EDM Serial-to-Ethernet Converters
User Guide ver. 2.0 | 2021-09-01
Phone: +420 538 890 720
9
E-mail: [email protected]
Chapter 2. Operating the converter
Connection and installation
1.
Connect external 12V power to terminals G and VI of the terminal block XP2 or to connector 6P6C
(PWR).
2.
Connect the device to a local network (to a LAN hub or to a PC) using an Ethernet cable.
3.
Connect the equipment with RS-232 and/or RS-485 interfaces to the corresponding connectors
of the converter.
Attention! For the models of converters with isolated RS-485 interfaces, fix the terminal
resistor in the isolated PVC tube and connect its contacts to terminals “A” and “B”.
4.
To configure the converter through the web interface, launch a browser and enter into the address
line the default IP address of the device: 192.168.88.1.
5.
An authorization window will appear in the browser window after the successful connection.
Default authorization data:
username –
adgt
password –
adgt
.
The password can be changed in the General Settings section.
6.
Configure the parameters of Ethernet and serial interfaces. By default, the serial ports are in the
Disabled
state. Save the settings using the Setup button. List of configurable parameters and the
values of default parameter are available in section
Configuring the converter through the web
Attention! When changing the used Ethernet standard in the network, to which the
converter is connected, for example, from 10BASE-T to 100BASE-T and vice versa, restart
the converter for the correct operation of the device.
7.
Install the device. Depending on the type of mounting version, EDM106 converter can be placed
horizontally, on a flat surface, or mounted on a wall or on a DIN-rail (see sticker at the housing
for mounting options).
DIN-rail installation
For installation of converter onto a standard 35 mm DIN rail (H, V mounts), the delivery pack includes
a set of plastic mounts (brackets). Mounting kit H includes 2 brackets and 4 self-tapping screws.
Mounting kit V includes 1 bracket and 2 self-tapping screws. To install the converter on a DIN rail,
attach the brackets with self-tapping screws to the holes on the device housing (2 self-tapping screws
for one bracket).
Installation of converter with R-type mount is performed onto a standard 35 mm DIN rail using a
metal plate with a clamp on the device housing.
Wall mounting
The converter with T-type mount is installed onto the wall with use of the metal mounting plate and
two screws. Two plastic dowels with screws are included into the delivery pack.
Attention! After three incorrect attempts to enter the username/password, the access