hold C when timer is stopped for 5 sec to clear reset NOTE Maximum PACE conditions Time 23 hours 59 minutes 59 seconds and 99 milliseconds Pace 96 min mile or 60 min km Distance 124 2 miles 199 9 km NOTE The icons in will Blink with you are in each sub m...

Page 3: ...cute the following sequence 1 Turn all LCD Segments on 2 Generate a 1 second beep to confirm the Piezo test 3 Turn on lamp and all LCD Segments on 4 Wait for 2 seconds 5 Do not continue if all buttons are not released 6 Turn off all LCD Segments 7 Display the software code for 2 seconds 8 Display the software major version for 2 seconds 9 Display the software minor version for 2 seconds 10 Turn of...

Page 4: ...B to reset value to run chronograph 1 00s resolution for first 59 minutes and 59 99 seconds DURAMO FURANO URAHA QUESTRA ADIZERO BASIC SPRUNG BASIC QFL312BA QFL259BB QFL235FA QFL311BA QFL255CB QFL234EB QFL769CB TIME MODE 1 Press B to change modes 2 Press A for EL 3 Press C to select 12 24 hour format 4 Press D to enable disable hourly chime TIME SETTING 1 In time mode press and hold A for 2 seconds...

Page 5: ... 2 Press E to increase setting value Press D to decrease setting value 3 Press B to set and advance to next setting value 4 Setting sequence is hour minute second year month date 12 24 hour time date format 5 Press A to save data and exit setting mode ALARM MODE 1 Press B to change to alarm mode 2 Press D to toggle between alarms 1 and 2 3 Press E to toggle alarm on off ALARM SETTING 1 In alarm mo...

Page 6: ...0 Lap Digital Models press B to change to chronograph mode 2 Press C to start chronograph press C for lap when the chronograph is running 3 Press E to change views while chronograph is running Select between current lap total or both 4 Press D to stop chronograph when it is running press and hold D to reset to zero when the chronograph is stopped or press and hold A to save data to MY LOG NOTE On ...

Page 7: ...lashing 2 Press C to increase digits press and hold C for fast advance 3 Press A to advance to minutes 4 Press C to increase digits press and hold C for fast advance 5 Press B to exit setting mode and return to normal time display NOTE Alarm will sound for 60 seconds Press A to silence alarm or D for 5 minute snooze CHRONOGRAPH MODE 1 Press B one time to change to chronograph mode NOTE When in chr...

Page 8: ...mode 2 Press C to toggle alarm on off 3 Press D to toggle alarm 1 alarm 2 ALARM SETTING 1 In alarm mode press and hold B hour will begin flashing 2 Press C to increase digit press D to decrease digit Press and hold C or D for fast increment decrement 3 Press A to advance to next setting value 4 Setting sequence is hour minute normal time time zone 2 5 Press B to exit setting mode NOTE Alarm will a...

Page 9: ...0 5 Setting sequence is segment minute second 6 Press B to exit setting mode CHRONOGRAPH MODE 1 Press A to change to chronograph mode 2 Press E to start chronograph press D to stop chronograph 3 When the chronograph is stopped press and hold B to save data to MY LOG or press and hold D to reset chronograph to zero LAP COUNTING 1 Press E while the chronograph is running for lap counting up to 100 l...

Page 10: ...ss D to select desired game time 3 Game timers are 0 45 0 15 0 40 0 35 0 30 0 25 0 20 0 10 0 5 SET1 SET2 SET3 4 Press E to start game time 5 Press E again to stop game time Total game time will continue to run at the bottom 6 Press E again to start game time 7 Press C to flash stoppage time 8 Press D to stop the game time and total game time 9 When game time and total game time are stopped press a...

Page 11: ... and number of cycles up to 50 5 Press B to exit setting mode INTERVAL TIMER 1 In interval timer mode press and hold B to enter setting mode interval segment will begin flashing 2 Press C to increase digit press D to decrease digit Press and hold C or D for fast increment decrement 3 Press A to advance to next setting value 4 Repeat steps 2 and 3 until desired number of segments have been set up t...

Page 12: ... ATM 50 Bar 500 Meters Always set the crown in closed position the normal position Tighten screw lock crown completely To ensure water resistance exposure to hot water is not recommended Clean your watch with a soft cloth and water only Do not submerge your watch under water unless it is water rated see caseback After salt water use rinse watch under tap water and wipe dry with a soft cloth Metal ...